{"id":205577,"date":"2023-07-14T16:00:44","date_gmt":"2023-07-14T20:00:44","guid":{"rendered":"https:\/\/www.constructionspecifier.com\/?p=205577"},"modified":"2023-07-13T15:44:53","modified_gmt":"2023-07-13T19:44:53","slug":"optimizing-hvac-systems-to-decarbonize-buildings","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/","title":{"rendered":"Optimizing HVAC systems to decarbonize buildings"},"content":{"rendered":"<figure id=\"attachment_205578\" aria-describedby=\"caption-attachment-205578\" style=\"width: 326px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-205578\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-300x200.jpg\" alt=\"Photos courtesy ECM Technologies.\" width=\"326\" height=\"217\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-500x334.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-768x513.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies.jpg 800w\" sizes=\"auto, (max-width: 326px) 100vw, 326px\" \/><\/a><figcaption id=\"caption-attachment-205578\" class=\"wp-caption-text\"><span style=\"font-size: 9pt; font-family: arial, helvetica, sans-serif;\"><em>Photos courtesy ECM Technologies <\/em><\/span><\/figcaption><\/figure>\n<p><strong>By Michael Daly, PE<\/strong><\/p>\n<p>As the world continues to grapple with the effects of climate change, reducing greenhouse gas (GHG) emissions has become a top priority for governments, businesses, and individuals alike. One sector that has a significant impact on global emissions is commercial buildings. In fact, according to the International Energy Agency (IEA), commercial buildings are the fourth-largest emitters of CO2 globally.<\/p>\n<p>Within commercial buildings, HVAC systems are responsible for 67 percent of the total emissions emitted. This presents a major challenge for facility managers, who balance the day-to-day operational demands of their buildings with the need to reduce carbon footprints and energy costs. With HVAC systems playing such a crucial role in occupant comfort and energy consumption, decarbonizing these systems is key to achieving facility sustainability goals.<\/p>\n<p>Fortunately, new advanced technologies are being introduced to the industry that can help facility managers optimize their HVAC systems, save money, reduce emissions, and even extend equipment life. This article will explore one of the most common issues with commercial HVAC systems and how facility managers can not only remedy it, but also improve overall HVAC system performance which ultimately contributes to savings and less carbon emissions being emitted from the building.<\/p>\n<p><strong>The refrigerant-oil relationship<\/strong><\/p>\n<p>Before discussing a solution for improving the sustainability of HVAC systems, a clear understanding of the basic refrigerant-oil relationship is essential.<\/p>\n<figure id=\"attachment_205579\" aria-describedby=\"caption-attachment-205579\" style=\"width: 281px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-205579 \" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-1-300x200.jpg\" alt=\"New validated nano technologies offer facility managers an innovative way to restore lost efficiency and reduce carbon emissions.\" width=\"281\" height=\"187\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-1-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-1-500x333.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-1-768x512.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-1.jpg 800w\" sizes=\"auto, (max-width: 281px) 100vw, 281px\" \/><\/a><figcaption id=\"caption-attachment-205579\" class=\"wp-caption-text\"><span style=\"font-size: 9pt; font-family: arial, helvetica, sans-serif;\">New validated nano technologies offer facility managers an innovative way to restore lost efficiency and reduce carbon emissions.<\/span><\/figcaption><\/figure>\n<p>Refrigerants and oil play a crucial role in the operation of almost every HVAC system, other than oilless magnetic bearing systems. Refrigerants are responsible for absorbing and releasing heat, while oil lubricates the system\u2019s mechanical components to ensure smooth operation as well as dissipation of heat. Oil also works as a seal, minimizing compressed refrigerants from escaping from the compressor and ending up in the oil sump.<\/p>\n<p><!--nextpage--><\/p>\n<figure id=\"attachment_205580\" aria-describedby=\"caption-attachment-205580\" style=\"width: 202px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-205580 \" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-2-225x300.jpg\" alt=\"Oil-fouling is a common problem 99 percent of HVAC systems experience.\" width=\"202\" height=\"269\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-2-225x300.jpg 225w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-2-375x500.jpg 375w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-2.jpg 600w\" sizes=\"auto, (max-width: 202px) 100vw, 202px\" \/><\/a><figcaption id=\"caption-attachment-205580\" class=\"wp-caption-text\"><span style=\"font-size: 9pt; font-family: arial, helvetica, sans-serif;\">Oil-fouling is a common problem 99 percent of HVAC systems experience.<\/span><\/figcaption><\/figure>\n<p>The refrigerant-oil relationship is critical for maintaining system efficiency and preventing equipment breakdowns. Under normal circumstances, there will always be a small amount of oil that escapes a compressor\u2019s crankcase and is circulated with the refrigerant throughout the system. For this reason, refrigerant oil and the refrigerant itself must be miscible.<\/p>\n<p>The miscible mixture enables flowing refrigerant to continuously circulate oil through the system, returning most of the oil back to the compressor sump. However, over time, some of the oil begins to build up and form a thin film on the heat exchanger coils. This slow buildup of migrated oil is referred to as oil-fouling.<\/p>\n<p>Oil-fouling is a common problem 99 percent of HVAC systems experience, resulting in significant reduction of efficiency. Over time, the accumulation of oil and other contaminants in the system\u2019s heat exchanger can impede refrigerant flow, resulting in lower refrigerant velocity that compounds the problem of additional oil buildup. Inadequate refrigerant flow velocity enables oil to drop out of the flow, adhering to the heat exchanger coils. Additional oil buildup leads to poor heat transfer and decreased cooling capacity. This can result in equipment operating at 70 percent or less of its original capacity, leading to substantial energy loss and increased operating costs.<\/p>\n<p>The buildup of oil and other contaminants within the heat exchanger coils means less oil in the compressor sump. This insufficient amount of oil can cause the mechanical moving parts of the compressor to suffer higher frictional loads, which in return could lead to system breakdowns and increased maintenance costs. As such, addressing oil-fouling is a critical step toward optimizing HVAC system performance and reducing energy consumption.<\/p>\n<p><strong>Reclaiming lost efficiency<\/strong><\/p>\n<figure id=\"attachment_205581\" aria-describedby=\"caption-attachment-205581\" style=\"width: 329px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-205581\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-3-300x126.jpg\" alt=\"Oil fouling can leave HVAC systems units operating at 70 percent or less of their operating efficiency.\" width=\"329\" height=\"138\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-3-300x126.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-3-500x211.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-3-768x324.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-3.jpg 800w\" sizes=\"auto, (max-width: 329px) 100vw, 329px\" \/><\/a><figcaption id=\"caption-attachment-205581\" class=\"wp-caption-text\"><span style=\"font-size: 9pt; font-family: arial, helvetica, sans-serif;\">Oil fouling can leave HVAC systems units operating at 70 percent or less of their operating efficiency.<\/span><\/figcaption><\/figure>\n<p>To address the challenge posed by HVAC systems\u2019 energy consumption and their contribution to carbon emissions, new advanced technologies are being introduced. Material science advances are yielding HVAC performance gains through wear-resistant additives to refrigerant oils, combined with refrigerant specific stabilizers, which are essential to maintaining material properties for the life of the equipment.<\/p>\n<p>In addition to bolstering the refrigerant-specific oil properties, tailored additives that release oil from the heat exchanger surface also enable improved refrigerant velocities and strengthen heat transfer properties. These validated chemical cocktails offer facility managers an innovative way to restore lost efficiency and reduce carbon emissions.<\/p>\n<p><!--nextpage--><\/p>\n<figure id=\"attachment_205583\" aria-describedby=\"caption-attachment-205583\" style=\"width: 151px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-205583\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-5-200x300.jpg\" alt=\"(Image above and below) Effortless installation with zero system downtime simplifies the path to energy conservation and carbon reduction. \" width=\"151\" height=\"227\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-5-200x300.jpg 200w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-5-334x500.jpg 334w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-5.jpg 534w\" sizes=\"auto, (max-width: 151px) 100vw, 151px\" \/><\/a><figcaption id=\"caption-attachment-205583\" class=\"wp-caption-text\"><span style=\"font-size: 9pt; font-family: arial, helvetica, sans-serif;\">(Image above and below) Effortless installation with zero system downtime simplifies the path to energy conservation and carbon reduction. Significant operational savings, averaging 20 percent, can be achieved by employing performance-tested nano technology additives to combat oil fouling.<\/span><\/figcaption><\/figure>\n<p>Specific performance tested additives can reclaim 10 to 20 percent HVAC energy efficiency gains, and when coupled with extended equipment life, reduced maintenance, and deferred capital expenditures, operational savings can exceed 20 percent. Facilities personnel can achieve their goals of energy savings, operational cost savings, and extended equipment life that benefit capital budget plans as well.<\/p>\n<div class=\"mceTemp\"><\/div>\n<p><strong>The market perception of refrigerant and refrigerant oils<\/strong><\/p>\n<p>In the first few decades since the development of efficiency-improving formulations for refrigerants and refrigerant oils, the market has had mixed experiences with relatively poor adoption rates. Early attempts using solvents that degraded oil or formulations and included solids that negatively impacted expansion valves led to a persistent perception of \u201csnake oil.\u201d However, today, given advances in material science, the market is more receptive to newer technologies, moving away from the unproven formulations of the past. Trust is now earned by companies that offer professionally validated products with warranties.<\/p>\n<div class=\"mceTemp\"><\/div>\n<p><strong>Selecting the best materials<\/strong><\/p>\n<p>When looking to adapt new technology for an HVAC refrigerant system to reduce energy consumption and contribute to decarbonization, it is crucial to conduct proper due diligence and demand validated efficiency improvements. It is important to ensure the formulation of the technology is compatible with the specific equipment, refrigerant, and refrigerant oil. Despite that, many sales agents may not disclose or have knowledge of their respective chemistry, and most HVAC equipment managers are not chemists themselves, making assessments even more challenging. Therefore, it is advisable to seek credentialed validations and testing. Look for products that have been evaluated against American National Standards Institute (ANSI) standard compatibility tests and performance validated to ASHRAE or other accepted industry standards. By taking these steps, industry professionals can make informed decisions and select the most suitable technology for an HVAC system.<\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-205584 alignright\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-6-220x300.jpg\" alt=\"\" width=\"201\" height=\"274\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-6-220x300.jpg 220w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-6-366x500.jpg 366w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Image-6.jpg 586w\" sizes=\"auto, (max-width: 201px) 100vw, 201px\" \/>Conclusion<\/strong><\/p>\n<p>As the push for decarbonization continues to gain momentum, it is essential that facility managers take a closer look at the role HVAC systems play in emissions and energy consumption. By leveraging new technologies, they can improve the efficiency and sustainability of their buildings while also saving money in the process.<\/p>\n<p><strong>\u00a0<img loading=\"lazy\" decoding=\"async\" class=\" wp-image-205587 alignleft\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Daly_Headshot-f.jpg\" alt=\"\" width=\"107\" height=\"107\" \/>Author<\/strong><\/p>\n<p class=\"Sidebar-Bold\">Michael Daly, PE, chief technology officer at ECM Technologies, is a seasoned professional with more than 30 years of engineering and business management experience. He has made a career of developing, manufacturing, and selling lifesaving and life-changing technologies focused on energy conservation measures. Daly has a PE license in Arizona, with his BSME from the University of Arizona and executive education through the Harvard Business School Program for management development. <span style=\"letter-spacing: -.1pt;\">He also received his program management certification, PMP through the Project Management Institute (PMI), and is certified <\/span>in several quality methodologies.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Within commercial buildings, HVAC systems are responsible for 67 percent of the total emissions emitted. This presents a major challenge for facility managers, who balance the day-to-day operational demands of their buildings with the need to reduce carbon footprints and energy costs. <\/p>\n","protected":false},"author":29853,"featured_media":205586,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,179,197],"tags":[4407,2007,103,8685,601],"class_list":["post-205577","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-masterformat","category-23-00-00-heating-ventilating-and-air-conditioning-hvac","tag-23-00-00-heating-ventilating-and-air-conditioning","tag-carbon-emission-reduction","tag-hvac","tag-oil-fouling","tag-sustainability","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Optimizing HVAC systems to decarbonize buildings - The Construction Specifier<\/title>\n<meta name=\"description\" content=\"Within commercial buildings, HVAC systems are responsible for 67 percent of the total emissions emitted. There is the need to manage these.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/\" \/>\n<link rel=\"next\" href=\"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Optimizing HVAC systems to decarbonize buildings - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Within commercial buildings, HVAC systems are responsible for 67 percent of the total emissions emitted. There is the need to manage these.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-14T20:00:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-f.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"arslan_ahmed\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"arslan_ahmed\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/\"},\"author\":{\"name\":\"arslan_ahmed\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/e325f337715d3e25ed442febefc5e502\"},\"headline\":\"Optimizing HVAC systems to decarbonize buildings\",\"datePublished\":\"2023-07-14T20:00:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/\"},\"wordCount\":1230,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Photo-Credit_ECM-Technologies-f.jpg\",\"keywords\":[\"23 00 00\u2013Heating Ventilating and Air Conditioning\",\"Carbon Emission Reduction\",\"HVAC\",\"oil fouling\",\"Sustainability\"],\"articleSection\":[\"Features\",\"MasterFormat\",\"23 00 00 Heating, Ventilating, and Air Conditioning (HVAC)\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/\",\"name\":\"Optimizing HVAC systems to decarbonize buildings - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Photo-Credit_ECM-Technologies-f.jpg\",\"datePublished\":\"2023-07-14T20:00:44+00:00\",\"description\":\"Within commercial buildings, HVAC systems are responsible for 67 percent of the total emissions emitted. There is the need to manage these.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/optimizing-hvac-systems-to-decarbonize-buildings\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Photo-Credit_ECM-Technologies-f.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Photo-Credit_ECM-Technologies-f.jpg\",\"width\":400,\"height\":200},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/e325f337715d3e25ed442febefc5e502\",\"name\":\"arslan_ahmed\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8b3bc632ccc425475dad30606aef08d446e7b620e3a88e6fe3a7f806083c070b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8b3bc632ccc425475dad30606aef08d446e7b620e3a88e6fe3a7f806083c070b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8b3bc632ccc425475dad30606aef08d446e7b620e3a88e6fe3a7f806083c070b?s=96&d=mm&r=g\",\"caption\":\"arslan_ahmed\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/arslan_ahmed\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Optimizing HVAC systems to decarbonize buildings - The Construction Specifier","description":"Within commercial buildings, HVAC systems are responsible for 67 percent of the total emissions emitted. There is the need to manage these.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/","next":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/2\/","og_locale":"en_US","og_type":"article","og_title":"Optimizing HVAC systems to decarbonize buildings - The Construction Specifier","og_description":"Within commercial buildings, HVAC systems are responsible for 67 percent of the total emissions emitted. There is the need to manage these.","og_url":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/","og_site_name":"The Construction Specifier","article_published_time":"2023-07-14T20:00:44+00:00","og_image":[{"width":400,"height":200,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-f.jpg","type":"image\/jpeg"}],"author":"arslan_ahmed","twitter_card":"summary_large_image","twitter_misc":{"Written by":"arslan_ahmed","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/"},"author":{"name":"arslan_ahmed","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/e325f337715d3e25ed442febefc5e502"},"headline":"Optimizing HVAC systems to decarbonize buildings","datePublished":"2023-07-14T20:00:44+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/"},"wordCount":1230,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-f.jpg","keywords":["23 00 00\u2013Heating Ventilating and Air Conditioning","Carbon Emission Reduction","HVAC","oil fouling","Sustainability"],"articleSection":["Features","MasterFormat","23 00 00 Heating, Ventilating, and Air Conditioning (HVAC)"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/","url":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/","name":"Optimizing HVAC systems to decarbonize buildings - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-f.jpg","datePublished":"2023-07-14T20:00:44+00:00","description":"Within commercial buildings, HVAC systems are responsible for 67 percent of the total emissions emitted. There is the need to manage these.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/optimizing-hvac-systems-to-decarbonize-buildings\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-f.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2023\/07\/Photo-Credit_ECM-Technologies-f.jpg","width":400,"height":200},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/e325f337715d3e25ed442febefc5e502","name":"arslan_ahmed","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/8b3bc632ccc425475dad30606aef08d446e7b620e3a88e6fe3a7f806083c070b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8b3bc632ccc425475dad30606aef08d446e7b620e3a88e6fe3a7f806083c070b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8b3bc632ccc425475dad30606aef08d446e7b620e3a88e6fe3a7f806083c070b?s=96&d=mm&r=g","caption":"arslan_ahmed"},"url":"https:\/\/www.constructionspecifier.com\/author\/arslan_ahmed\/"}]}},"views":8329,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/205577","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/29853"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=205577"}],"version-history":[{"count":5,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/205577\/revisions"}],"predecessor-version":[{"id":205593,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/205577\/revisions\/205593"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/205586"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=205577"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=205577"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=205577"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}