{"id":108650,"date":"2020-03-19T10:03:29","date_gmt":"2020-03-19T14:03:29","guid":{"rendered":"https:\/\/www.constructionspecifier.com\/?p=108650"},"modified":"2020-05-17T13:29:26","modified_gmt":"2020-05-17T17:29:26","slug":"a-rational-approach-to-ceiling-product-evaluation","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/","title":{"rendered":"A rational approach to ceiling product evaluation"},"content":{"rendered":"<p><strong>by Michael Chusid, RA, FCSI<\/strong><\/p>\n<p>&nbsp;<\/p>\n<figure id=\"attachment_108657\" aria-describedby=\"caption-attachment-108657\" style=\"width: 300px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-108657 size-medium\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar-300x200.jpg\" alt=\"Thermoformed and mineral fiber acoustic panels are combined to add visual interest to the expansive ceiling of the new dining hall at Mount Holyoke College, designed by Bergmeyer. Thermoformed panels could be installed over food preparation areas because they are washable and impervious. Photo \u00a9 Chun Y Lai Photography\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar-500x333.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar-768x512.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-108657\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">Thermoformed and mineral fiber acoustic panels are combined to add visual interest to the expansive ceiling of the new dining hall at Mount Holyoke College, designed by Bergmeyer. Thermoformed panels could be installed over food preparation areas because they are washable and impervious.<\/span><em><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><br \/>Photo \u00a9 Chun Y Lai Photography<\/span><\/em><\/figcaption><\/figure>\n<p>Despite widespread perception that architects and designers are fearless innovators, many, in the author\u2019s opinion, are quite resistant to change. When a product works reasonably well, building professionals tend to stick with it until strong evidence justifies a change.<\/p>\n<p>This article presents a rational investigation comparing acoustic ceiling products made from mineral fiber with thermoformed rigid vinyl types. While manufacturer reputation, economics, availability, and similar factors are important considerations, a rational investigation must look at test data gathered in accordance with industry standards. While performance is not everything, without it, there is nothing.<\/p>\n<figure id=\"attachment_108655\" aria-describedby=\"caption-attachment-108655\" style=\"width: 300px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-FriabilityTest-Before-After-Edit.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-108655\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-FriabilityTest-Before-After-Edit-300x151.jpg\" alt=\"Figure 1: Mineral fiber panels show erosion due to testing for friability, as per ASTM C367, Standard Test Methods for Strength Properties of Prefabricated Architectural Acoustical Tile or Lay-in Ceiling Panels. Thermoformed panels (right) do not exhibit any signs of damage. Photos \u00a9 PRI Construction Materials Technologies LLC\" width=\"300\" height=\"151\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-FriabilityTest-Before-After-Edit-300x151.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-FriabilityTest-Before-After-Edit-500x251.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-FriabilityTest-Before-After-Edit-768x386.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-FriabilityTest-Before-After-Edit.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-108655\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><strong>Figure 1:<\/strong> Mineral fiber panels show erosion due to testing for friability, as per ASTM C367, <em>Standard Test Methods for Strength Properties of Prefabricated Architectural Acoustical Tile or Lay-in Ceiling Panels<\/em>. Thermoformed panels (right) do not exhibit any signs of damage.<\/span><br \/><em><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">Photos \u00a9 PRI Construction Materials Technologies LLC<\/span><\/em><\/figcaption><\/figure>\n<p>The basis for the investigation is testing by independent laboratories using recognized industry standards. Committees tasked with developing standards comprise individuals who are active in and knowledgeable about the subject matter. Their work is open to public review and commented on and honed through periodic revision. A document is not issued as a standard until a consensus is reached that it provides a meaningful tool that can be applied throughout an industry.<\/p>\n<p>Some standards used to evaluate ceiling materials are well-known and frequently cited in product literature and construction specifications. For example, ASTM C423, <em>Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method<\/em>, and ASTM E84, <em>Standard Test Method for Surface Burning Characteristics of Building Materials<\/em>. Other standards, including those for strength properties and stain resistance, are less familiar but provide valuable insight for material selection.<\/p>\n<figure id=\"attachment_108656\" aria-describedby=\"caption-attachment-108656\" style=\"width: 300px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MineralFiberStrengthTest-Sag-Annotated.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-108656\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MineralFiberStrengthTest-Sag-Annotated-300x231.jpg\" alt=\"Figure 2: Ceiling panels can sag when exposed to elevated humidity. Many school buildings, for example, have elevated humidity during summer breaks when air-conditioning systems are shut down to conserve energy.\" width=\"300\" height=\"231\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MineralFiberStrengthTest-Sag-Annotated-300x231.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MineralFiberStrengthTest-Sag-Annotated-500x386.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MineralFiberStrengthTest-Sag-Annotated-768x592.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MineralFiberStrengthTest-Sag-Annotated.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-108656\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><strong>Figure 2:<\/strong> Ceiling panels can sag when exposed to elevated humidity. Many school buildings, for example, have elevated humidity during summer breaks <\/span><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">when air-conditioning systems are shut down to conserve energy.<\/span><\/figcaption><\/figure>\n<p><strong>Strength properties<\/strong><\/p>\n<p>ASTM C367, <em>Standard Test Methods for Strength Properties of Prefabricated Architectural Acoustical Tile or Lay-in Ceiling Panels<\/em>, contains procedures to test acoustic ceiling tiles and lay-in ceiling panels for hardness, friability, sag, and traverse strength. Its preface says that some \u201cmaterials used for absorbing sound generally have a porous, low-density structure. In comparison with many building materials, they are relatively fragile. Materials are available that possess adequate strength and stability and at the same time provide good sound absorption.\u201d<\/p>\n<p><em>Hardness<\/em><\/p>\n<p>This test corresponds with a panel\u2019s resistance to impact or indentation, measured by recording the force required to depress a 50-mm (2-in.) diameter penetrator to a depth of 6 mm (<sup>1<\/sup>\/<sub>4<\/sub>\u00a0in.) into the panel. Thermoformed panels are too thin to test singly, so multiple layers of the material were stacked to enable assessment. The results are not representative of actual conditions of use, but indicate vinyl is significantly harder than mineral fiber.<\/p>\n<p><em>Friability<\/em><\/p>\n<p>Twelve small squares of the material being tested are placed, along with 24 small wood cubes, in a wood box, then tumbled at prescribed speed for two cycles of 10 minutes duration. The specimens are weighed after each cycle and the percent of mass lost through abrasion or breakage is calculated. Products losing the most mass are more friable (Figure 1).<\/p>\n<p>ASTM C367 says, \u201cProducts that are friable and soft will erode considerably when subjected to rough treatment.\u201d<\/p>\n<p>Experience indicates friable products erode considerably even due to ordinary treatment.<\/p>\n<p>Further, \u201cthe friability test measures the susceptibility of an acoustical product to edge and corner damage sustained during shipping, handling, and installing.\u201d<\/p>\n<p>Friability, however, may also relate to release of airborne fibers due to normal building vibrations.<!--nextpage--><\/p>\n<figure id=\"attachment_108661\" aria-describedby=\"caption-attachment-108661\" style=\"width: 225px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/IMG_0137-Edit.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-108661\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/IMG_0137-Edit-225x300.jpg\" alt=\"Figure 3: Testing demonstrates the vulnerability of panels to breakage during delivery, storage, and installation. Even routine handling can damage \" width=\"225\" height=\"300\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/IMG_0137-Edit-225x300.jpg 225w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/IMG_0137-Edit-375x500.jpg 375w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/IMG_0137-Edit.jpg 600w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/a><figcaption id=\"caption-attachment-108661\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><strong>Figure 3:<\/strong> Testing demonstrates the vulnerability of panels to breakage during delivery, storage, and installation. Even routine handling can damage <\/span><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">low-strength and friable materials.<\/span><br \/><em><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">Photo \u00a9 Michael Chusid<\/span><\/em><\/figcaption><\/figure>\n<p>The impact of friability goes beyond the panel appearance and durability. The particles released by mineral fiber products may contain crystalline silica. One major manufacturer\u2019s safety data sheet cautions, \u201cBe certain the work site is well ventilated and avoid breathing dust. Exposures to respirable crystalline silica\u2026must be determined by workplace hygiene testing. Prolonged and repeated exposure to airborne free respirable crystalline silica can result in lung disease (<em>i.e.<\/em> silicosis) and\/or lung cancer\u2026\u201d Since particles may also be combustible, the same safety data sheet warns, \u201cDust deposits should not be allowed to accumulate on surfaces, as these may form an explosive mixture\u2026\u201d<\/p>\n<p><em>Sag<\/em><\/p>\n<p>After panels are conditioned to a stable ambient temperature and humidity, they are exposed to elevated temperature and humidity, and any of the humidity-induced sag is recorded. The panels are then returned to the initial temperature and humidity, and the recovery sag is recorded. In most cases, the recovery sag represents a permanent deformation. The results of exposure to ambient humidity also suggest how a product responds to moisture exposure via leaks, condensation, and other sources of liquid water (Figure 2).<\/p>\n<p><em>Transverse strength<\/em><\/p>\n<figure id=\"attachment_108653\" aria-describedby=\"caption-attachment-108653\" style=\"width: 300px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/ASTM-C367-SummaryTable-Wide.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-108653\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/ASTM-C367-SummaryTable-Wide-300x270.jpg\" alt=\"Figure 4: ASTM C367 enables specifiers to compare various acoustic ceiling products. As classified by ASTM E1264, Standard Classification for Acoustical Ceiling Products, the tested mineral fiber panels are Type III, Form 1, Pattern E I and the thermoformed panels are Type XX (thermoformed rigid vinyl), C E Z (shallow coffer). Test results will vary depending on the product manufacturer. Images courtesy Ceilume\" width=\"300\" height=\"270\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/ASTM-C367-SummaryTable-Wide-300x270.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/ASTM-C367-SummaryTable-Wide-500x450.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/ASTM-C367-SummaryTable-Wide-768x691.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/ASTM-C367-SummaryTable-Wide.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-108653\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><strong>Figure 4:<\/strong> ASTM C367 enables specifiers to compare various acoustic ceiling products. As classified by ASTM E1264, <em>Standard Classification for Acoustical Ceiling Products<\/em>, the tested mineral fiber panels are Type III, Form 1, Pattern E I and the thermoformed panels are Type XX (thermoformed rigid vinyl), C E Z (shallow coffer). Test results will vary depending on the product manufacturer.<\/span><br \/><em><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">Images courtesy Ceilume<\/span><\/em><\/figcaption><\/figure>\n<p>Panels are tested in a hydraulic machine, and the load is noted at which the panel breaks or yields and is unable to carry additional loads. The modulus of rupture (flexural strength) is then calculated. A larger modulus indicates greater strength and break resistance.<\/p>\n<p>According to ASTM C367, \u201cPerformance characteristics in the handling, shipping, and installing of acoustical tiles or panels are often predicted by strength testing.\u201d<\/p>\n<p>Breakage can also occur during maintenance activities when panels may be moved for above-ceiling access. While new construction employs trained installers, maintenance is frequently performed by untrained tradespersons who are more likely to cause breakage (Figure 3).<\/p>\n<p><em>Discussion<\/em><\/p>\n<figure id=\"attachment_108735\" aria-describedby=\"caption-attachment-108735\" style=\"width: 300px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-108735\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-5-300x149.jpg\" alt=\"Figure 5: Commonly used mineral fiber acoustic ceiling panels are difficult to clean and can disfigure. Thermoformed acoustic ceiling panels \" width=\"300\" height=\"149\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-5-300x149.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-5-500x249.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-5.jpg 742w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-108735\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><strong>Figure 5:<\/strong> Commonly used mineral fiber acoustic ceiling panels are difficult to clean and can disfigure. Thermoformed acoustic ceiling panels are stain resistant, and grime can be removed with simple washing.<\/span><\/figcaption><\/figure>\n<p>Thermoformed panel strength properties are at least an order of magnitude superior to the mineral fiber panels in all categories. The results of the tests are summarized in Figure 4.<\/p>\n<p><strong>Stain resistance<\/strong><\/p>\n<p>ASTM D1308, <em>Standard Test Method for Effect of Household Chemicals on Clear and Pigmented Organic <\/em><em>Finishes<\/em>, \u201ccovers determination of the effect of household chemicals\u2026 resulting in any objectionable alteration in the surface, such as discoloration, change in gloss, blistering, softening, swelling, loss of adhesion, or special phenomena.\u201d<\/p>\n<p>While developed to test coatings with household chemicals, the test methodology is frequently applied to diverse types of interior finishes and with chemicals used in industrial, healthcare, and commercial facilities.<\/p>\n<p>Interior finishes often \u2018ugly out\u2019 before wearing out. For example, many acoustic ceiling panels are difficult to clean and end up landfilled when they become unsightly. In contrast, stain-resistant and cleanable ceiling panels offer significant advantages in sustainability, economics, and life-cycle performance (Figure 5).<\/p>\n<p>Ceilings are the part of a room in the least physical contact with occupants, yet they are exposed to dirt, grime, and stains from a variety of sources. Air currents from diffusers or ordinary convection carry dust, soot, and aerosols onto ceilings. Everyday substances splash, squirt, or spray upward. Water from leaks, spills, and condensation cause stains and mold on common mineral fiber acoustic ceilings. Panels in suspended ceilings can also get dirty when handled for maintenance access above the ceiling. Despite this, reliable data on ceiling stainability and cleanability has been difficult to find.<!--nextpage--><\/p>\n<figure id=\"attachment_108664\" aria-describedby=\"caption-attachment-108664\" style=\"width: 248px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/StainTestMatrix-ShortForm-Sanitized.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-108664\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/StainTestMatrix-ShortForm-Sanitized-248x300.jpg\" alt=\"Figure 6: Ceiling panels were tested in accordance with ASTM D1308, Effect of Household Chemicals on Clear and Pigmented Organic Finishes. As classified by ASTM E1264, the tested mineral fiber panels are Type III, Form 1, Pattern E I and the thermoformed panels are Type XX (thermoformed rigid vinyl), C E Z (shallow coffer). Test results will vary depending on the product manufacturer.\" width=\"248\" height=\"300\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/StainTestMatrix-ShortForm-Sanitized-248x300.jpg 248w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/StainTestMatrix-ShortForm-Sanitized-413x500.jpg 413w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/StainTestMatrix-ShortForm-Sanitized.jpg 661w\" sizes=\"auto, (max-width: 248px) 100vw, 248px\" \/><\/a><figcaption id=\"caption-attachment-108664\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><strong>Figure 6:<\/strong> Ceiling panels were tested in accordance with ASTM D1308, <em>Effect of Household Chemicals on Clear and Pigmented Organic Finishes<\/em>. As classified by ASTM E1264, the tested mineral fiber panels are Type III, Form 1, Pattern E I and the thermoformed panels are Type XX (thermoformed rigid vinyl), C E Z (shallow coffer). Test results will vary depending on the product manufacturer.<\/span><\/figcaption><\/figure>\n<p><em>Test methodology<\/em><\/p>\n<p>Samples were exposed to 14 common staining agents including coffee, red wine, yellow mustard, ketchup, vegetable oil, bleach, povidone iodine, hydrogen peroxide, light machine oil, baking soda solution, vinegar, two types of swimming pool chlorine, and permanent marker. The laboratory compared one of the most widely used white mineral fiber acoustic panels against four colors of thermoformed acoustic panels.<\/p>\n<p>Each staining agent was placed on a specimen panel and allowed to sit overnight. After being cleaned in accordance with the standard, specimens were examined visually, photographed, and the findings are summarized in Figure 6.<\/p>\n<p><em>Results<\/em><\/p>\n<p>The mineral fiber panels showed \u2018significant stains\u2019 from all the food products, povidone iodine, calcium hypochlorite, and light machine oil. They had faint stains from bleach and one of the chloride products. The only staining agent they resisted was hydrogen peroxide.<\/p>\n<figure id=\"attachment_108736\" aria-describedby=\"caption-attachment-108736\" style=\"width: 192px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-7.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-108736\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-7-192x300.jpg\" alt=\"Figure 7: Mineral fiber acoustical panels were disfigured by almost all other staining agents tested, including this specimen tested with red wine. Thermoformed acoustic panels were resistant to all but a few of the agents tested. Photos \u00a9 National Testing Systems\" width=\"192\" height=\"300\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-7-192x300.jpg 192w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-7.jpg 293w\" sizes=\"auto, (max-width: 192px) 100vw, 192px\" \/><\/a><figcaption id=\"caption-attachment-108736\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><strong>Figure 7:<\/strong> Mineral fiber acoustical panels were disfigured by almost all other staining agents tested, including this specimen tested with red wine. Thermoformed acoustic panels were resistant to all but a few of the agents tested.<\/span><br \/><em><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">Photos \u00a9 National Testing Systems<\/span><\/em><\/figcaption><\/figure>\n<p>In contrast, thermoformed acoustic ceiling panels proved stain-resistant with either zero or only faint stains from all the agents tested. Permanent marker is the only exception to this observation as it stained all specimens. White showed no staining with any of the 13 other substances. Latte had only \u2018very faint\u2019 stains from baking soda, coffee, and bleach\u2014the laboratory noted these \u201cappear as very slight discoloration of the surface where the substance was applied. They are difficult to notice at first glance, and require an angled view under lighting to be seen.\u201d Faux metal and wood finishes resisted everything except three harsh chemical solutions: bleach, hydrogen peroxide, and calcium hypochlorite (Figure 7).<\/p>\n<p><em>Discussion<\/em><\/p>\n<p>Mineral fiber panels have porous or fissured surfaces that are vital to their acoustic performance, yet they provide locations through which stains can enter into a panel and become difficult to dislodge. Most mineral fiber panels can be damaged by water or liquid, so there is no effective way to wash them. Further, their edges and corners are fragile and prone to damage when panels are handled or removed for cleaning.<\/p>\n<figure id=\"attachment_108737\" aria-describedby=\"caption-attachment-108737\" style=\"width: 300px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-8.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-108737\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-8-300x107.jpg\" alt=\"Figure 8: Water can stain mineral fiber panels by leaching contaminants to the surface and supporting the growth of mold. Thermoformed acoustic ceiling panels are impervious to water damage and water-borne stains. Images courtesy Ceilume\" width=\"300\" height=\"107\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-8-300x107.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-8-500x179.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Figure-8.jpg 634w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-108737\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><strong>Figure 8:<\/strong> Water can stain mineral fiber panels by leaching contaminants to the surface and supporting the growth of mold. Thermoformed acoustic ceiling panels are impervious to water damage and water-borne stains.<\/span><br \/><em><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">Images courtesy Ceilume<\/span><\/em><\/figcaption><\/figure>\n<p>Thermoformed panels are made from rigid vinyl that is impervious to moisture and easily cleaned\u2014factors that make them acceptable for use in hygienic environments such as food handling and healthcare areas. They can be cleaned by brushing, vacuuming, or with water or common household cleaners. They are durable enough to be taken down, cleaned, and replaced without damage (Figure 8).<\/p>\n<p><strong>Other considerations<\/strong><\/p>\n<p>Specifiers must balance many considerations when selecting appropriate products for a building, and sometimes strength and stain resistance are not the primary drivers. Some mineral fiber panels, for example, can contribute to the fire-resistance of floor-ceiling assemblies or offer superior noise-reduction properties. Yet, strength and stain resistance impact product durability, the service life, and building sustainability and resilience, and should be considered as part of a holistic approach to design.<\/p>\n<p>When interpreting the test results based on standards, ASTM cautions, \u201cNot all of the tests described in these test methods are necessary to evaluate any particular product for a specific use. In each instance, it is necessary to determine which properties are required. Properties determined by these test methods reflect the performance of the materials under the specific conditions of the test, and do not necessarily indicate performance under conditions other than those specified herein. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.\u201d<\/p>\n<p><em><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Chusid-Headshot-2015-02-Edit-Edit.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-108659 alignleft\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Chusid-Headshot-2015-02-Edit-Edit-240x300.jpg\" alt=\"\" width=\"38\" height=\"47\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Chusid-Headshot-2015-02-Edit-Edit-240x300.jpg 240w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Chusid-Headshot-2015-02-Edit-Edit-399x500.jpg 399w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Chusid-Headshot-2015-02-Edit-Edit.jpg 639w\" sizes=\"auto, (max-width: 38px) 100vw, 38px\" \/><\/a>Michael Chusid, RA, FCSI, is a frequent contributor to <\/em>The Construction Specifier<em>, and a consultant to building product manufacturers. He can be reached at <a href=\"http:\/\/www.chusid.com\" target=\"_blank\" rel=\"noopener noreferrer\">www.chusid.com<\/a>.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Designers and specifiers have a variety of ceiling materials, such as mineral fiber and thermoformed rigid vinyl, to choose from. Yet, product selection requires a rational investigation of the test data supporting manufacturer claims.<\/p>\n","protected":false},"author":13542,"featured_media":108657,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,179,449,181,224,189,283,505,462,511,463],"tags":[4966,5757,4971,5758,5252,936],"class_list":["post-108650","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-masterformat","category-uniformat","category-01-00-00-general-requirements","category-01-40-00-quality-requirements","category-09-00-00-finishes","category-09-50-00-ceilings","category-c1070suspended-ceiling-construction","category-c10interior-construction","category-c2050ceiling-finishes","category-c20interior-finishes","tag-4966","tag-acoustic-ceiling","tag-divisions-01","tag-mineral-fiber-panels","tag-thermoformed-panels","tag-vinyl","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>A rational approach to ceiling product evaluation - The Construction Specifier<\/title>\n<meta name=\"description\" content=\"Designers and specifiers have a variety of ceiling materials, yet, product selection requires a rational investigation of the test data supporting manufacturer claims.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/\" \/>\n<link rel=\"next\" href=\"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A rational approach to ceiling product evaluation - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Designers and specifiers have a variety of ceiling materials, yet, product selection requires a rational investigation of the test data supporting manufacturer claims.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-19T14:03:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-05-17T17:29:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"533\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"sadia_badhon\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"sadia_badhon\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/\"},\"author\":{\"name\":\"sadia_badhon\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/991f070de813fbb84c1b570da5fdea1e\"},\"headline\":\"A rational approach to ceiling product evaluation\",\"datePublished\":\"2020-03-19T14:03:29+00:00\",\"dateModified\":\"2020-05-17T17:29:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/\"},\"wordCount\":2100,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg\",\"keywords\":[\"09\",\"Acoustic ceiling\",\"Divisions 01\",\"Mineral fiber panels\",\"Thermoformed panels\",\"Vinyl\"],\"articleSection\":[\"Features\",\"MasterFormat\",\"UniFormat\",\"01 00 00 General Requirements\",\"01 40 00 Quality Requirements\",\"09 00 00 Finishes\",\"09 50 00 Ceilings\",\"C1070\u2212Suspended Ceiling Construction\",\"C10\u2212Interior Construction\",\"C2050\u2212Ceiling Finishes\",\"C20\u2212Interior Finishes\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/\",\"name\":\"A rational approach to ceiling product evaluation - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg\",\"datePublished\":\"2020-03-19T14:03:29+00:00\",\"dateModified\":\"2020-05-17T17:29:26+00:00\",\"description\":\"Designers and specifiers have a variety of ceiling materials, yet, product selection requires a rational investigation of the test data supporting manufacturer claims.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-rational-approach-to-ceiling-product-evaluation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg\",\"width\":800,\"height\":533,\"caption\":\"Photo \u00a9 Chun Y Lai Photography\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/991f070de813fbb84c1b570da5fdea1e\",\"name\":\"sadia_badhon\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1d3ff700dcb6c77e12f7e53bf9f893c95d83582cc6605956286c2e143cffaf9c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1d3ff700dcb6c77e12f7e53bf9f893c95d83582cc6605956286c2e143cffaf9c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1d3ff700dcb6c77e12f7e53bf9f893c95d83582cc6605956286c2e143cffaf9c?s=96&d=mm&r=g\",\"caption\":\"sadia_badhon\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/sadia_badhon\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"A rational approach to ceiling product evaluation - The Construction Specifier","description":"Designers and specifiers have a variety of ceiling materials, yet, product selection requires a rational investigation of the test data supporting manufacturer claims.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/","next":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/2\/","og_locale":"en_US","og_type":"article","og_title":"A rational approach to ceiling product evaluation - The Construction Specifier","og_description":"Designers and specifiers have a variety of ceiling materials, yet, product selection requires a rational investigation of the test data supporting manufacturer claims.","og_url":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/","og_site_name":"The Construction Specifier","article_published_time":"2020-03-19T14:03:29+00:00","article_modified_time":"2020-05-17T17:29:26+00:00","og_image":[{"width":800,"height":533,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg","type":"image\/jpeg"}],"author":"sadia_badhon","twitter_card":"summary_large_image","twitter_misc":{"Written by":"sadia_badhon","Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/"},"author":{"name":"sadia_badhon","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/991f070de813fbb84c1b570da5fdea1e"},"headline":"A rational approach to ceiling product evaluation","datePublished":"2020-03-19T14:03:29+00:00","dateModified":"2020-05-17T17:29:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/"},"wordCount":2100,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg","keywords":["09","Acoustic ceiling","Divisions 01","Mineral fiber panels","Thermoformed panels","Vinyl"],"articleSection":["Features","MasterFormat","UniFormat","01 00 00 General Requirements","01 40 00 Quality Requirements","09 00 00 Finishes","09 50 00 Ceilings","C1070\u2212Suspended Ceiling Construction","C10\u2212Interior Construction","C2050\u2212Ceiling Finishes","C20\u2212Interior Finishes"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/","url":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/","name":"A rational approach to ceiling product evaluation - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg","datePublished":"2020-03-19T14:03:29+00:00","dateModified":"2020-05-17T17:29:26+00:00","description":"Designers and specifiers have a variety of ceiling materials, yet, product selection requires a rational investigation of the test data supporting manufacturer claims.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/a-rational-approach-to-ceiling-product-evaluation\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2020\/03\/Ceilume-MountHolyokeCollege-DiningCommons-BreakfastBar.jpg","width":800,"height":533,"caption":"Photo \u00a9 Chun Y Lai Photography"},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/991f070de813fbb84c1b570da5fdea1e","name":"sadia_badhon","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/1d3ff700dcb6c77e12f7e53bf9f893c95d83582cc6605956286c2e143cffaf9c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/1d3ff700dcb6c77e12f7e53bf9f893c95d83582cc6605956286c2e143cffaf9c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1d3ff700dcb6c77e12f7e53bf9f893c95d83582cc6605956286c2e143cffaf9c?s=96&d=mm&r=g","caption":"sadia_badhon"},"url":"https:\/\/www.constructionspecifier.com\/author\/sadia_badhon\/"}]}},"views":11534,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/108650","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/13542"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=108650"}],"version-history":[{"count":5,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/108650\/revisions"}],"predecessor-version":[{"id":112630,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/108650\/revisions\/112630"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/108657"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=108650"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=108650"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=108650"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}