{"id":210986,"date":"2024-06-12T11:17:04","date_gmt":"2024-06-12T15:17:04","guid":{"rendered":"https:\/\/www.constructionspecifier.com\/?p=210986"},"modified":"2025-02-12T14:53:00","modified_gmt":"2025-02-12T19:53:00","slug":"historic-masonry-unreinforced-parapet-walls","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/","title":{"rendered":"Parapet walls: Over the top"},"content":{"rendered":"<figure id=\"attachment_210987\" aria-describedby=\"caption-attachment-210987\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-210987 size-full\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-scaled.jpg\" alt=\"A weathered brick wall with a partially exposed red-brick section, set against a clear blue sky. Bare tree branches extend across the frame, some covered in frost.\" width=\"1024\" height=\"768\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-scaled.jpg 1024w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-300x225.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-500x375.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-768x576.jpg 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-210987\" class=\"wp-caption-text\">Figure 1: The brick masonry parapet wall is displaced and leaning outward at the building corners. <em>Photos courtesy Wiss, Janney, Elstner Associates (WJE)<\/em><\/figcaption><\/figure>\n<p>Historic masonry buildings often have unreinforced parapet walls, which lack vertical reinforcing in walls made of continuous multi-wythe masonry and capped with coping. Commonly used masonry materials include clay brick, stone, cast stone, terra cotta, clay tile, and concrete masonry units (CMUs), with lateral ties or reinforcing (if present) possibly extending between wythes, particularly in walls of multiple materials. In some historic buildings with projecting cornices below the parapet, the parapet wall\u2019s mass may help counterbalance the cornice.<\/p>\n<p>As these wall assemblies age and weather, routine assessments should be made for potential distress signs, including wall leaning or bowing, extensive masonry or mortar joint cracking, and displacement or deflection near corners and at structural framing. If observed, investigations are needed to identify the distress causes and develop appropriate repairs. Parapet wall distress may stem from unaddressed expansive or cyclical thermal stresses, material deterioration, or severe weather or seismic events.<\/p>\n<p>Masonry materials can expand and contract at significantly varying rates depending on the material, and differential expansion can accumulate over time. Differential movement between dissimilar materials may lead to mortar joint cracking and wall leaning. For instance, in a brick masonry parapet wall with stone cladding, the brick masonry backup\u2019s expansion might surpass that of the more stable stone cladding, causing the parapet wall to crack and lean outward. Material expansion might also cause displacement at building corners if not restrained by control joints. A recent project showed that insufficient corner restraint led to parapet leaning (Figure 1). Conditions linked to horizontal expansion can include vertical cracking, buckling, or parapet wall leaning.<\/p>\n<figure id=\"attachment_210988\" aria-describedby=\"caption-attachment-210988\" style=\"width: 800px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-210988 size-full\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-2.jpg\" alt=\"\" width=\"800\" height=\"600\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-2.jpg 800w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-2-300x225.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-2-500x375.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-2-768x576.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/a><figcaption id=\"caption-attachment-210988\" class=\"wp-caption-text\">Corrosion of the steel lateral anchor resulted in spalling at the rear face of the stone cladding unit, which then displaced outward away from the brick masonry backup.<\/figcaption><\/figure>\n<p>Weathering can deteriorate parapet walls over time, making them particularly vulnerable due to multi-directional weather exposure. Water penetration can corrode embedded steel in elements such as lateral ties, lintels, shelf angles, or anchors. A recent project showed how corrosion of lateral anchors led to spalling and displacement of stone cladding unit (Figure 2). Corroding steel expands, potentially pushing or lifting adjacent masonry, causing cracks, bowing, or leaning where corrosion occurs. Masonry saturation can cause freeze-thaw damage, such as spalling and cracking of masonry units, weakening the wall system\u2019s structural integrity over time (Figure 3).<\/p>\n<figure id=\"attachment_210989\" aria-describedby=\"caption-attachment-210989\" style=\"width: 800px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-210989 size-full\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-3.jpg\" alt=\"\" width=\"800\" height=\"600\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-3.jpg 800w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-3-300x225.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-3-500x375.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-3-768x576.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/a><figcaption id=\"caption-attachment-210989\" class=\"wp-caption-text\">The inner wythe of clay masonry in this parapet was found to be severely deteriorated due to freeze-thaw.<\/figcaption><\/figure>\n<p>Besides issues tied to materials and construction, unreinforced parapet walls are more prone to failure from natural events like earthquakes, high winds, excessive rainfall, and flying debris during severe weather.<\/p>\n<p>To determine an appropriate approach for repair, investigations must identify distress mechanisms and document the existing wall and roof structure, including concealed conditions. Repair options might include removal and rebuilding or in-place bracing, stabilizing, and repairing. Depending on the distress\u2019s cause and extent, other methods, such as installing pins for missing or deteriorated lateral anchorage, may be considered. Any selected repair design should be performed in accordance with applicable standards to meet the anticipated wind, seismic, and other loads.<\/p>\n<h2>Authors<\/h2>\n<p><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Itle_Headshot.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-210991 size-thumbnail\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Itle_Headshot-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" \/><\/a><\/p>\n<p>Kenneth Itle, AIA, is an architect and associate principal with Wiss, Janney, Elstner Associates (WJE) in Northbrook, Illinois, specializing in historic preservation. He can be reached at kitle@wje.com.<\/p>\n<p><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Ford_Headshot.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-210992 size-thumbnail\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Ford_Headshot-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" \/><\/a><\/p>\n<p>Mike Ford is an architect and senior associate with Wiss, Janney, Elstner Associates (WJE) in Northbrook, Illinois. He specializes in facade assessment and cleaning. He can be reached at mford@wje.com.<\/p>\n<p>The opinions expressed in Failures are based on the authors\u2019 experiences and do not necessarily reflect that of <em>The Construction Specifier<\/em> or CSI.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Historic masonry buildings often have unreinforced parapet walls, which lack vertical reinforcing in walls made of continuous multi-wythe masonry and capped with coping.<\/p>\n","protected":false},"author":34186,"featured_media":210990,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9,24],"tags":[80],"class_list":["post-210986","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-columns","category-failures","tag-failures-2","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Parapet walls: Over the top - The Construction Specifier<\/title>\n<meta name=\"description\" content=\"Historic masonry buildings often have unreinforced parapet walls, which lack vertical reinforcing in walls made of continuous multi-wythe masonry and capped with coping.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Parapet walls: Over the top - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Historic masonry buildings often have unreinforced parapet walls, which lack vertical reinforcing in walls made of continuous multi-wythe masonry and capped with coping.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2024-06-12T15:17:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-12T19:53:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-F.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"tanya_martins\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"tanya_martins\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/\"},\"author\":{\"name\":\"tanya_martins\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/2fce6c78e0d75dca19e94a5df6b1ff6a\"},\"headline\":\"Parapet walls: Over the top\",\"datePublished\":\"2024-06-12T15:17:04+00:00\",\"dateModified\":\"2025-02-12T19:53:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/\"},\"wordCount\":645,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/Figure-1-F.jpg\",\"keywords\":[\"failures\"],\"articleSection\":[\"Columns\",\"Failures\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/\",\"name\":\"Parapet walls: Over the top - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/Figure-1-F.jpg\",\"datePublished\":\"2024-06-12T15:17:04+00:00\",\"dateModified\":\"2025-02-12T19:53:00+00:00\",\"description\":\"Historic masonry buildings often have unreinforced parapet walls, which lack vertical reinforcing in walls made of continuous multi-wythe masonry and capped with coping.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/Figure-1-F.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/Figure-1-F.jpg\",\"width\":400,\"height\":200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/historic-masonry-unreinforced-parapet-walls\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Parapet walls: Over the top\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/2fce6c78e0d75dca19e94a5df6b1ff6a\",\"name\":\"tanya_martins\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g\",\"caption\":\"tanya_martins\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/tanya_martins\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Parapet walls: Over the top - The Construction Specifier","description":"Historic masonry buildings often have unreinforced parapet walls, which lack vertical reinforcing in walls made of continuous multi-wythe masonry and capped with coping.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/","og_locale":"en_US","og_type":"article","og_title":"Parapet walls: Over the top - The Construction Specifier","og_description":"Historic masonry buildings often have unreinforced parapet walls, which lack vertical reinforcing in walls made of continuous multi-wythe masonry and capped with coping.","og_url":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/","og_site_name":"The Construction Specifier","article_published_time":"2024-06-12T15:17:04+00:00","article_modified_time":"2025-02-12T19:53:00+00:00","og_image":[{"width":400,"height":200,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-F.jpg","type":"image\/jpeg"}],"author":"tanya_martins","twitter_card":"summary_large_image","twitter_misc":{"Written by":"tanya_martins","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/"},"author":{"name":"tanya_martins","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/2fce6c78e0d75dca19e94a5df6b1ff6a"},"headline":"Parapet walls: Over the top","datePublished":"2024-06-12T15:17:04+00:00","dateModified":"2025-02-12T19:53:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/"},"wordCount":645,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-F.jpg","keywords":["failures"],"articleSection":["Columns","Failures"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/","url":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/","name":"Parapet walls: Over the top - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-F.jpg","datePublished":"2024-06-12T15:17:04+00:00","dateModified":"2025-02-12T19:53:00+00:00","description":"Historic masonry buildings often have unreinforced parapet walls, which lack vertical reinforcing in walls made of continuous multi-wythe masonry and capped with coping.","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-F.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2025\/02\/Figure-1-F.jpg","width":400,"height":200},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/historic-masonry-unreinforced-parapet-walls\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"Parapet walls: Over the top"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/2fce6c78e0d75dca19e94a5df6b1ff6a","name":"tanya_martins","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g","caption":"tanya_martins"},"url":"https:\/\/www.constructionspecifier.com\/author\/tanya_martins\/"}]}},"views":10813,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/210986","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/34186"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=210986"}],"version-history":[{"count":1,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/210986\/revisions"}],"predecessor-version":[{"id":210993,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/210986\/revisions\/210993"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/210990"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=210986"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=210986"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=210986"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}