{"id":15131,"date":"2012-12-01T17:30:03","date_gmt":"2012-12-01T22:30:03","guid":{"rendered":"http:\/\/www.constructionspecifier.com\/?p=15131"},"modified":"2017-01-20T14:52:12","modified_gmt":"2017-01-20T19:52:12","slug":"raising-the-argument-for-tall-wood-buildings","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/","title":{"rendered":"Raising the argument for tall wood buildings"},"content":{"rendered":"<figure id=\"attachment_15137\" aria-describedby=\"caption-attachment-15137\" style=\"width: 800px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg\" rel=\"attachment wp-att-15137\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-15137\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg\" alt=\"All images courtesy mgb Architecture+Design and Equilibrium Consulting \" width=\"800\" height=\"398\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg 800w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT-300x149.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT-768x382.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT-624x310.jpg 624w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/a><figcaption id=\"caption-attachment-15137\" class=\"wp-caption-text\"><em><span style=\"font-size: 8pt;\">All images courtesy mgb Architecture+Design and Equilibrium Consulting<\/span><\/em><\/figcaption><\/figure>\n<p>Before the end of the 19<sup>th<\/sup> century, wood was commonly used as a primary building material in several types of non-residential structures. Demonstrating the durability and strength of building with wood, many of these timber-built structures remain in use. Some date as far back as the seventh century, such as the 32.5-m (106-ft) high Horyu-ji Temple in Nara, Japan.<\/p>\n<p>In the late 1800s and early 1900s, significant advances in steel and reinforced concrete technology enabled the construction of landmark projects\u2014such as the Eiffel Tower and high-rises in New York City and Chicago. This established steel and concrete as the default structural materials for large buildings. Concurrently, light wood-frame construction gained popularity in the residential sector. While losing ground as the primary choice in commercial applications, it became the defacto material for home-builders.<\/p>\n<p>Over the past few decades, timber technology has seen advances and a transformative evolution. Factors contributing to making timber a technically versatile and economically competitive material include:<\/p>\n<ul>\n<li>new engineered wood products;<\/li>\n<li>computer-numerical-controlled (CNC) fabrication;<\/li>\n<li>versatile high-efficiency timber connectors; and<\/li>\n<li>progress in fire engineering.<\/li>\n<\/ul>\n<figure id=\"attachment_15139\" aria-describedby=\"caption-attachment-15139\" style=\"width: 422px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/10075-Structural-Concept-2011-03-11-11_ab.jpg\" rel=\"attachment wp-att-15139\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-15139\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/10075-Structural-Concept-2011-03-11-11_ab.jpg\" alt=\"These images show close-up examples of a solid wood panel core and intersecting ductile steel link beams in a wood building standing one to 12 stories. \" width=\"422\" height=\"141\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/10075-Structural-Concept-2011-03-11-11_ab.jpg 1584w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/10075-Structural-Concept-2011-03-11-11_ab-300x100.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/10075-Structural-Concept-2011-03-11-11_ab-768x256.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/10075-Structural-Concept-2011-03-11-11_ab-1000x334.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/10075-Structural-Concept-2011-03-11-11_ab-624x208.jpg 624w\" sizes=\"auto, (max-width: 422px) 100vw, 422px\" \/><\/a><figcaption id=\"caption-attachment-15139\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">These images show close-up examples of a solid wood panel core and intersecting ductile steel link beams in a wood building standing one to 12 stories.<\/span><\/figcaption><\/figure>\n<p>Further motivated by a desire to build structures with a smaller carbon and energy footprint, architects and engineers increasingly consider wood as an alternative for the construction of large-scale, non-residential structures such as educational facilities, museums, airports, and stadiums.<\/p>\n<p>In the context of tall wood buildings, the introduction of solid wood panel or mass timber construction has had the biggest impact. Developed in Europe 15 years ago, panel construction is quickly making headway in North American building. This new framing method involves the assembly of large, prefabricated engineered wood panels in either platform or balloon framing arrangements. Panel construction is often mixed with post-and-beam, and floor assemblies often include a concrete topping, sometimes made composite with floor panels to achieve greater strength, rigidity, vibration, and sound transmission performance.<\/p>\n<p>The potential of solid wood panel construction has quickly been recognized and design teams around the world have begun to work on concepts for the construction of mid- and high-rise timber structures. Last March, a report sponsored by British Columbia\u2019s Wood Enterprise Coalition (WEC) entitled \u201cTall Wood\u201d introduced a structural concept using solid wood panel construction, called \u2018Finding the Forest Through the Trees\u2019 (FFTT). Unlike most other timber high-rise concepts, FFTT was developed for high-seismic areas using Vancouver design data, and does not rely on a concrete core. Preliminary 3-D finite element analysis of 12-, 20-, and 30-story frames has validated the system\u2019s capability for timber high-rises in seismic zones.<\/p>\n<p><b>Solid wood panel construction<\/b><br \/>\nSolid wood panel construction does not refer to a specific product type, but to a construction method involving the assembly of large wood panels to form structures. There are six basic panel types available in Europe, which can be broken down into proprietary products. They include edge- or cross-laminated panels, either nailed, dowelled, or glued under pressure. In North America, engineered wood panel products\u2014such as laminated strand lumber (LSL) and laminated veneer lumber (LVL)\u2014have also been employed in projects. The most widely used panel type is the glued version of cross-laminated timber (CLT). (For more on cross-laminated timber, see the article, \u201cThe Coming of Cross-laminated Timber,\u201d by Lisa Podesto, PE, in the September 2011 issue of <a href=\"http:\/\/www.constructionspecifier.com\" target=\"_blank\"><i>The <\/i><i>Construction Specifier<\/i><\/a>.)<\/p>\n<p>In the United States and Canada, glued CLT panels are currently produced by suppliers in maximum sizes of 3 m (9.8 ft) in width, 13 m (43 ft), in length and up to 309 mm (12 in.) in thickness. LSL and LVL panels are typically produced in billets of 1.22 or 2.44 m (4 or 8 ft) in width, 19.5 m (64 m) in length, and up to 89 mm (3.5 in.) in thickness. They must be block-laminated together to achieve thicker panels.<\/p>\n<p><!--nextpage--><\/p>\n<figure id=\"attachment_15148\" aria-describedby=\"caption-attachment-15148\" style=\"width: 300px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT1_COMPOSITE_EDIT.jpg\" rel=\"attachment wp-att-15148\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-15148\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT1_COMPOSITE_EDIT-300x255.jpg\" alt=\"A representation of a 12-story \u2018Finding the Forest Through the Trees\u2019 (FFTT) building utilizing wood core walls and glued-laminated timber (glulam) perimeter columns for supporting the structure.\" width=\"300\" height=\"255\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT1_COMPOSITE_EDIT-300x255.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT1_COMPOSITE_EDIT-768x654.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT1_COMPOSITE_EDIT-624x531.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT1_COMPOSITE_EDIT.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-15148\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">A representation of a 12-story \u2018Finding the Forest Through the Trees\u2019 (FFTT) building utilizing wood core walls and glued-laminated timber (glulam) perimeter columns for supporting the structure.<\/span><\/figcaption><\/figure>\n<p>While the thought of a 30-story tower built in wood may at first appear impractical or even impossible,\u00a0a simple comparison shows the strength of engineered wood panels sometimes exceeds that of a typically reinforced concrete wall of similar thickness in all critical loading orientations. (Typical concrete high-rise design details are included in the \u201cTall Wood\u201d report for comparative purposes.) As wood is a quarter of the weight of concrete, a completed timber high-rise will be between one-third and one-half a concrete building\u2019s weight, resulting in a very advantageous strength-to-weight ratio. Structurally, the remaining challenge is to develop an assembly that not only performs well, but will also be efficient to fabricate\u00a0and erect.<\/p>\n<p>Different panel types have various material properties and will be better-suited for different applications. In the WEC report, examples illustrate LSL or LVL being specified for wall elements (because of the availability of longer panels and the fiber\u2019s homogeneous orientation), and CLT for floor panels, as they are more affordable and in thicker sizes.<\/p>\n<p><b>Codes<\/b><br \/>\nOver the past century, the majority of established building codes implicitly refer to light wood-frame construction with a \u2018combustible\u2019 or \u2018non-combustible\u2019 designation, which is used to prescribe maximum building size and height. Heavy timber construction\u00a0is referred to as an acceptable alternative to non-combustible construction and granted a fire-resistance rating, but it nevertheless remains largely limited by its combustibility classification.<\/p>\n<figure id=\"attachment_15149\" aria-describedby=\"caption-attachment-15149\" style=\"width: 250px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT2_COMPOSITE_EDIT.jpg\" rel=\"attachment wp-att-15149\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-15149\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT2_COMPOSITE_EDIT-204x300.jpg\" alt=\"Representation of a 20-story FFTT design using structural wood core walls, glulam perimeter columns, and interior structural wood walls.\" width=\"250\" height=\"368\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT2_COMPOSITE_EDIT-204x300.jpg 204w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT2_COMPOSITE_EDIT.jpg 543w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/><\/a><figcaption id=\"caption-attachment-15149\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">Representation of a 20-story FFTT design using structural wood core walls, glulam perimeter columns, and interior structural wood walls.<\/span><\/figcaption><\/figure>\n<p>Different wood species \u2018char\u2019 at specific and consistent rates. This char layer acts as a protective coating for the timber underneath. National Research Council (NRC) is currently carrying out tests on CLT, LVL, and LSL panels to confirm char rates, which to date have been based on European guidance. The fire-resistance rating can be adjusted to the required 60, 90, or 120 minutes by varying member thickness.<\/p>\n<p>As a result, the maximum height of timber buildings has been decreasing over the early half of the 20<sup>th<\/sup> century, from around eight stories in North America, when heavy timber post-and-beam was predominant, to a low point of three stories in the 1950s, when light wood-frame became the primary wood-based construction method. Over the past few decades, this trend has been reversing, primarily due to improvements in fire engineering and protection systems. Several jurisdictions in North America and Europe now allow light wood-frame construction up to five or six stories. For example, some of the locations allowing wood buildings up to five stories include:<\/p>\n<ul>\n<li>Portland, Oregon;<\/li>\n<li>Seattle, Washington;<\/li>\n<li>Las Vegas, Nevada; and<\/li>\n<li>the State of California.<\/li>\n<\/ul>\n<p>Recently, there has been recognition various timber construction systems perform differently in fire and should no longer necessarily be grouped together under the limiting \u2018combustible\u2019 category. As heavy post-and-beam construction performs significantly better than exposed light wood-frame, solid-wood panel construction has been shown in fire tests to be in a category of its own, and a performance-based approach to fire-resistance capability is being increasingly promoted around the globe. Austria, England, and Norway have already removed their height limitation on timber construction.<\/p>\n<figure id=\"attachment_15170\" aria-describedby=\"caption-attachment-15170\" style=\"width: 200px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT3_COMPOSITE_EDIT.jpg\" rel=\"attachment wp-att-15170\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-15170 size-medium\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT3_COMPOSITE_EDIT-200x300.jpg\" alt=\"Representation of a 20-story FFTT building employing structural wood core walls and exterior structural wood walls.\" width=\"200\" height=\"300\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT3_COMPOSITE_EDIT-200x300.jpg 200w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT3_COMPOSITE_EDIT.jpg 534w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/a><figcaption id=\"caption-attachment-15170\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">Representation of a 20-story FFTT building employing structural wood core walls and exterior structural wood walls.<\/span><\/figcaption><\/figure>\n<p>Last year in Canada, NRC formed the Wood and Wood-hybrid Mid-rise Building Committee to review options to do the same. Cities such as Chicago are taking the lead in the United States, where the creation of urban regions encouraging high-rise timber buildings\u2014or \u2018Green Building Zones\u2019 as referred to by NRC\u2014are currently being mooted.<\/p>\n<p><b>FFTT system<\/b><br \/>\nUsing the inherent vertical strength of solid wood panel construction, FFTT is based on the \u2018strong column\/weak beam\u2019 concept. Solid wood panels are connected together to form wall elements continuous over the building\u2019s height structure (balloon-framed) and linked together by highly ductile Class I shaped steel beams. Class I members develop full plastic movement capacity without buckling, behave in a predictable manner, and allow the development of plastic hinges, which efficiently dissipate energy in an earthquake. The system is used to form an arrangement of linked shear walls or perimeter moment-frames as required.<\/p>\n<p>The steel beams are partially imbedded and tight-fitted into the timber panels\u2019 face to simplify connection requirements. They are also proportioned to develop plastic hinges near the panel ends and provide sufficient strength and stiffness to resist all required loading conditions. The steel beams are locally shimmed in the critical bearing areas to avoid prying action and secured\u00a0to the panels using through-bolts. Reduced beam sections (RBS) can be employed to achieve the desired hinge locations and capacities while retaining the majority of the beam stiffness.<\/p>\n<p><!--nextpage--><\/p>\n<figure id=\"attachment_15173\" aria-describedby=\"caption-attachment-15173\" style=\"width: 169px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT4_COMPOSITE_EDIT.jpg\" rel=\"attachment wp-att-15173\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-15173\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT4_COMPOSITE_EDIT-169x300.jpg\" alt=\"Representation of a 30-story FFTT design with structural wood-core walls, structural wood interior walls, and structural wood exterior walls.\" width=\"169\" height=\"300\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT4_COMPOSITE_EDIT-169x300.jpg 169w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/OPT4_COMPOSITE_EDIT.jpg 450w\" sizes=\"auto, (max-width: 169px) 100vw, 169px\" \/><\/a><figcaption id=\"caption-attachment-15173\" class=\"wp-caption-text\">Representation of a 30-story FFTT design with structural wood-core walls, structural wood interior walls, and structural wood exterior walls.<\/figcaption><\/figure>\n<p>Vertical-panel joints are lapped and connected over the full height with self-tapping screws, building additional ductility into the system. Horizontal-panel joints can be efficiently achieved using wood-to-wood shear keys and timber-rivet tension connections at each end. Wall ends can be reinforced with localized panel thickenings. A variety of state-of-the-art connection systems can be specified to resist base forces.<\/p>\n<p>The floor\/diaphragm system may consist of CLT panels, with or without concrete topping, and column elements can be of glued-laminated timber (glulam)\u00a0or parallel strand lumber. The steel link beams act as ledgers or beams where present and engineered wood beams can be used elsewhere.<\/p>\n<p>Preliminary <a href=\"http:\/\/www.wecbc.ca\" target=\"_blank\">cost comparisons<\/a> between concrete and mass timber towers carried out for 12-, 20- and 30-story structures indicate the cost of mass timber construction is comparable to standard concrete construction, depending on location and whether fire resistance is achieved using encapsulation or charring.<\/p>\n<p><b>Conclusion<\/b><br \/>\nBy 2050, the United Nations (UN) predicts the global need for the construction of three billion residential units. As the construction and operation of buildings already accounts for about 50 percent of the total energy footprint, it will become increasingly critical structures are energy-efficient, and are built with less energy-demanding and polluting materials.<\/p>\n<figure id=\"attachment_15174\" aria-describedby=\"caption-attachment-15174\" style=\"width: 192px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/TallWood-FFTT.jpg\" rel=\"attachment wp-att-15174\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-15174\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/TallWood-FFTT-192x300.jpg\" alt=\"This is an external representation of a tall wood building designed using the FFTT model.\" width=\"192\" height=\"300\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/TallWood-FFTT-192x300.jpg 192w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/TallWood-FFTT.jpg 426w\" sizes=\"auto, (max-width: 192px) 100vw, 192px\" \/><\/a><figcaption id=\"caption-attachment-15174\" class=\"wp-caption-text\"><span style=\"font-size: 10pt;\">This is an external representation of a tall wood building designed using the FFTT model.<\/span><\/figcaption><\/figure>\n<p>Wood is the only major building material that\u00a0is renewable. Lifecycle assessment (LCA) studies consistently show wood products offer environmental advantages in terms of embodied energy, air\/water pollution, and greenhouse gas (GHG) emissions. Although a common concern is a rise in wood use means an increase in deforestation, recent data has shown overall tree cover is either being maintained or is increasing in all countries in the northern hemisphere where <a href=\"http:\/\/www.unece.org\/press\/pr2011\/11tim_p02e.html\" target=\"_blank\">forest management practices<\/a> are in effect.<\/p>\n<p>Forestry, the growing and harvesting of trees, and deforestation, the permanent removal of trees, are not synonymous. It is in the forest industry\u2019s best interest to re-forest, not de-forest, and good management practices are increasingly the norm around the world.<\/p>\n<p>Recent developments in timber technology have helped position wood as a viable, economical, durable, and sustainable option for almost any building type. Much analysis and testing work remains before a 20- or 30-story project can be implemented. However, this work is globally progressing at an impressive pace. The skylines of cities around the world may very soon include the first generation of timber high-rises.<\/p>\n<p><em>Eric Karsh M.Eng, P.Eng, StructEng, MIStructE, ing., began his consulting career in 1987 with Adjeleian Allen Rubeli Ltd., designers of the Rogers Centre stadium in Toronto.\u00a0In 1998, he co-founded the firm of Equilibrium Consulting which is now recognized internationally as a leader in the field of timber engineering. Over the last five years, Karsh has been actively involved in promoting solid wood construction as a viable, sustainable alternative to concrete construction. He has engineered numerous projects using various forms of solid wood construction. Karsh can be contacted via e-mail at info@eqcanada.com.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Before the end of the 19th century, wood was commonly used as a primary building material in several types of non-residential structures. Demonstrating the durability and strength of building with wood, many of these timber-built structures remain in use. <\/p>\n","protected":false},"author":10,"featured_media":15137,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,179,449,186,256,459],"tags":[2064,1314,2528,2523,2524,2525,2526,2527],"class_list":["post-15131","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-masterformat","category-uniformat","category-06-00-00-wood-plastics-and-composites","category-06-10-00-rough-carpentry","category-b10superstructure","tag-cross-laminated-timber","tag-division-06","tag-eric-karsh","tag-finding-the-forest-through-the-trees","tag-light-wood-frame-construction","tag-mass-timber-construction","tag-solid-wood-panel","tag-wood-enterprise-coalition","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Raising the argument for tall wood buildings - The Construction Specifier<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/\" \/>\n<link rel=\"next\" href=\"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Raising the argument for tall wood buildings - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Before the end of the 19th century, wood was commonly used as a primary building material in several types of non-residential structures. Demonstrating the durability and strength of building with wood, many of these timber-built structures remain in use.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2012-12-01T22:30:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-01-20T19:52:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"398\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Catherine Howlett\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Catherine Howlett\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/\"},\"author\":{\"name\":\"Catherine Howlett\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/26c86b4baf08f39a8684e1d14a8bc049\"},\"headline\":\"Raising the argument for tall wood buildings\",\"datePublished\":\"2012-12-01T22:30:03+00:00\",\"dateModified\":\"2017-01-20T19:52:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/\"},\"wordCount\":1999,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2012\\\/12\\\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg\",\"keywords\":[\"Cross-laminated timber\",\"Division 06\",\"Eric Karsh\",\"Finding the Forest Through the Trees\",\"Light wood-frame construction\",\"Mass timber construction\",\"Solid wood panel\",\"Wood Enterprise Coalition\"],\"articleSection\":[\"Features\",\"MasterFormat\",\"UniFormat\",\"06 00 00 Wood, Plastics, and Composites\",\"06 10 00 Rough Carpentry\",\"B10\u2212Superstructure\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/\",\"name\":\"Raising the argument for tall wood buildings - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2012\\\/12\\\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg\",\"datePublished\":\"2012-12-01T22:30:03+00:00\",\"dateModified\":\"2017-01-20T19:52:12+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/raising-the-argument-for-tall-wood-buildings\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2012\\\/12\\\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2012\\\/12\\\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg\",\"width\":800,\"height\":398,\"caption\":\"All images courtesy mgb Architecture+Design and Equilibrium Consulting\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/26c86b4baf08f39a8684e1d14a8bc049\",\"name\":\"Catherine Howlett\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g\",\"caption\":\"Catherine Howlett\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/catherine-howlett\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Raising the argument for tall wood buildings - The Construction Specifier","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/","next":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/2\/","og_locale":"en_US","og_type":"article","og_title":"Raising the argument for tall wood buildings - The Construction Specifier","og_description":"Before the end of the 19th century, wood was commonly used as a primary building material in several types of non-residential structures. Demonstrating the durability and strength of building with wood, many of these timber-built structures remain in use.","og_url":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/","og_site_name":"The Construction Specifier","article_published_time":"2012-12-01T22:30:03+00:00","article_modified_time":"2017-01-20T19:52:12+00:00","og_image":[{"width":800,"height":398,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg","type":"image\/jpeg"}],"author":"Catherine Howlett","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Catherine Howlett","Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/"},"author":{"name":"Catherine Howlett","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/26c86b4baf08f39a8684e1d14a8bc049"},"headline":"Raising the argument for tall wood buildings","datePublished":"2012-12-01T22:30:03+00:00","dateModified":"2017-01-20T19:52:12+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/"},"wordCount":1999,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg","keywords":["Cross-laminated timber","Division 06","Eric Karsh","Finding the Forest Through the Trees","Light wood-frame construction","Mass timber construction","Solid wood panel","Wood Enterprise Coalition"],"articleSection":["Features","MasterFormat","UniFormat","06 00 00 Wood, Plastics, and Composites","06 10 00 Rough Carpentry","B10\u2212Superstructure"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/","url":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/","name":"Raising the argument for tall wood buildings - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg","datePublished":"2012-12-01T22:30:03+00:00","dateModified":"2017-01-20T19:52:12+00:00","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/raising-the-argument-for-tall-wood-buildings\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2012\/12\/FFTT-OPT-1-2-INTERIOR-FLAT.jpg","width":800,"height":398,"caption":"All images courtesy mgb Architecture+Design and Equilibrium Consulting"},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/26c86b4baf08f39a8684e1d14a8bc049","name":"Catherine Howlett","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/83438974c404fdb0228df73d0965bdf6df5e5a153bd0283c7d2375da180a1582?s=96&d=mm&r=g","caption":"Catherine Howlett"},"url":"https:\/\/www.constructionspecifier.com\/author\/catherine-howlett\/"}]}},"views":16727,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/15131","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=15131"}],"version-history":[{"count":24,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/15131\/revisions"}],"predecessor-version":[{"id":25766,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/15131\/revisions\/25766"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/15137"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=15131"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=15131"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=15131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}