{"id":14208,"date":"2013-01-04T12:17:09","date_gmt":"2013-01-04T17:17:09","guid":{"rendered":"http:\/\/www.constructionspecifier.com\/?p=14208"},"modified":"2017-01-20T14:30:31","modified_gmt":"2017-01-20T19:30:31","slug":"ensuring-moisture-protection-for-manufactured-stone","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/","title":{"rendered":"Ensuring moisture protection for manufactured stone"},"content":{"rendered":"<figure id=\"attachment_14239\" aria-describedby=\"caption-attachment-14239\" style=\"width: 249px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-14239\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot.jpg\" alt=\"All images courtesy Sto Corp. \" width=\"249\" height=\"347\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot.jpg 573w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot-215x300.jpg 215w\" sizes=\"auto, (max-width: 249px) 100vw, 249px\" \/><\/a><figcaption id=\"caption-attachment-14239\" class=\"wp-caption-text\"><em><span style=\"font-size: 8pt;\">All images courtesy Sto Corp.<\/span><\/em><\/figcaption><\/figure>\n<p><strong>by Jeff Diqui, Arch. Eng., CSI<br \/>\n<\/strong>Failures of claddings like adhered masonry veneer\u2013also known as manufactured stone\u2013often stem from poor flashings, misapplied air and water-resistive barriers (WRBs), and limited drainage. Resulting problems related to moisture intrusion into the wall assembly\u2019s dry zone are moist wall interiors, wet insulation, and rot in sheathing and framing.<\/p>\n<p>Experience has shown detailing flaws in cast-stone veneer causes leaks which can lead to severe damage inside the wall. Rain and wind are often the culprits. A related effect in adhered masonry veneer cladding is inward vapor drive, which can occur in warm weather. It forces moisture stored in the masonry through vapor-permeable housewraps and building papers and into the sheathing and stud bay. This can lead to condensation and water accumulation within walls, as well as wood decay and condensation on interior surfaces.\u00a0(For more information, see \u201cAdhered Veneers and Inward Vapor Drives,\u201d in the summer 2009 edition of <i>Journal of Building Enclosure Design<\/i> by John Straube, P.Eng., PhD, et al.)<\/p>\n<p>Some have assumed WRBs between claddings and sheathing layers prevent moisture damage. Research and field experience demonstrate the WRB alone may not always suffice.\u00a0(See \u201cImproving Drainage and Drying Features in Certain Conditions: Rain Screen Designs for Absorptive Claddings,\u201d in the December 2008 report by National Association of Home Builders [NAHB].)\u00a0Common practices, such\u00a0as using double layers of housewraps or asphalt-impregnated papers behind the absorptive claddings, are shown to be ineffective under some climate and weather conditions, particularly if poorly constructed details allow excess water into walls.<\/p>\n<p>Moisture infiltration and damage should be avoided; design detailing can prevent water entry into walls. Additional protection behind absorptive claddings is afforded with three integrated components: a drainage plane, a properly located and continuous air barrier and WRB, and an air gap or space created by a drainage medium, such as filament nylon mesh. Some of these solutions are cavity-wall systems, engineered by a single manufacturer, while others are built-up assemblies consisting of several components.<\/p>\n<p>Applied with fundamentally sound design details, these three elements provide an enhanced drainage-and-drying assembly that improves enclosure performance. Recent code changes\u2014including the 2012 <i>International <\/i><i>Building Code<\/i> (<i>IBC<\/i>) and <i>International Energy Conservation <\/i><i>Code<\/i> (<i>IECC<\/i>), which include requirements for WRBs, air barriers, continuous insulation (ci), and drainage\u2014reflect the effectiveness of this approach in mitigating moisture damage.<\/p>\n<figure id=\"attachment_14242\" aria-describedby=\"caption-attachment-14242\" style=\"width: 180px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/GRAPHIC-for-Dec2012-1-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14242 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/GRAPHIC-for-Dec2012-1-2-523x1000.jpg\" alt=\"\" width=\"180\" height=\"344\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/GRAPHIC-for-Dec2012-1-2-523x1000.jpg 523w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/GRAPHIC-for-Dec2012-1-2-157x300.jpg 157w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/GRAPHIC-for-Dec2012-1-2-624x1193.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/GRAPHIC-for-Dec2012-1-2.jpg 917w\" sizes=\"auto, (max-width: 180px) 100vw, 180px\" \/><\/a><figcaption id=\"caption-attachment-14242\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">Inward vapor drive forces moisture stored in the masonry through vapor-permeable housewraps and building papers, and then into the sheathing and stud bay.<\/span><\/figcaption><\/figure>\n<p><b>What is not working?<\/b><br \/>\nConventional walls using absorptive claddings for residential and light commercial buildings have typically employed a concealed barrier approach to water management. (See \u201cImproving Drainage and Drying Features in Certain Conditions: Rain Screen Designs for Absorptive Claddings,\u201d in the December 2008 report by National Association of Home Builders [NAHB].)\u00a0Any water penetrating the adhered masonry veneer cladding encounters the WRB\u2014usually felt, building paper, or housewrap\u2014intended to stop the migration of bulk water. This common assembly may not always be sufficient for adhered masonry and thin brick veneer.<\/p>\n<p>These claddings tend to absorb water through their molded facing units, mortars, and scratch coats. Moreover, according to experts such as John Straube, P.Eng., PhD, they have low outward drying potential as compared to other cladding types, and tend to dry slower. The absorptive elements are typically applied as the outermost wall materials, so they are likely to encounter wind-driven rain, airborne moisture, and even lawn sprinkler spray.<\/p>\n<p>Behind the fa\u00e7ade, the cementitious facing materials are typically in direct contact with the WRB that is intended to stop bulk water intrusion, moving any water to flashings or weep screeds. Water sometimes remains in places where the cladding is in contact with the barrier (see \u201cImproving Drainage and Drying Features in Certain Conditions: Rain Screen Designs for Absorptive Claddings,\u201d in the December 2008 report by National Association of Home Builders [NAHB]); under some conditions, those locations may remain wet for long periods.\u00a0(For more information, see \u201cAdhered Veneers and Inward Vapor Drives,\u201d in the summer 2009 edition of <i>Journal of Building Enclosure Design<\/i> by John Straube, P.Eng., PhD, et al.)<\/p>\n<p>Various methods have been used to improve this simple assembly type. Some housewraps and WRBs have been reformulated to provide enhanced protection. Furring strips can be employed between the two WRB layers as a rainscreen. Other drainage spacers\u2014including dimple sheets and drainage mats\u2014have been shown to enhance drainage and drying within the wall.\u00a0(See \u201cWater-managed Wall Systems\u201d in a 2007 issue of <i>The Journal of Light Construction<\/i> by Joseph Lstiburek, M.Eng., PhD, P.Eng.)<\/p>\n<p>Yet, bulk water intrusion is not the only enemy; another challenge is inward water vapor drive. Since many WRBs are highly vapor-permeable, the moisture stored within the masonry veneer or mortars can be driven by the sun, directly heated through WRBs, and into the sheathing and stud bays behind (even in cold climates).<\/p>\n<p>Bulk water intrusion and vapor drive have led to damage and rot in sheathing and structural members, both in wood- and steel-framed structures. (For more, see the report, \u201cDevelopment of a Rainscreen System for Adhered Manufactured Stone,\u201d by Robert Rymell, P.Eng., C.Eng., from the 2007 Canadian Building Science and Technology Conference, hosted by the Alberta Building Envelope Council [ABEC] South.) Some WRBs deteriorate over time or moisture can get in through errant fastener penetrations that miss studs, or both.<!--nextpage--><\/p>\n<figure id=\"attachment_14250\" aria-describedby=\"caption-attachment-14250\" style=\"width: 240px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/DrainScreen-roll.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-14250\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/DrainScreen-roll-279x300.jpg\" alt=\"A filament nylon drainage mat is an effective means to provide an air gap and drainage cavity. \" width=\"240\" height=\"258\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/DrainScreen-roll-279x300.jpg 279w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/DrainScreen-roll-624x670.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/DrainScreen-roll.jpg 745w\" sizes=\"auto, (max-width: 240px) 100vw, 240px\" \/><\/a><figcaption id=\"caption-attachment-14250\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">A filament nylon drainage mat is an effective means<\/span>\u00a0<span style=\"font-size: 10pt;\">to provide an air gap and drainage cavity.<\/span><\/figcaption><\/figure>\n<p>Facing these challenges, construction experts and specifiers have recommended additional or alternative means to promote drainage and drying within the wall. Some of these practices have included ventilated air gaps, which can <a href=\"http:\/\/www.ornl.gov\/sci\/roofs+walls\/staff\/papers\/210.pdf\" target=\"_blank\">promote drying<\/a>, as well as impermeable membranes paired with air gaps, or rainscreen-type construction.<\/p>\n<p>The findings are valuable not only for reducing premature wear, but also for increasing the durability of structures desiring a masonry look. The basic underpinnings of the new approach to adhered masonry can be summarized as two lists: minimal measures required by code, and supplemental measures for enhanced protection.<\/p>\n<p><b>Minimal measures<\/b><br \/>\nMinimal measures include building papers, felts, and housewraps, along with WRBs.<\/p>\n<p><i>Building papers, felts, and housewraps<\/i><br \/>\nA single layer of these water-permeable materials may not always be enough for adhered masonry veneer claddings. An application of two layers of building paper is better, but serves only as the minimum backup for walls faced with thin brick or manufactured masonry veneer.\u00a0(For more, see the article, \u201cManufactured Stone Nightmares,\u201d by Dennis McCoy in the December 2004 issue of the <i>Journal of Light Construction<\/i>\u00a0[<i>JCL<\/i>.])<\/p>\n<p><i>WRBs<\/i><br \/>\nAccording to various studies\u2014including the National Association of Home Builders\u2019 (NAHB\u2019s) 2008 report, \u201cImproving Drainage and Drying Features in Certain Conditions: Rainscreen Designs for Absorptive Claddings\u201d\u2014using WRBs alone is not sufficient to prevent water infiltration and moisture-related damage behind adhered masonry veneers. One key to successful, durable construction is the location of the barrier (drainage plane), as well as its continuous nature across the entire enclosure and its integration with flashings, weep screeds, and other joint\/penetration details.<\/p>\n<p><b>Enhanced measures<\/b><br \/>\nThe enhanced measures include ventilated airspace, capillary absorption, and drainage media.<\/p>\n<p><i>Ventilated air space<\/i><br \/>\nThe use of wall ventilation by means of an air space has been shown to improve drying within the wall, and reduce moisture-related damage. Straube\u2019s study concluded the small resulting space by an air-gap membrane provides sufficient ventilation, allowing a faster rate of outward drying than traditional adhered veneers.<\/p>\n<p>Walls using air-gap membranes or other materials to maintain the gap\u2014such as furring strips, drainage mats, and profiled boards\u2014tend to have lower sheathing moisture content. Walls with the proper air space generally do not experience moisture-related durability issues caused by relative humidity (RH).<\/p>\n<p>According to the NAHB report, using a drainage spacer to provide a capillary break for ventilation and drying can improve drainage and drying performance.<\/p>\n<p>To achieve the capillary break and maintain effective drainage, the researchers concluded the minimum depth of the cavity should be 3.2 mm (1\/8 in.), maintained throughout the enclosure. A maximum depth of 19 mm (3\/4 in.) has been recommended by some specifiers and manufacturers. The NAHB report described a drainage space between 5.9 to 10.3 mm (15\/64 to 13\/32 in.) in depth, maintained by a two-ply material with a filter fabric separator preventing materials from blocking drainage space. This report recognized mortar or debris may enter the air gap.<\/p>\n<p>Offering a prescriptive approach, the 2005 <i>National <\/i><i>Building Code of Canada<\/i> (<i>NBC<\/i>) has required a \u201cdrained and vented air space\u201d of at least 10 mm (2\/5 in.) with a cross-sectional area that is at least 80 percent open for coastal climates.<\/p>\n<figure id=\"attachment_14262\" aria-describedby=\"caption-attachment-14262\" style=\"width: 300px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-penetration.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-14262\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-penetration-300x200.jpg\" alt=\"Having continuous air- and moisture-barrier protection around penetrations and window openings is critical to the long-term durability of the wall.\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-penetration-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-penetration-624x416.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-penetration.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-14262\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">Having continuous air- and moisture-barrier protection around penetrations\u00a0and window openings is critical to the long-term durability of the wall.<\/span><\/figcaption><\/figure>\n<p><i>Capillary absorption<\/i><br \/>\nMeasures to address capillary water movement\u2014through both mortar and masonry units\u2014are also vital to successful wall construction. According to construction consultant Steve Easley, in adhered manufactured stone masonry veneer (AMSMV), a main instrument for moisture movement is capillary action. Considered a reservoir cladding system\u2014as it can store water\u2014Easley says, AMSMV is similar to stucco in the way it behaves with water. The effect can also be described in terms of hydrostatic pressure.<\/p>\n<p>The two-layer WRB system provides a drainage plane to protect against the capillary draw, explains Easley, but an even better option is a rainscreen system with a small airspace between the WRB and stone veneer\u2014creating a drainage space which better prevents water intrusion. A ventilated air space allows bulk water to drain out, but also serves as the needed capillary break, meaning water penetrating behind the cladding is intercepted. (Steve Easley\u2019s 2010 article, \u201cWeatherproofing Synthetic Stone Veneers,\u201d can be read online at <a href=\"http:\/\/www.greenbuildermag.com\" target=\"_blank\">www.greenbuildermag.com<\/a>.)<span style=\"font-size: 11px;\">\u00a0<\/span><\/p>\n<p><i>Drainage media\u00a0<\/i><br \/>\nFor proper drainage behind adhered masonry veneers, designers and contractors have found it critical to keep the scratch coat and mortar out of the air gap, necessitating vigilance among installers. In many cases, designers and\/or contractors have recommended using a drainage mat with a filter-fabric backing to prevent clogging the air space.<\/p>\n<p>For example, the Residential Masonry Contractors Association (RMAC) made recommendations for manufactured stone veneer over wood-frame construction, which included a drainage mat with filter fabric backing. A similar recommendation was made by the Builders Association of Minnesota (BAM), with details including a drainage mat material (or furring strips) that separate the WRB applied to the sheathing away from a layer of building paper. The measure is intended to keep scratch coat or mortar out of the drainage space.<!--nextpage--><\/p>\n<figure id=\"attachment_14265\" aria-describedby=\"caption-attachment-14265\" style=\"width: 342px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-window-opening.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-14265\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-window-opening-300x200.jpg\" alt=\"Fluid applied air- and moisture-barriers simplify installation on the openings with complex geometries.\" width=\"342\" height=\"228\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-window-opening-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-window-opening-624x416.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/rapidseal-window-opening.jpg 800w\" sizes=\"auto, (max-width: 342px) 100vw, 342px\" \/><\/a><figcaption id=\"caption-attachment-14265\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">Fluid applied air- and moisture-barriers simplify installation on the openings with complex geometries.<\/span><\/figcaption><\/figure>\n<p>According to International Code Council Evaluation Service (ICC-ES) reports, drainage mats are among the materials providing superior drainage efficiency in typical wall assemblies. (One example is International Code Council Evaluation Service [ICC-ES] Acceptance Criteria [AC] 356, <i>Moisture Drainage System Used with Exterior Cement Plaster or Adhered Masonry Veneer Walls<\/i>.) Manufactured as roll or sheet material for application over the drainage plane and behind manufactured stone and thin brick-veneer wall assemblies, the mats include rigid polymer sheets and tangled-filament polymer materials.<\/p>\n<p>Both types allow water vapor to move freely through the drainage mat layer, which accelerates drying. They also provide for a consistent air break to separate inward vapor drive from the sheathing and structure. Finally, the drainage mats provide ventilation for drying while also helping to prevent clogging of the drainage\/drying area from scratch coats and mortar.<\/p>\n<p><b>A systems approach<\/b><br \/>\nA review of industry literature, lab testing, field experience, and expert comment confirms effective designs of adhered masonry veneers should include an air gap and drainage cavity behind the claddings to improve durability and reduce moisture-related issues\u2014always in tandem with design details that keep water out of the wall in the first place. A well-defined air space and an effective means of drainage\u2014as well as a compatible and effective air barrier and WRB\u2014create a more comprehensive system for adhered masonry veneer construction. The ideal solution should include compatible materials, straightforward application techniques, and a track record of use with thin brick, adhered masonry veneer, and other similar absorptive claddings.<\/p>\n<p>Recently, several manufacturers have developed components or assemblies to specifically incorporate an air barrier, WRB, and drainage medium in a design preventing water accumulation and capillary action for use behind absorptive claddings. Some also allow for the inclusion of ci, as desired by the project team or required by code. Certain cavity-wall systems provide for a waterproof air barrier, drainage, and ci in single, multi-component systems that are assembly tested to meet typical energy and fire codes.<\/p>\n<p>Installed over wood frame, concrete masonry unit (CMU), or light-gauge steel, the cavity-wall system has a waterproof air-barrier membrane fluid-applied over the backup wall assembly to create a continuous air barrier and WRB plane integrated with transition membranes at all penetrations and interfaces. This is followed by\u00a0a continuous layer of extruded polystyrene (XPS) insulation that is covered with a tangled-filament drainage mat; masonry veneer cladding is adhered to complete the enclosure.<\/p>\n<p>The tangled-filament drainage mat facilitates moisture escape between the protected substrate and the cladding. Should water reach the area between the substrate and cladding, it can drain from the wall assembly via the drainage mat, which also helps speed the drying of moisture-laden air (water vapor) that can accumulate. In this way, cavity-wall systems provide the drainage plane, drying space, and continuous barrier to water migration as needed to protect the building sheathing and structure.<\/p>\n<p>The cavity wall offers other benefits. For example, some systems carry code approvals or have been tested according to the National Fire Protection Association (NFPA) 285, <i>Standard <\/i><i>Fire Test Method for Evaluation of Fire Propagation<\/i><i> <\/i><i>Characteristics of Exterior Non-load-bearing Wall Assemblies Containing Combustible Components<\/i>. In some situations, the cavity-wall systems also help ensure consistent application and detailing across one or more claddings, to help ensure the desired performance and mitigate risks with the integration detail that can be associated with the sequencing and coordination with multiple trades, integration detailing, and compatibility with multiple components.<\/p>\n<p><b>Design recommendations<\/b><br \/>\nOne of the most important considerations when designing to prevent moisture-related issues in wall construction is to prevent water intrusion through the use of fundamentally sound design details\u2014such as rough opening protection and sill flashing beneath windows and doors. When installing sill flashing under a window, it is considered a fundamental principle of source drainage to direct water to the exterior in the event of a window leak.<\/p>\n<p>Other examples of the source drainage principle include diverter flashing at roof\/wall intersections, saddle flashing at low-to-high walls, flashing at floor lines, and deck flashing. All these strategies prevent moisture-related issues at these locations by re-directing water to the exterior in the event of its entry into the enclosure at some component or assembly.<\/p>\n<p>Whether part of these systems or a built-up solution, the use of a minimum air space or drainage medium that creates an air space have been shown to improve the performance of absorptive claddings in resisting bulk water intrusion and inward vapor drive. Based on field experience and controlled testing, a number of conclusions can be drawn about the design of enclosures with adhered masonry veneer.<\/p>\n<p>First, research shows one or two layers of asphalt-impregnated building paper, felt, or housewrap are not always effective on their own to mitigate the moisture issues in adhered masonry veneer. Though the water-resistant papers may provide an effective drainage layer, this can be compromised by contact with the manufactured stone cladding.<\/p>\n<p>Second, the key to enhanced moisture protection of these walls is to ensure the use of a consistent air gap of at least 32 mm (1\/8 in.) in depth. Joseph Lstiburek, M.Eng., PhD, suggests the main function of the air gap is to prevent hydrostatic pressure buildup across the water-control layer by draining the water that penetrates.<\/p>\n<p>Third, a continuous air barrier is needed to prevent condensation caused by air leakage.<!--nextpage--><\/p>\n<figure id=\"attachment_14269\" aria-describedby=\"caption-attachment-14269\" style=\"width: 234px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/StoEnergy-Guard_DS_CI-Thick-Stone-Veneer.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-14269\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/StoEnergy-Guard_DS_CI-Thick-Stone-Veneer-234x300.jpg\" alt=\"Single-source advanced cavity-wall systems integrate water-resistive barriers (WRB), air barriers, drainage mats, and continuous insulation (ci) into a compatible, continuous wall system. \" width=\"234\" height=\"300\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/StoEnergy-Guard_DS_CI-Thick-Stone-Veneer-234x300.jpg 234w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/StoEnergy-Guard_DS_CI-Thick-Stone-Veneer.jpg 624w\" sizes=\"auto, (max-width: 234px) 100vw, 234px\" \/><\/a><figcaption id=\"caption-attachment-14269\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">Single-source advanced cavity-wall systems integrate water-resistive barriers (WRB), air barriers, drainage mats, and continuous insulation (ci) into a compatible, continuous wall system.<\/span><\/figcaption><\/figure>\n<p>Additionally, a rain-managed wall should consist of four elements, which Lstiburek outlined as:<\/p>\n<ul>\n<li>continuous drainage plane that is water-repellent, properly connected to flashings, window and<\/li>\n<li>door penetrations, roof-wall intersections, and service penetrations;<\/li>\n<li>drainage space between the cladding and the drainage plane;<\/li>\n<li>flashings at every opening, penetration, or intersection; and<\/li>\n<li>weep holes (<i>i.e.<\/i> openings to allow water to escape to the outside). (See \u201cWater-managed Wall Systems\u201d in a 2007 issue of <i>The Journal of Light Construction<\/i> by Joseph Lstiburek, M.Eng., PhD, P.Eng.)<\/li>\n<\/ul>\n<p>Finally, the drainage space between the cladding and the drainage plane can be successfully maintained with a material layer such as a filament nylon mesh mat or, as an alternative, a rigid plastic profiled sheet, also called a dimple sheet. The filament nylon mesh material has been tested extensively, recently by the Masonry Veneer Manufacturers Association (MVMA) in a test assembly with two layers of WRB separated by\u00a0a \u201cpolymer-entangled mesh\u201d drainage mat, as well as a metal lath and scratch coat.<\/p>\n<p>In the laboratory study, water penetration by wind-driven rain was evaluated based on ASTM E331, <i>Standard <\/i><i>Test Method for Water Penetration of <\/i><i>Exterior Windows, Skylights, Doors, and <\/i><i>Curtain Walls by Uniform Static Air Pressure Difference<\/i>. No water was observed on the interior of any of the test wall assembly during a two-hour test using the mesh drainage mat. Other types of drainage materials were also successfully tested, including formed XPS insulation, polymer mats, and wood furring. (See Masonry Veneer Manufacturers Association\u2019s [MVMA\u2019s] Technical Bulletin, \u201cWater Penetration Testing of an Adhered Masonry Veneer Wall Assembly.\u201d)<\/p>\n<p>Successful wall assemblies include\u00a0a continuous air and water barrier integral with flashings, air space, or\u00a0an air space created by such drainage media as a filament nylon mesh. These designs limit moisture-related issues and improve the performance of commonly used absorptive claddings, including adhered masonry veneer products.<\/p>\n<p><b>Conclusion<\/b><br \/>\nThe challenges of adhered masonry veneers and other absorptive claddings used in residential and light commercial construction have been widely published. The primary negative effects\u2014caused by humidity, rain, and wind\u2014include poor drainage, inward vapor drive, and capillary absorption. The moisture problems have led to enclosure failures in some cases.<\/p>\n<p>A critical review of industry literature, lab testing, field experience, and expert comment show the most effective design of adhered masonry veneers should include an air gap and drainage cavity behind the claddings to improve durability and reduce moisture issues. A fabric-faced, tangled-filament nylon drainage mat is shown to effectively promote drainage and drying in above-grade vertical wall assemblies beneath absorptive-type claddings, including adhered masonry and thin brick veneer. The filament drainage mats provide for both an air space and protected drainage plane and are also effective when used as part of a full cavity-wall system.<\/p>\n<p>In addition to the issues caused by moisture damage in residential and light commercial construction, recent code changes have propagated the use of enhanced drainage and drying assemblies for adhered masonry veneer. These code changes are valuable\u2014as are improvements to recommended practice\u2014as they help reduce enclosure failures caused by moisture damage, which are costly and avoidable. By following the code changes in the 2012 <i>IBC<\/i> and <i>IECC <\/i>for WRBs, air barriers, ci, and drainage, it will help to ensure adhered masonry systems provide long and valuable lifecycles.<\/p>\n<p><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/ChallengesOfAdheredMasonryVeneer.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14270\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/ChallengesOfAdheredMasonryVeneer.jpg\" alt=\"ChallengesOfAdheredMasonryVeneer\" width=\"1296\" height=\"429\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/ChallengesOfAdheredMasonryVeneer.jpg 1296w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/ChallengesOfAdheredMasonryVeneer-300x99.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/ChallengesOfAdheredMasonryVeneer-1000x331.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/ChallengesOfAdheredMasonryVeneer-624x207.jpg 624w\" sizes=\"auto, (max-width: 1296px) 100vw, 1296px\" \/><\/a><\/p>\n<p><em>Jeff Diqui, Arch. Eng., CSI, is a building enclosure specialist with Sto Corp. He has more than 20 years of experience with forensic investigations related to moisture intrusion and structural problems, structural design, building condition assessments, development of repair\/rehabilitation designs, and construction observations. Diqui is a consultative resource for architects, engineers, specifiers, building envelope consultants, contractors, and code officials related to heat, air, and moisture controls. He is a member of the Building Enclosure Council (BEC), Construction Specifications Institute (CSI), RCI\u2013The Institute of Roofing, Waterproofing, and Building Envelope Professionals, and the U.S. Green Building Council (USGBC). He can be contacted via e-mail at <a href=\"mailto:jdiqui@stocorp.com\" target=\"_blank\">jdiqui@stocorp.com<\/a>.\u00a0<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Failures of claddings like adhered masonry veneer\u2013also known as manufactured stone\u2013often stem from poor flashings, misapplied air and water-resistive barriers (WRBs), and limited drainage. Resulting problems related to moisture intrusion into the wall assembly\u2019s dry zone are moist wall interiors, wet insulation, and rot in sheathing and framing.<\/p>\n","protected":false},"author":10,"featured_media":14239,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,6,179,449,184,249,489,460],"tags":[2379,1237,2378,156,1318,2380,547],"class_list":["post-14208","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-general","category-masterformat","category-uniformat","category-04-00-00-masonry","category-04-70-00-manufactured-masonry","category-b2010exterior-walls","category-b20exterior-vertical-enclosures","tag-adhered-masonry-veneer","tag-division-04","tag-jeff-diqui","tag-masonry-veneer","tag-rainscreen","tag-vapor-drive","tag-water-resistive-barrier","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Ensuring moisture protection for manufactured stone - The Construction Specifier<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/\" \/>\n<link rel=\"next\" href=\"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ensuring moisture protection for manufactured stone - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Failures of claddings like adhered masonry veneer\u2013also known as manufactured stone\u2013often stem from poor flashings, misapplied air and water-resistive barriers (WRBs), and limited drainage. Resulting problems related to moisture intrusion into the wall assembly\u2019s dry zone are moist wall interiors, wet insulation, and rot in sheathing and framing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2013-01-04T17:17:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-01-20T19:30:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"573\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Catherine Howlett\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Catherine Howlett\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"17 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/\"},\"author\":{\"name\":\"Catherine Howlett\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/26c86b4baf08f39a8684e1d14a8bc049\"},\"headline\":\"Ensuring moisture protection for manufactured stone\",\"datePublished\":\"2013-01-04T17:17:09+00:00\",\"dateModified\":\"2017-01-20T19:30:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/\"},\"wordCount\":3359,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2013\\\/01\\\/openershot.jpg\",\"keywords\":[\"Adhered masonry veneer\",\"Division 04\",\"Jeff Diqui\",\"masonry veneer\",\"Rainscreen\",\"Vapor drive\",\"Water-resistive barrier\"],\"articleSection\":[\"Features\",\"General\",\"MasterFormat\",\"UniFormat\",\"04 00 00 Masonry\",\"04 70 00 Manufactured Masonry\",\"B2010\u2212Exterior Walls\",\"B20\u2212Exterior Vertical Enclosures\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/\",\"name\":\"Ensuring moisture protection for manufactured stone - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2013\\\/01\\\/openershot.jpg\",\"datePublished\":\"2013-01-04T17:17:09+00:00\",\"dateModified\":\"2017-01-20T19:30:31+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/ensuring-moisture-protection-for-manufactured-stone\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2013\\\/01\\\/openershot.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2013\\\/01\\\/openershot.jpg\",\"width\":573,\"height\":800,\"caption\":\"All images courtesy Sto Corp.\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/26c86b4baf08f39a8684e1d14a8bc049\",\"name\":\"Catherine Howlett\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g\",\"caption\":\"Catherine Howlett\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/catherine-howlett\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ensuring moisture protection for manufactured stone - The Construction Specifier","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/","next":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/2\/","og_locale":"en_US","og_type":"article","og_title":"Ensuring moisture protection for manufactured stone - The Construction Specifier","og_description":"Failures of claddings like adhered masonry veneer\u2013also known as manufactured stone\u2013often stem from poor flashings, misapplied air and water-resistive barriers (WRBs), and limited drainage. Resulting problems related to moisture intrusion into the wall assembly\u2019s dry zone are moist wall interiors, wet insulation, and rot in sheathing and framing.","og_url":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/","og_site_name":"The Construction Specifier","article_published_time":"2013-01-04T17:17:09+00:00","article_modified_time":"2017-01-20T19:30:31+00:00","og_image":[{"width":573,"height":800,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot.jpg","type":"image\/jpeg"}],"author":"Catherine Howlett","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Catherine Howlett","Est. reading time":"17 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/"},"author":{"name":"Catherine Howlett","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/26c86b4baf08f39a8684e1d14a8bc049"},"headline":"Ensuring moisture protection for manufactured stone","datePublished":"2013-01-04T17:17:09+00:00","dateModified":"2017-01-20T19:30:31+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/"},"wordCount":3359,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot.jpg","keywords":["Adhered masonry veneer","Division 04","Jeff Diqui","masonry veneer","Rainscreen","Vapor drive","Water-resistive barrier"],"articleSection":["Features","General","MasterFormat","UniFormat","04 00 00 Masonry","04 70 00 Manufactured Masonry","B2010\u2212Exterior Walls","B20\u2212Exterior Vertical Enclosures"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/","url":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/","name":"Ensuring moisture protection for manufactured stone - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot.jpg","datePublished":"2013-01-04T17:17:09+00:00","dateModified":"2017-01-20T19:30:31+00:00","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/ensuring-moisture-protection-for-manufactured-stone\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/01\/openershot.jpg","width":573,"height":800,"caption":"All images courtesy Sto Corp."},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/26c86b4baf08f39a8684e1d14a8bc049","name":"Catherine Howlett","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g","caption":"Catherine Howlett"},"url":"https:\/\/www.constructionspecifier.com\/author\/catherine-howlett\/"}]}},"views":22328,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/14208","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=14208"}],"version-history":[{"count":38,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/14208\/revisions"}],"predecessor-version":[{"id":25749,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/14208\/revisions\/25749"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/14239"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=14208"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=14208"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=14208"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}