{"id":1009,"date":"2013-12-02T08:30:10","date_gmt":"2013-12-02T13:30:10","guid":{"rendered":"http:\/\/www.constructionspecifier.com\/?p=1009"},"modified":"2017-01-18T14:54:51","modified_gmt":"2017-01-18T19:54:51","slug":"specifying-nfpa-285-testing","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/","title":{"rendered":"Specifying NFPA 285 testing"},"content":{"rendered":"<figure id=\"attachment_1012\" aria-describedby=\"caption-attachment-1012\" style=\"width: 241px\" class=\"wp-caption alignright\"><a title=\"Specifying NFPA 285 Testing\" href=\"http:\/\/www.constructionspecifier.com\/web-exclusive\/specifying-nfpa-285-testing\/\"><img loading=\"lazy\" decoding=\"async\" class=\"  wp-image-1012\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Apartment-b64FACC.jpg\" alt=\"bigstock-Apartment-b#64FACC\" width=\"241\" height=\"302\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Apartment-b64FACC.jpg 440w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Apartment-b64FACC-239x300.jpg 239w\" sizes=\"auto, (max-width: 241px) 100vw, 241px\" \/><\/a><figcaption id=\"caption-attachment-1012\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: small;\">Flames can blast through windows to climb along exterior walls\u2014a fact replicated by a National Fire Protection Association (NFPA) test.<\/span><br \/> <em><span class=\"img_c\">Photo \u00a9 BigStockPhoto\/Anne-Louise Quarfoth<\/span><\/em><\/figcaption><\/figure>\n<p><b>By Joseph Berchenko AIA, CSI, CCS<br \/>\n<\/b>For testing certain wall assemblies, the 2012 <i>International Building Code<\/i> (<i>IBC<\/i>) requires National Fire Protection Association (NFPA) 285, <i>Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-load-bearing Wall Assemblies Containing Combustible Components<\/i>. (That standard\u2019s title notwithstanding, the test is performed on both load-bearing and non-load-bearing wall assemblies.) Its successful completion demonstrates the ability of an exterior wall mockup to contain vertical and horizontal flame spread across the face and through the wall\u2019s core.<\/p>\n<p>Increased use of continuous insulation (ci) in building envelopes has meant enforcement of provisions requiring NFPA 285 testing has recently been stepped up, sparking discussion and concern on Internet bulletin boards and in professional journals. Specifiers must learn where and how to specify compliance with the standard. Additionally, designers must take care in matching details of project-specific wall assemblies to tested assemblies.<\/p>\n<p><b>Code requirements<br \/>\n<\/b><i>IBC<\/i> generally requires exterior walls in Types I, II, III, and IV construction be built of noncombustible materials. Combustible insulation and wall facings are allowed in some cases, but this is tightly regulated and often includes a requirement for NFPA 285 testing.<\/p>\n<p>Perhaps the most far-reaching mandate for NFPA 285 testing occurs in Chapter 26, which regulates plastics such as foam insulation. Testing is required for Section 2603.5.5. (<i>i.e.<\/i> exterior wall assemblies of Type I, II, III, and IV construction of any height containing foam-plastic insulation). Compliance with 2603.5 is also mandated in some cases by reference from Section 2612, which regulates the exterior use of fiber-reinforced polymer materials.<\/p>\n<p>NFPA 285 testing is also required for Section 1403 (<i>i.e.<\/i> exterior walls containing combustible water-resistive barriers in Types I, II, III, and IV construction when more than 12.2 m [40 ft] above grade).<\/p>\n<p>Since water-resistive barriers (WRBs) are a common feature of modern construction, this requirement impacts many high-rise buildings.<\/p>\n<p>During the 2012 Code Change Cycle, the National Institute of Building Sciences (NIBS) and the American Institute of Architects (AIA) jointly sought\u2014and were granted\u2014a modification clarifying and providing exceptions to the WRB rule that will appear in the 2015 edition of the <i>IBC<\/i>. (Attempts to modify Section 2603.5.5 were unsuccessful.) In 2015,<i> IBC <\/i>Section 1403.5 will include the following exceptions:<\/p>\n<ul>\n<li>noncombustible walls with WRBs concealed by a minimum thickness of certain weather coverings and not containing foam-plastic insulation;<\/li>\n<li>noncombustible walls with WRBs that contribute only minimally to fire loads (because the criteria for the exception are based on technical performance requirements like maximum peak heat release rate, total heat release, effective heat of combustion, and flame-spread and smoke-developed indexes, the final determination of which WRB materials qualify for the exception must be determined on a case-by-case basis); and<\/li>\n<li>windows, doors, and associated flashings.<\/li>\n<\/ul>\n<p>Other <i>IBC<\/i> sections also require NFPA 285 testing of the following individual components and systems:<\/p>\n<ul>\n<li>Section 1407.10.4\u2014metal composite materials (MCM) systems (<i>i.e.<\/i> composite wall panels with metal facings and thin plastic cores);<\/li>\n<li>Section 1408\u2014exterior insulation and finish systems (EIFS);<sup>1<\/sup><\/li>\n<li>Section 1409.10.4\u2014high-pressure laminate (HPL) systems for exterior use (<i>i.e.<\/i> plastic panels defined in the code as \u201chigh-pressure decorative exterior-grade compact laminates\u201d); and<\/li>\n<li>Section 1509.6.2\u2014panels part of an exterior wall system used to screen mechanical equipment mounted on roofs.<\/li>\n<\/ul>\n<p>Finally, <i>IBC<\/i> Section 718.2.6\u2019s Exception 3 allows fire blocking to be eliminated in concealed spaces behind exterior wall coverings when the wall covering has been tested according to NFPA 285.<\/p>\n<p><b>NFPA 285 testing<br \/>\n<\/b>The NFPA 285 test requires a wall assembly mockup spanning two stories with a test room on each floor. A single window opening is provided from the first story where a test burner is located. The burner is used to send a plume of flame through the window opening and up the exterior surface of the wall above. This simulates a fire that begins in an interior space, breeches a window, and spreads upward along the wall face. Such a scenario replicates a situation common in real-world fires.<\/p>\n<figure id=\"attachment_1013\" aria-describedby=\"caption-attachment-1013\" style=\"width: 341px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-1013 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Building-On64FACA.jpg\" alt=\"Protecting a building, its occupants, and its contents from fire is critical. Partially as a response to increased use of continuous insulation (ci) in building envelopes, enforcement of provisions requiring NFPA 285 testing has recently been stepped up.\" width=\"341\" height=\"227\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Building-On64FACA.jpg 440w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Building-On64FACA-300x199.jpg 300w\" sizes=\"auto, (max-width: 341px) 100vw, 341px\" \/><figcaption id=\"caption-attachment-1013\" class=\"wp-caption-text\">Protecting a building, its occupants, and its contents from fire is critical. Partially as a response to increased use of continuous insulation (ci) in building envelopes, enforcement of provisions requiring NFPA 285 testing has recently been stepped up.<br \/><span class=\"img_c\">Photo \u00a9 BigstockPhoto\/K. Mitu<\/span><\/figcaption><\/figure>\n<p>Two areas of mockups are of special concern:<\/p>\n<ul>\n<li>openings into wall cavities above window heads; and<\/li>\n<li>facing materials used on wall exteriors.<\/li>\n<\/ul>\n<p>For walls with cavities containing foam-plastic insulation or combustible WRBs, the protection of the cavity is paramount. In addition to the fire-resistive properties of the materials, successful test completion generally requires the wall cavity be protected by a continuous steel shelf angle and mineral-wool fire safing or other fire-blocking material. The configuration, thickness, and arrangement of fire-blocking materials for each test are detailed in the test report.<\/p>\n<p>In the case of combustible wall facings (<i>e.g.<\/i> EIFS, MCM, HPL, and foam-insulation-core panels), the materials must be sufficiently fire-resistive in and of themselves to withstand flame exposure for the duration of the test.<\/p>\n<p>Unfortunately, there is no third-party compilation of assembly tests, unlike the thousands of variations of fire-resistive wall assemblies tested and documented in the FM Global <i>Approval Guide<\/i>, Intertek ETL SEMCO <i>Directory of Listed Products<\/i>, and Underwriters Laboratories (UL) <i>Fire Resistance Directory<\/i>. However, numerous proprietary NFPA 285 tests have been performed by manufacturers, and may be accessed on their websites. To ensure compliance for wall assemblies, it is important designers study successful assembly tests and detail project-specific assemblies that exactly match tested assemblies.<\/p>\n<p>For large projects, consideration might be given to creating mockups of significant or unusual wall configurations and requiring preconstruction NFPA 285 laboratory testing. Although this is an expensive proposition, in projects of sufficient size it may help smooth permit review and will assure the owner the design provides adequate safety.<\/p>\n<p><b>Specification issues<br \/>\n<\/b>For Types I, II, III, and IV construction, requirements for NFPA 285 fire testing for individual products should be addressed in each section containing combustible exterior wall components. For example, NFPA 285 testing may be required in sections containing foam insulation, sheathing, foam-insulation-core panels, MCM panels, WRBs, and elsewhere as needed.<sup>2<\/sup><\/p>\n<p>It is tempting to simply add a general requirement in the Part 2 \u201cPerformance Requirements\u201d Article in each affected section calling for indicated assemblies to be NFPA 285-compliant. However, this is not only open-ended, but also, because it addresses the assembly, may imply the contractor is responsible for, or can alter, the assembly design. The specifier more commonly just wants to convey to the contractor a manufacturer has tested the wall assembly shown on the drawings with various acceptable products\u2014not that the contractor must take full responsibility for the wall\u2019s code compliance.<\/p>\n<p>For example, an insulation manufacturer may advertise an exterior wall assembly that has been successfully tested with a dozen different WRBs. The specifier may wish to instruct the contractor that any of those\u2014but only those\u2014water-restive barriers are acceptable. This author believes the best way to do this is add an NFPA 285 testing requirement in the water-resistive barrier section at that product type. For example:<\/p>\n<p><em>Fire Propagation Characteristics: Passes NFPA 285 testing as part of an approved assembly.<\/em><\/p>\n<p>Compliance of tested components is indicated in manufacturers\u2019 product data sheets, similar to other test compliances. A full copy of test results is not typically required by codes authorities, although the architect may request a copy of product data, tests, or other documentation in the \u201cInformational Submittals\u201d Article in Part 1 of each affected section, if desired.<\/p>\n<p>The contractor, who is assigned responsibility for securing the building permit by the American Institute of Architects (AIA) A201, <i>General Conditions of the Contract for Construction<\/i>, is responsible for submitting documentation to the code authority; it is not necessary to detail the contractor\u2019s submittals to codes offices in the technical specifications.<\/p>\n<p>Some combustible products and systems may have International Code Council Evaluation Service (ICC-ES) reports in which they are explicitly approved for use in or on exterior walls of buildings of Type I, II, III, and IV construction. Many codes authorities are willing to accept these reports as evidence of compliance.<\/p>\n<p><b>Conclusion<br \/>\n<\/b>Although the construction community must undergo a learning curve for NFPA 285 testing, protection of the health, safety, and welfare of building users remains the highest professional obligation. Strict code compliance is part and parcel of this obligation. Increased understanding and compliance with NFPA 285 code provisions will ultimately create better, safer buildings.<\/p>\n<p><b>Notes<br \/>\n<\/b><sup>1<\/sup> Although NFPA 285 is not specifically invoked by name, these systems are required to meet the performance characteristics required in ASTM E2568, <i>Standard Specification for PB Exterior Insulation and Finish Systems<\/i>. In its Table 3, this standard, in turn, mandates NFPA 285 compliance.<br \/>\n<sup>2<\/sup> In the case of EIFS, requiring compliance with ASTM E2568 is adequate.<\/p>\n<p><span style=\"color: #606060;\"><i><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1014\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/Berchenko_Joe-01_WEB-150x150.jpg\" alt=\"Berchenko_Joe-01_WEB\" width=\"100\" height=\"100\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/Berchenko_Joe-01_WEB-150x150.jpg 150w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/Berchenko_Joe-01_WEB-50x50.jpg 50w\" sizes=\"auto, (max-width: 100px) 100vw, 100px\" \/>Joseph Berchenko AIA, CSI, CCS, is the assistant director of architectural specifications for ARCOM MasterSpec,<\/i> <i>where he supervises the maintenance and updating of more than 400 architectural\/structural\/engineering for the master guide specification system. A licensed architect with 35 of years of experience in the construction industry, Berchenko served as a commercial plans examiner for Lincoln, Nebraska\u2019s Department of Building and Safety before becoming a specification writer. He is a past-president of CSI\u2019s DC Metropolitan Chapter. <\/i><\/span><span style=\"color: #606060;\"><i>He can be contacted at <a href=\"mailto:jberchenko@arcomnet.com\">jberchenko@arcomnet.com<\/a><\/i>.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>For testing certain wall assemblies, the 2012 International Building Code (IBC) requires National Fire Protection Association (NFPA) 285, Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-load-bearing Wall Assemblies Containing Combustible Components.<\/p>\n","protected":false},"author":1,"featured_media":1012,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,12,179,449,187,264,489,460],"tags":[83,60,84,1877,70,81,82],"class_list":["post-1009","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-web-exclusive","category-masterformat","category-uniformat","category-07-00-00-thermal-and-moisture-protection","category-07-20-00-thermal-protection","category-b2010exterior-walls","category-b20exterior-vertical-enclosures","tag-continuous-insulation","tag-fire","tag-foam","tag-ibc","tag-insulation","tag-nfpa","tag-nfpa-285","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Specifying NFPA 285 testing - The Construction Specifier<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Specifying NFPA 285 testing - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"For testing certain wall assemblies, the 2012 International Building Code (IBC) requires National Fire Protection Association (NFPA) 285, Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-load-bearing Wall Assemblies Containing Combustible Components.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2013-12-02T13:30:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-01-18T19:54:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Apartment-b64FACC.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"440\" \/>\n\t<meta property=\"og:image:height\" content=\"550\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"eyetee\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"eyetee\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/\"},\"author\":{\"name\":\"eyetee\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/27a8ccc930cede4eeb25c6a121d87bc5\"},\"headline\":\"Specifying NFPA 285 testing\",\"datePublished\":\"2013-12-02T13:30:10+00:00\",\"dateModified\":\"2017-01-18T19:54:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/\"},\"wordCount\":1539,\"commentCount\":3,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2013\\\/11\\\/bigstock-Apartment-b64FACC.jpg\",\"keywords\":[\"continuous insulation\",\"fire\",\"foam\",\"IBC\",\"Insulation\",\"NFPA\",\"NFPA 285\"],\"articleSection\":[\"Features\",\"Web Exclusive\",\"MasterFormat\",\"UniFormat\",\"07 00 00 Thermal and Moisture Protection\",\"07 20 00 Thermal Protection\",\"B2010\u2212Exterior Walls\",\"B20\u2212Exterior Vertical Enclosures\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/\",\"name\":\"Specifying NFPA 285 testing - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2013\\\/11\\\/bigstock-Apartment-b64FACC.jpg\",\"datePublished\":\"2013-12-02T13:30:10+00:00\",\"dateModified\":\"2017-01-18T19:54:51+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2013\\\/11\\\/bigstock-Apartment-b64FACC.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2013\\\/11\\\/bigstock-Apartment-b64FACC.jpg\",\"width\":440,\"height\":550},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-nfpa-285-testing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Specifying NFPA 285 testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/27a8ccc930cede4eeb25c6a121d87bc5\",\"name\":\"eyetee\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g\",\"caption\":\"eyetee\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/eyetee\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Specifying NFPA 285 testing - The Construction Specifier","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/","og_locale":"en_US","og_type":"article","og_title":"Specifying NFPA 285 testing - The Construction Specifier","og_description":"For testing certain wall assemblies, the 2012 International Building Code (IBC) requires National Fire Protection Association (NFPA) 285, Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-load-bearing Wall Assemblies Containing Combustible Components.","og_url":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/","og_site_name":"The Construction Specifier","article_published_time":"2013-12-02T13:30:10+00:00","article_modified_time":"2017-01-18T19:54:51+00:00","og_image":[{"width":440,"height":550,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Apartment-b64FACC.jpg","type":"image\/jpeg"}],"author":"eyetee","twitter_card":"summary_large_image","twitter_misc":{"Written by":"eyetee","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/"},"author":{"name":"eyetee","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/27a8ccc930cede4eeb25c6a121d87bc5"},"headline":"Specifying NFPA 285 testing","datePublished":"2013-12-02T13:30:10+00:00","dateModified":"2017-01-18T19:54:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/"},"wordCount":1539,"commentCount":3,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Apartment-b64FACC.jpg","keywords":["continuous insulation","fire","foam","IBC","Insulation","NFPA","NFPA 285"],"articleSection":["Features","Web Exclusive","MasterFormat","UniFormat","07 00 00 Thermal and Moisture Protection","07 20 00 Thermal Protection","B2010\u2212Exterior Walls","B20\u2212Exterior Vertical Enclosures"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/","url":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/","name":"Specifying NFPA 285 testing - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Apartment-b64FACC.jpg","datePublished":"2013-12-02T13:30:10+00:00","dateModified":"2017-01-18T19:54:51+00:00","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Apartment-b64FACC.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/11\/bigstock-Apartment-b64FACC.jpg","width":440,"height":550},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/specifying-nfpa-285-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"Specifying NFPA 285 testing"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/27a8ccc930cede4eeb25c6a121d87bc5","name":"eyetee","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g","caption":"eyetee"},"url":"https:\/\/www.constructionspecifier.com\/author\/eyetee\/"}]}},"views":24882,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/1009","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=1009"}],"version-history":[{"count":14,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/1009\/revisions"}],"predecessor-version":[{"id":25445,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/1009\/revisions\/25445"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/1012"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=1009"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=1009"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=1009"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}