{"id":213326,"date":"2025-12-31T09:39:16","date_gmt":"2025-12-31T14:39:16","guid":{"rendered":"https:\/\/www.constructionspecifier.com\/?p=213326"},"modified":"2026-01-05T09:45:04","modified_gmt":"2026-01-05T14:45:04","slug":"strutting-about","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/strutting-about\/","title":{"rendered":"Strutting about"},"content":{"rendered":"<figure id=\"attachment_213330\" aria-describedby=\"caption-attachment-213330\" style=\"width: 509px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-213330 size-full\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1.jpg\" alt=\"\" width=\"509\" height=\"305\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1.jpg 509w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1-300x180.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1-500x300.jpg 500w\" sizes=\"auto, (max-width: 509px) 100vw, 509px\" \/><\/a><figcaption id=\"caption-attachment-213330\" class=\"wp-caption-text\">Figure 1: Water flowing from a hole drilled at the base of a fractured strut, in which the drainage hole was sealed during the past sealant replacement program. <em>Photos courtesy Wiss, Janney, Elstner Associates (WJE)<\/em><\/figcaption><\/figure>\n<p>It is well established that construction materials exposed to exterior environmental conditions can be susceptible to freeze-thaw damage, particularly in climate zones with frequent and concurrent wetting and freeze-thaw cycles. Freeze-thaw distress is typically associated with critically saturated, absorptive materials such as concrete and masonry. However, damage can also occur in non-porous systems during freeze-thaw cycling when water becomes trapped internally, resulting in volumetric expansion that can exert significant pressure on surrounding components.<\/p>\n<p>An example of this situation was encountered during a condition assessment of a geodesic dome structure. The dome\u2019s exterior structural framework consisted of a hexagonal array of exposed tubular aluminum struts welded to end plates, which were bolted to node assemblies through folded aluminum panels forming the cladding. Several struts had developed full-thickness longitudinal fractures, raising questions about the cause of the failure and the structural integrity of the affected struts. The fractures were isolated to the bottom ends of the struts and at the lower elevations of the dome, where the struts sloped more steeply.<\/p>\n<p>The original design incorporated sealant at cladding panel joints and gaskets below the strut end plates to mitigate water infiltration. Each strut also included a large fabrication hole centered in the upper end plate (beneath the open end of the hexagonal strut) and a drainage hole on the underside of the lower end.<\/p>\n<figure id=\"attachment_213331\" aria-describedby=\"caption-attachment-213331\" style=\"width: 800px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-213331 size-full\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture2.jpg\" alt=\"\" width=\"800\" height=\"599\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture2.jpg 800w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture2-300x225.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture2-500x374.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture2-768x575.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/a><figcaption id=\"caption-attachment-213331\" class=\"wp-caption-text\">Figure 2: Fractured weld connection between strut and strut end plate.<\/figcaption><\/figure>\n<p>To address recurring water leakage, a previous repair campaign replaced the sealant protecting the exposed exterior joints\u2014an effort that was not overly successful. The remedial sealant application was found to be poorly executed, with systemic deficiencies including improper profiles and tooling, cohesive and adhesive bond failures, and areas where new sealant was thinly applied directly over the original failed sealant. Additionally, many of the dedicated drainage holes at the base of the struts had been covered with sealant.<\/p>\n<p>Noting that several of the damaged struts exhibited water staining at the bottom tips of the fractures, exploratory holes were drilled into the base of several affected struts. Each released a significant volume of trapped water, indicating that water had migrated into the struts through the fabrication hole at the upper end plate via breaches in the seals and original gaskets, and had accumulated at the base due to blocked drainage holes. Cyclic freezing and thawing of the confined column of water within the near-vertical struts exerted expansive pressures that fractured the struts and several of their connections to the end plates. In comparison, the near-horizontal struts located higher on the dome did not exhibit fractures, as water infiltration did not fill the circumference of those members, resulting in lower confined expansive forces. This finding alleviated previously held structural concerns regarding the long-term fatigue performance of the dome.<\/p>\n<p>Remediation efforts included replacing the fractured struts, reestablishing the dedicated drainage holes, and replacing the sealant. This example highlights the importance of fully understanding failure mechanisms so that repairs intended to address one condition do not inadvertently cause another. In this case, a lack of awareness of the intended water-management approach within the original structural assembly led to blocked drainage provisions, ultimately resulting in strut fractures.<\/p>\n<h2>Author<\/h2>\n<p><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Jeff-Sutterlin_headshot.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-213327 size-thumbnail\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Jeff-Sutterlin_headshot-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" \/><\/a><\/p>\n<p>Jeffrey Sutterlin, P.E., is an architectural engineer and associate principal with Wiss, Janney, Elstner Associates (WJE) in the New York and Princeton offices. He specializes in the investigation and repair of building enclosures, as well as peer review and consulting for new enclosure design. He can be reached at jsutterlin@wje.com.<\/p>\n<p><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Patterson-Photo.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-213328 size-thumbnail\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Patterson-Photo-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" \/><\/a><\/p>\n<p>David S. Patterson, AIA, is an architect and senior principal with Wiss, Janney, Elstner Associates (WJE) in Princeton, N.J. He specializes in the investigation and repair of building enclosures, as well as peer review and consulting for new enclosure designs. He can be reached at dpatterson@wje.com.<\/p>\n<p><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Statler_Headshot.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-213329 size-thumbnail\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Statler_Headshot-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" \/><\/a><\/p>\n<p>Dale Statler is a structural engineer and senior associate with Wiss, Janney, Elstner Associates (WJE) in Denver, Colo. He specializes in the investigation, analysis, and repair of existing and damaged structures. He can be reached at dstatler@wje.com.<\/p>\n<p>The opinions expressed in Failures are based on the authors\u2019 experiences and do not necessarily reflect that of <em>The<\/em> <em>Construction Specifier <\/em>or CSI.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>To address recurring water leakage, a previous repair campaign replaced the sealant protecting the exposed exterior joints\u2014an effort that was not overly successful.<\/p>\n","protected":false},"author":34186,"featured_media":213330,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9,24],"tags":[96],"class_list":["post-213326","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-columns","category-failures","tag-failure","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Strutting about - The Construction Specifier<\/title>\n<meta name=\"description\" content=\"To address recurring water leakage, a previous repair campaign replaced the sealant protecting the exposed exterior joints\u2014an effort that was not overly successful.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/strutting-about\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Strutting about - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"To address recurring water leakage, a previous repair campaign replaced the sealant protecting the exposed exterior joints\u2014an effort that was not overly successful.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/strutting-about\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-31T14:39:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-05T14:45:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"509\" \/>\n\t<meta property=\"og:image:height\" content=\"305\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"tanya_martins\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"tanya_martins\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/\"},\"author\":{\"name\":\"tanya_martins\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/2fce6c78e0d75dca19e94a5df6b1ff6a\"},\"headline\":\"Strutting about\",\"datePublished\":\"2025-12-31T14:39:16+00:00\",\"dateModified\":\"2026-01-05T14:45:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/\"},\"wordCount\":741,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Picture1.jpg\",\"keywords\":[\"failure\"],\"articleSection\":[\"Columns\",\"Failures\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/\",\"name\":\"Strutting about - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Picture1.jpg\",\"datePublished\":\"2025-12-31T14:39:16+00:00\",\"dateModified\":\"2026-01-05T14:45:04+00:00\",\"description\":\"To address recurring water leakage, a previous repair campaign replaced the sealant protecting the exposed exterior joints\u2014an effort that was not overly successful.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Picture1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Picture1.jpg\",\"width\":509,\"height\":305},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/strutting-about\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Strutting about\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/2fce6c78e0d75dca19e94a5df6b1ff6a\",\"name\":\"tanya_martins\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g\",\"caption\":\"tanya_martins\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/tanya_martins\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Strutting about - The Construction Specifier","description":"To address recurring water leakage, a previous repair campaign replaced the sealant protecting the exposed exterior joints\u2014an effort that was not overly successful.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/strutting-about\/","og_locale":"en_US","og_type":"article","og_title":"Strutting about - The Construction Specifier","og_description":"To address recurring water leakage, a previous repair campaign replaced the sealant protecting the exposed exterior joints\u2014an effort that was not overly successful.","og_url":"https:\/\/www.constructionspecifier.com\/strutting-about\/","og_site_name":"The Construction Specifier","article_published_time":"2025-12-31T14:39:16+00:00","article_modified_time":"2026-01-05T14:45:04+00:00","og_image":[{"width":509,"height":305,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1.jpg","type":"image\/jpeg"}],"author":"tanya_martins","twitter_card":"summary_large_image","twitter_misc":{"Written by":"tanya_martins","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/"},"author":{"name":"tanya_martins","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/2fce6c78e0d75dca19e94a5df6b1ff6a"},"headline":"Strutting about","datePublished":"2025-12-31T14:39:16+00:00","dateModified":"2026-01-05T14:45:04+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/"},"wordCount":741,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1.jpg","keywords":["failure"],"articleSection":["Columns","Failures"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/strutting-about\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/","url":"https:\/\/www.constructionspecifier.com\/strutting-about\/","name":"Strutting about - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1.jpg","datePublished":"2025-12-31T14:39:16+00:00","dateModified":"2026-01-05T14:45:04+00:00","description":"To address recurring water leakage, a previous repair campaign replaced the sealant protecting the exposed exterior joints\u2014an effort that was not overly successful.","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/strutting-about\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/01\/Picture1.jpg","width":509,"height":305},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/strutting-about\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"Strutting about"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/2fce6c78e0d75dca19e94a5df6b1ff6a","name":"tanya_martins","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e2c04a5d7eab5107347f73e92112a5c08e05d787b4cf5fe113518f61234fa266?s=96&d=mm&r=g","caption":"tanya_martins"},"url":"https:\/\/www.constructionspecifier.com\/author\/tanya_martins\/"}]}},"views":4702,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/213326","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/34186"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=213326"}],"version-history":[{"count":2,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/213326\/revisions"}],"predecessor-version":[{"id":213333,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/213326\/revisions\/213333"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/213330"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=213326"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=213326"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=213326"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}