{"id":13948,"date":"2015-12-29T11:00:06","date_gmt":"2015-12-29T16:00:06","guid":{"rendered":"http:\/\/www.constructionspecifier.com\/?p=13948"},"modified":"2016-02-02T11:36:46","modified_gmt":"2016-02-02T16:36:46","slug":"specifying-seismic-ceiling-safety","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/","title":{"rendered":"Specifying seismic ceiling safety"},"content":{"rendered":"<figure id=\"attachment_13959\" aria-describedby=\"caption-attachment-13959\" style=\"width: 330px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-13959 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg\" alt=\"ROCKFON_AR_ASU-HSS_Pebble3603\" width=\"330\" height=\"220\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg 480w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603-300x200.jpg 300w\" sizes=\"auto, (max-width: 330px) 100vw, 330px\" \/><\/a><figcaption id=\"caption-attachment-13959\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: 8pt;\">Photos \u00a9 Pepple Photography. Photos courtesy Rockfon<\/span><\/figcaption><\/figure>\n<p><strong>by Mark Taylor<br \/>\n<\/strong>The International Building Code (IBC) sets minimum requirements for life safety and preservation of property. All 50 states and the U.S. Virgin Islands use the code at local or statewide levels. Following its requirements helps increase safety and may decrease possible long-term liability costs. Properly specified and installed in commercial buildings, ceiling suspension systems with acoustic panels can meet current codes and seismic performance requirements across the United States.<\/p>\n<p>According to the 2012 <em>IBC<\/em>, a Seismic Design Category (SDC) must be established for each construction project based on anticipated ground motion, the type of soil in a specific geographic area, and the occupancy category. These SDCs determine specific product performance and installation methods required by code to withstand certain seismic activity levels.<\/p>\n<p>A professional engineer or a registered architect must specify the SDC on the project drawings. Structural engineers ultimately have responsibility for building elements and systems that carry the structure\u2019s loads. However, these components only represent 25 percent of a typical commercial building\u2019s inventory. The remaining 75 percent are non-structural components\u2014such as is the case for suspended ceiling systems\u2014where responsibilities are assigned to multiple team members.<\/p>\n<p><strong>Industry standard construction<br \/>\n<\/strong>Ceilings are important non-structural components vulnerable to earthquake damage, even in well-designed buildings. Suspended, acoustic panel ceilings have been the preferred design choice in commercial buildings since the 1950s. The interconnected ceiling systems typically consist of a metal grid comprising cross-tees and main runners.<\/p>\n<p>The main runners are suspended by hanger wires from the structure above, and wall channels or angles provide a clean look around the perimeter. Lay-in and snap-up ceiling panels, such as stone wool acoustic ceiling tiles, are used to conceal the visible structure, pipes, wires, HVAC equipment, and suspension system.<\/p>\n<p>For frequently accessed plenum areas, ceiling suspension systems with snap-up torsion spring panels allow maintenance staff access without completely removing the panel. The connection\u2019s strength to the suspension system enables torsion spring panels to be effective in areas concerned with seismic activity.<\/p>\n<p>During a seismic event, damage can occur at the perimeter when the vibration period of ceiling systems significantly differs from the surrounding building structure and other nonstructural components, such as non-load-bearing partition walls. This can compromise structural integrity at the perimeter, increasing ceiling motion and also potentially leading to total failure of the ceiling system. Ceilings with heavy lighting fixtures may be susceptible to damage around the fixtures, causing light fixtures to fall into the occupied spaces. The consequences may include damaged property, blocked egress, and life-safety hazards.<\/p>\n<figure id=\"attachment_13964\" aria-describedby=\"caption-attachment-13964\" style=\"width: 340px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/Figure-1_seismic.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-13964 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/Figure-1_seismic.jpg\" alt=\"CS_January2016.indd\" width=\"340\" height=\"198\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/Figure-1_seismic.jpg 1046w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/Figure-1_seismic-300x175.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/Figure-1_seismic-1000x582.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/Figure-1_seismic-624x363.jpg 624w\" sizes=\"auto, (max-width: 340px) 100vw, 340px\" \/><\/a><figcaption id=\"caption-attachment-13964\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: 10pt;\">The Seismic Design Categories (SDCs) set out in the 2012 edition of the International Building Code (IBC).<\/span><\/figcaption><\/figure>\n<p>Intended to minimize risk and damage, installation standards for ceiling suspension systems in SDCs are specified to ensure:<\/p>\n<ul>\n<li>ceiling suspension systems are strong enough to resist lateral force imposed upon them without failing; and<\/li>\n<li>border panels are prevented from falling from the ceiling plane.<\/li>\n<\/ul>\n<p>ASTM E580\/E580M, <em>Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions<\/em>, covers acoustical ceiling suspension systems and their additional requirements for SDC C, D, E, and F as outlined in <em>IBC<\/em> 2012 (Figure 1). Local authorities having jurisdiction (AHJs) determine the application of these practices often using project specifications and detailed information from ceiling manufacturers and industry associations.<\/p>\n<p>The 2014 Ceilings &amp; Interior Systems Construction Association (CISCA) <a href=\"http:\/\/www.cisca.org\/i4a\/ams\/amsstore\/itemview.cfm?ID=274\" target=\"_blank\"><em>Seismic <\/em><em>Construction Handbook<\/em><\/a> summarizes industry standard construction per the 2012 <em>IBC<\/em> for acoustical ceiling suspension systems. The chart in \u201c<em>IBC<\/em> 2012 Industry Standard Construction\u201d references the CISCA handbook and shows the substantial differences for SDC C and SDCs D, E, and F with respect to the significance of a particular project\u2019s seismic vulnerability.<!--nextpage--><\/p>\n<p><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/seismic-Image.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-13971 size-full\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/seismic-Image.jpg\" alt=\"seismic-Image\" width=\"823\" height=\"2048\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/seismic-Image.jpg 823w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/seismic-Image-121x300.jpg 121w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/seismic-Image-402x1000.jpg 402w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/seismic-Image-624x1553.jpg 624w\" sizes=\"auto, (max-width: 823px) 100vw, 823px\" \/><\/a><\/p>\n<p><!--nextpage--><\/p>\n<figure id=\"attachment_13969\" aria-describedby=\"caption-attachment-13969\" style=\"width: 299px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3613.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-13969 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3613.jpg\" alt=\"ROCKFON_AR_ASU-HSS_Pebble3613\" width=\"299\" height=\"199\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3613.jpg 480w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3613-300x200.jpg 300w\" sizes=\"auto, (max-width: 299px) 100vw, 299px\" \/><\/a><figcaption id=\"caption-attachment-13969\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: 10pt;\">Budget constraints required value engineered options for the Humanities and Social Sciences Building\u2019s ceiling systems selections, which included stone wool acoustic ceiling panels and seismic ceiling suspension systems.<\/span><\/figcaption><\/figure>\n<p><strong>Installation and inspection<br \/>\n<\/strong>As noted in the chart, most ceiling systems are offered in \u2018intermediate-duty\u2019 and \u2018heavy-duty\u2019 performance per ASTM C635, <em>Standard <\/em><em>Specification for the Manufacture, Performance, and <\/em><em>Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings<\/em>, to satisfy the requirements of all seismic code constructions. The exposed tee construction permits direct upward access to mechanical systems and is a cost-effective solution to seismic requirements. Stab-in cross-tees cantilever during installation and will not fall out, making not only for an easier installation, but also protecting against lateral pull-out.<\/p>\n<p>Current code requirements include a 50-mm (2-in.) wide perimeter wall molding, and stabilizer bars to provide support, and prevent the ceiling grid from spreading apart along the molding. Some ceiling manufacturers offer a seismic perimeter clip as an alternate method of stabilizing tees at the perimeter. This allows installing contractors to use a 24-mm (15\u204416-in.) angle in lieu of the 50-mm (2-in.) angle and eliminates costly stabilizer bars. Supporting timesaving, error-free installation, at least one manufacturer provides the seismic perimeter clip with pre-drilled screw holes and in a bright gold to make it easily identifiable on jobsite inspections.<\/p>\n<p>While <em>IBC<\/em> establishes the requirements, it is the code official that has the power to enforce its provisions. Code officials also have the latitude to allow materials and methods of construction not addressed in the code. In this case, they can perform their own analysis of the evidence presented or they can rely on independent, qualified sources such as International Code Council-Evaluation Services (ICC-ES) to do the analysis and provide their findings. The ICC-ES resulting report is specific, technical evidence on which the code official can base approval of a particular design without delaying construction.<\/p>\n<figure id=\"attachment_13975\" aria-describedby=\"caption-attachment-13975\" style=\"width: 236px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_SS-1496SeismicPerimeterClip.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-13975 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_SS-1496SeismicPerimeterClip.jpg\" alt=\"ROCKFON_SS-1496SeismicPerimeterClip\" width=\"236\" height=\"177\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_SS-1496SeismicPerimeterClip.jpg 480w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_SS-1496SeismicPerimeterClip-300x225.jpg 300w\" sizes=\"auto, (max-width: 236px) 100vw, 236px\" \/><\/a><figcaption id=\"caption-attachment-13975\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: 10pt;\">This clip meets seismic criteria set forth by IBC to stabilize main and cross-tees at the ceiling\u2019s perimeter. It ties together perimeter components and has been tested and recognized as an alternate method of stabilizing tees at the perimeter. Its robust construction allows contractors to use a sleek 24-mm (15\u204416-in.) angle in lieu of the less-desirable 50-mm (2-in.) angle and eliminates costly stabilizer bars.<\/span><\/figcaption><\/figure>\n<p>As ceiling panel performance and non-tee bar suspension systems are not well-defined in the <em>IBC<\/em> requirements, ceiling system manufacturers and structural engineering firms have worked together to test both standard and non-standard ceiling systems for seismic performance at the Structural Engineering Earthquake Simulation Laboratory (SEESL) at the State University of New York (SUNY) at Buffalo. The results of these full-scale seismic tests offer proven safety and performance support for standard and non-standard ceilings, flexible design options, and more efficient installation designs.<\/p>\n<p>Properly specified and installed, ceiling suspension systems with acoustic panels can meet current codes and seismic performance requirements in all SDCs and all U.S. jurisdictions. When engineered to reduce installation time, ceiling suspension systems not only support life safety and the property preservation during an earthquake, but they also can save associated material and labor costs. Combined with the inherent properties of stone wool acoustic ceiling panels, these systems also protect people from noise and the spread of fire, while making a constructive contribution toward a sustainable future. For more information on stone wool ceiling assemblies, click <a href=\"http:\/\/www.constructionspecifier.com\/designing-stone-wool-ceiling-assemblies\" target=\"_blank\">here.<\/a><\/p>\n<p><em>Mark Taylor is the marketing manager for Rockfon\u2019s ceiling systems for North America. He began his career in the commercial building industry as a carpenter; in addition to field experience, he earned a bachelor\u2019s degree in industrial technology from Eastern Illinois University. Continuing to grow and share his industry knowledge, Taylor is a member of the Ceilings &amp; Interior Systems Construction Association (CISCA) and recently published Rockfon\u2019s new brochure titled, \u201cSeismic Relief.\u201d He can be reached at <a href=\"mailto:mtaylor@rockfon.com\" target=\"_blank\">mtaylor@rockfon.com<\/a>.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The International Building Code (IBC) sets minimum requirements for life safety and preservation of property. All 50 states and the U.S. Virgin Islands use the code at local or statewide levels. Following its requirements helps increase safety and may decrease possible long-term liability costs.<\/p>\n","protected":false},"author":5,"featured_media":13959,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,179,449,189,283,193,316,511,463],"tags":[827,2317,2313,2318,1096,1259,2314,2315,2316,700],"class_list":["post-13948","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-masterformat","category-uniformat","category-09-00-00-finishes","category-09-50-00-ceilings","category-13-00-00-special-construction","category-13-40-00-integrated-construction","category-c2050ceiling-finishes","category-c20interior-finishes","tag-09-51-00acoustical-ceilings","tag-13-48-00sound","tag-acoustic","tag-and-seismic-control","tag-ceiling","tag-division-09","tag-earthquake","tag-seismic","tag-suspension","tag-vibration","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Specifying seismic ceiling safety - The Construction Specifier<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/\" \/>\n<link rel=\"next\" href=\"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Specifying seismic ceiling safety - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"The International Building Code (IBC) sets minimum requirements for life safety and preservation of property. All 50 states and the U.S. Virgin Islands use the code at local or statewide levels. Following its requirements helps increase safety and may decrease possible long-term liability costs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2015-12-29T16:00:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-02-02T16:36:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"320\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Katie Daniel\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Katie Daniel\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/\"},\"author\":{\"name\":\"Katie Daniel\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/34e59e3f0bf081d4b975ae9b2c1764f3\"},\"headline\":\"Specifying seismic ceiling safety\",\"datePublished\":\"2015-12-29T16:00:06+00:00\",\"dateModified\":\"2016-02-02T16:36:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/\"},\"wordCount\":1288,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg\",\"keywords\":[\"09 51 00?Acoustical Ceilings\",\"13 48 00\u2212Sound\",\"Acoustic\",\"and Seismic Control\",\"Ceiling\",\"Division 09\",\"Earthquake\",\"Seismic\",\"Suspension\",\"Vibration\"],\"articleSection\":[\"Features\",\"MasterFormat\",\"UniFormat\",\"09 00 00 Finishes\",\"09 50 00 Ceilings\",\"13 00 00 Special Construction\",\"13 40 00 Integrated Construction\",\"C2050\u2212Ceiling Finishes\",\"C20\u2212Interior Finishes\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/\",\"name\":\"Specifying seismic ceiling safety - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg\",\"datePublished\":\"2015-12-29T16:00:06+00:00\",\"dateModified\":\"2016-02-02T16:36:46+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/specifying-seismic-ceiling-safety\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg\",\"width\":480,\"height\":320},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/34e59e3f0bf081d4b975ae9b2c1764f3\",\"name\":\"Katie Daniel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g\",\"caption\":\"Katie Daniel\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/katie-daniel\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Specifying seismic ceiling safety - The Construction Specifier","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/","next":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/2\/","og_locale":"en_US","og_type":"article","og_title":"Specifying seismic ceiling safety - The Construction Specifier","og_description":"The International Building Code (IBC) sets minimum requirements for life safety and preservation of property. All 50 states and the U.S. Virgin Islands use the code at local or statewide levels. Following its requirements helps increase safety and may decrease possible long-term liability costs.","og_url":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/","og_site_name":"The Construction Specifier","article_published_time":"2015-12-29T16:00:06+00:00","article_modified_time":"2016-02-02T16:36:46+00:00","og_image":[{"width":480,"height":320,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg","type":"image\/jpeg"}],"author":"Katie Daniel","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Katie Daniel","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/"},"author":{"name":"Katie Daniel","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/34e59e3f0bf081d4b975ae9b2c1764f3"},"headline":"Specifying seismic ceiling safety","datePublished":"2015-12-29T16:00:06+00:00","dateModified":"2016-02-02T16:36:46+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/"},"wordCount":1288,"commentCount":1,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg","keywords":["09 51 00?Acoustical Ceilings","13 48 00\u2212Sound","Acoustic","and Seismic Control","Ceiling","Division 09","Earthquake","Seismic","Suspension","Vibration"],"articleSection":["Features","MasterFormat","UniFormat","09 00 00 Finishes","09 50 00 Ceilings","13 00 00 Special Construction","13 40 00 Integrated Construction","C2050\u2212Ceiling Finishes","C20\u2212Interior Finishes"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/","url":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/","name":"Specifying seismic ceiling safety - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg","datePublished":"2015-12-29T16:00:06+00:00","dateModified":"2016-02-02T16:36:46+00:00","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/specifying-seismic-ceiling-safety\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/12\/ROCKFON_AR_ASU-HSS_Pebble3603.jpg","width":480,"height":320},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/34e59e3f0bf081d4b975ae9b2c1764f3","name":"Katie Daniel","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g","caption":"Katie Daniel"},"url":"https:\/\/www.constructionspecifier.com\/author\/katie-daniel\/"}]}},"views":22434,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/13948","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=13948"}],"version-history":[{"count":12,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/13948\/revisions"}],"predecessor-version":[{"id":14901,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/13948\/revisions\/14901"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/13959"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=13948"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=13948"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=13948"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}