{"id":13840,"date":"2015-12-23T12:52:18","date_gmt":"2015-12-23T17:52:18","guid":{"rendered":"http:\/\/www.constructionspecifier.com\/?p=13840"},"modified":"2016-11-24T11:40:49","modified_gmt":"2016-11-24T16:40:49","slug":"a-reader-comments-on-fiber-cement-feature","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/","title":{"rendered":"A reader comments on fiber cement feature"},"content":{"rendered":"<p>In our September 2015 issue, we published the article, \u201c<a href=\"http:\/\/www.constructionspecifier.com\/fiber-cement-panels-as-rainscreens\/\" target=\"_blank\">Fiber Cement Panels as Rainscreens<\/a>,\u201d by Carolina Albano. One reader, Richard Keleher (RJKeleher Architect), wrote to offer his thoughts about the piece and the subject matter in general. We shared with the author, who thanked him for his comments, and present it here:<\/p>\n<p><span style=\"font-family: georgia,palatino,serif;\">On <a href=\"http:\/\/www.kenilworth.com\/publications\/cs\/de\/201509\/files\/96.html\" target=\"_blank\">page 96<\/a>, the author writes that one of the required components of a rainscreen wall assembly is \u201ca few inches of air chamber or cavity separating the cladding from the support wall, reducing splashing and capillary moisture transfer.\u201d However, she should make it clear the 3\/8 or 7\/16 in. is enough. In this section, Albano also refers to \u201clarge, protected openings (<em>e.g.<\/em> vents or weep holes) positioned at the top \u2026 of the wall promote convective airflow,\u201d but this is not necessarily the case, especially for pressure-equalized rainscreens (PERs). Nowhere in the article does she note the importance and difficulty of protecting those openings from wind-driven rain.<\/span><\/p>\n<p><span style=\"font-family: georgia,palatino,serif;\">Later in the article, the author says, \u201cThe key to an efficient PER lies in the ability to control the airflow,\u201d to which I would add, \u201cand, more importantly, to baffle the water while letting air in.\u201d Along these same lines, Albano\u00a0 suggests the structural designer or engineer would determine the number and size of these breaks, but there is no mention of the importance of baffling these breaks to prevent entry of water. If that is not done, one might as well have no exterior cladding. Also, it may not be a structural engineer that does this\u2014her limitation to the structural discipline is incorrect; although this work is most often performed by structural engineers, it is also done by members of other disciplines.<\/span><\/p>\n<p><span style=\"font-family: georgia,palatino,serif;\">Albano mentions \u201cMechanical seals&#8230;increase cost and complications,\u201d and I would add, \u201cand they often have undesired gaps, unlike wet sealants.\u201d She goes on to describe AAMA 508-7 and AAMA 509-9. I was on the AAMA committee that developed 508, and therefore know something about this. AAMA 509 is not a pass\/fail test as is 508. Therefore, the specifier needs to specify the water and ventilation performance required. For example, I would only recommend W1 maximum and V4 minimum for performance.<\/span><\/p>\n<p><span style=\"font-family: georgia,palatino,serif;\">A few other edits for <a href=\"http:\/\/www.kenilworth.com\/publications\/cs\/de\/201509\/files\/99.html\" target=\"_blank\">page 99<\/a>:<\/span><\/p>\n<ol>\n<li><span style=\"font-family: georgia,palatino,serif;\">When the author says, \u201cThe specifier must ensure&#8230;according to the test\u2019s standards,\u201d I would add, \u201cfor both types of systems,\u201d and change \u201ctest\u2019s\u201d to \u201ctests\u2019.\u201d<\/span><\/li>\n<li><span style=\"font-family: georgia,palatino,serif;\">To \u201cThe system is a form of double-wall construction that uses an outer layer to keep out&#8230;,\u201d I would add, \u201cmost of\u201d before the words \u201cthe rain.\u201d<\/span><\/li>\n<li><span style=\"font-family: georgia,palatino,serif;\">Immediately after, Albano gives a list of functions, to which I would add, \u201cprevent penetration of water that gets past the cladding.\u201d<\/span><\/li>\n<li><span style=\"font-family: georgia,palatino,serif;\">In the next paragraph, she writes, \u201cThe structural frame of the building is kept absolutely dry, as water never reaches it or the thermal insulation.\u201d However, \u201cnever\u201d is a gross oversimplification.<\/span><\/li>\n<li><span style=\"font-family: georgia,palatino,serif;\">The author adds, \u201cEvaporation and drainage in the cavity removes water that penetrates between panel joints,\u201d to which I would suggest adding, \u201cif it hasn\u2019t gotten through the weather barrier and into the building through imperfections in the water barrier.\u201d<\/span><\/li>\n<li><span style=\"font-family: georgia,palatino,serif;\">To the statement, \u201cThere is no significant pressure differential to drive rain through joints,\u201d I would add, \u201cexcept during gust winds.\u201d<\/span><\/li>\n<\/ol>\n<p><span style=\"font-family: georgia,palatino,serif;\">On <a href=\"http:\/\/www.kenilworth.com\/publications\/cs\/de\/201509\/files\/100.html\" target=\"_blank\">page 100<\/a>, the author writes, \u201cA factory-applied sealant is applied&#8230;\u201d I would note that factory-applied sealants do not bond to the second substrate in the field, and are therefore an incomplete seal. Other jointing methods offered by fiber-cement panel manufacturers do not create a complete seal, either (except for a traditional sealed joint with a backer rod).<\/span><\/p>\n<p><span style=\"font-family: georgia,palatino,serif;\">A final point\u2014in the concluding section, as in the rest of the article, it says nothing about the critical importance of the weather water barrier, as an air and water barrier meeting Air Barrier Association of America (ABAA) standards for air barriers and performing as a water barrier. To determine the adequacy of the latter, a field mockup test is recommended, but is not mentioned in the article.<\/span><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In our September 2015 issue, we published the article, \u201cFiber Cement Panels as Rainscreens,\u201d by Carolina Albano. One reader, Richard Keleher (RJKeleher Architect), wrote to offer his thoughts about the piece and the subject matter in general. We shared with the author, who thanked him for his comments, and present it here:<\/p>\n","protected":false},"author":6,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[2],"tags":[],"class_list":["post-13840","post","type-post","status-publish","format-standard","hentry","category-matter-of-spec","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>A reader comments on fiber cement feature - The Construction Specifier<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A reader comments on fiber cement feature - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"In our September 2015 issue, we published the article, \u201cFiber Cement Panels as Rainscreens,\u201d by Carolina Albano. One reader, Richard Keleher (RJKeleher Architect), wrote to offer his thoughts about the piece and the subject matter in general. We shared with the author, who thanked him for his comments, and present it here:\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2015-12-23T17:52:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-11-24T16:40:49+00:00\" \/>\n<meta name=\"author\" content=\"Erik Missio\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Erik Missio\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-reader-comments-on-fiber-cement-feature\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-reader-comments-on-fiber-cement-feature\\\/\"},\"author\":{\"name\":\"Erik Missio\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/8fefc680f3405e56509c50d8af04d43b\"},\"headline\":\"A reader comments on fiber cement feature\",\"datePublished\":\"2015-12-23T17:52:18+00:00\",\"dateModified\":\"2016-11-24T16:40:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-reader-comments-on-fiber-cement-feature\\\/\"},\"wordCount\":670,\"commentCount\":2,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"articleSection\":[\"Matter of Spec\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/a-reader-comments-on-fiber-cement-feature\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-reader-comments-on-fiber-cement-feature\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-reader-comments-on-fiber-cement-feature\\\/\",\"name\":\"A reader comments on fiber cement feature - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"datePublished\":\"2015-12-23T17:52:18+00:00\",\"dateModified\":\"2016-11-24T16:40:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-reader-comments-on-fiber-cement-feature\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/a-reader-comments-on-fiber-cement-feature\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/a-reader-comments-on-fiber-cement-feature\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"A reader comments on fiber cement feature\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/8fefc680f3405e56509c50d8af04d43b\",\"name\":\"Erik Missio\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9bcb6d499da6ef3612a8460a592f43517f3e700351d9aae442889327fe0effa1?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9bcb6d499da6ef3612a8460a592f43517f3e700351d9aae442889327fe0effa1?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9bcb6d499da6ef3612a8460a592f43517f3e700351d9aae442889327fe0effa1?s=96&d=mm&r=g\",\"caption\":\"Erik Missio\"},\"sameAs\":[\"http:\\\/\\\/www.constructionspecifier.com\"],\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/erik-missio\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"A reader comments on fiber cement feature - The Construction Specifier","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/","og_locale":"en_US","og_type":"article","og_title":"A reader comments on fiber cement feature - The Construction Specifier","og_description":"In our September 2015 issue, we published the article, \u201cFiber Cement Panels as Rainscreens,\u201d by Carolina Albano. One reader, Richard Keleher (RJKeleher Architect), wrote to offer his thoughts about the piece and the subject matter in general. We shared with the author, who thanked him for his comments, and present it here:","og_url":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/","og_site_name":"The Construction Specifier","article_published_time":"2015-12-23T17:52:18+00:00","article_modified_time":"2016-11-24T16:40:49+00:00","author":"Erik Missio","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Erik Missio","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/"},"author":{"name":"Erik Missio","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/8fefc680f3405e56509c50d8af04d43b"},"headline":"A reader comments on fiber cement feature","datePublished":"2015-12-23T17:52:18+00:00","dateModified":"2016-11-24T16:40:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/"},"wordCount":670,"commentCount":2,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"articleSection":["Matter of Spec"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/","url":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/","name":"A reader comments on fiber cement feature - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"datePublished":"2015-12-23T17:52:18+00:00","dateModified":"2016-11-24T16:40:49+00:00","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/a-reader-comments-on-fiber-cement-feature\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"A reader comments on fiber cement feature"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/8fefc680f3405e56509c50d8af04d43b","name":"Erik Missio","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/9bcb6d499da6ef3612a8460a592f43517f3e700351d9aae442889327fe0effa1?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9bcb6d499da6ef3612a8460a592f43517f3e700351d9aae442889327fe0effa1?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9bcb6d499da6ef3612a8460a592f43517f3e700351d9aae442889327fe0effa1?s=96&d=mm&r=g","caption":"Erik Missio"},"sameAs":["http:\/\/www.constructionspecifier.com"],"url":"https:\/\/www.constructionspecifier.com\/author\/erik-missio\/"}]}},"views":4604,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/13840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=13840"}],"version-history":[{"count":2,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/13840\/revisions"}],"predecessor-version":[{"id":13845,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/13840\/revisions\/13845"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=13840"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=13840"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=13840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}