{"id":215728,"date":"2026-11-06T07:10:15","date_gmt":"2026-11-06T12:10:15","guid":{"rendered":"https:\/\/www.constructionspecifier.com\/?p=215728"},"modified":"2026-11-09T10:13:51","modified_gmt":"2026-11-09T15:13:51","slug":"modern-masonry-meets-energy-codes","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/","title":{"rendered":"Modern masonry meets energy codes"},"content":{"rendered":"<figure id=\"attachment_215738\" aria-describedby=\"caption-attachment-215738\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-215738\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg\" alt=\"Modern two-storey red brick house with flat roofs and large dark shutters, surrounded by a manicured lawn, shrubs, and a patio with wooden chairs.\" width=\"1024\" height=\"683\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg 1024w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-500x334.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-768x512.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-1536x1025.jpg 1536w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-1568x1046.jpg 1568w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-215738\" class=\"wp-caption-text\"><em>Photo \u00a9 Bohdan Stocek\/Unsplash<\/em><\/figcaption><\/figure>\n<p>As energy codes become more rigorous, traditional masonry construction faces new challenges in meeting thermal performance requirements. New methods are needed to meet thermal requirements without compromising structural integrity or project economics.<\/p>\n<p>Advanced continuous insulation (c.i.) strategies, high-performance cavity innovations, and thermal bridge mitigation through low-conductivity anchoring systems enable masonry assemblies to meet <em>International Energy Conservation Code<\/em> (<em>IECC<\/em>) <em>2021<\/em> and ASHRAE 90.1-2019 requirements, while maintaining the durability and aesthetic benefits specifiers value in masonry construction.<\/p>\n<h2>The three paths to compliance<\/h2>\n<p><a href=\"http:\/\/codes.iccsafe.org\/content\/IECC2021V3.0\/chapter-4-ce-commercial-energy-efficiency\"><em>IECC 2021<\/em> establishes stringent thermal performance requirements<\/a> for opaque wall assemblies based on climate zones. Designers should verify which code edition, whether 2018 or 2021, is locally enforced, as requirements can differ. Nonetheless, the trend is toward higher R-values and c.i. in all climate zones. These performance targets, often more than 80 percent of the annual baseline energy cost, need careful attention to assembly design and material selection.<\/p>\n<p>The regulations recognize that different projects require different compliance strategies. The codes establish three distinct pathways that allow specifiers to choose the approach best suited to their project\u2019s complexity, design const, and performance goals. Understanding these options enables informed decisions early in the design process when changes remain cost-effective.<\/p>\n<figure id=\"attachment_215731\" aria-describedby=\"caption-attachment-215731\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/connie-de-vries-5bBpnTpg5po-unsplash-1-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-215731\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/connie-de-vries-5bBpnTpg5po-unsplash-1-scaled.jpg\" alt=\"Detail of a brick facade mixing red and cream bricks in varied patterns, with two narrow windows with bright blue blinds under a blue sky.\" width=\"1024\" height=\"683\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/connie-de-vries-5bBpnTpg5po-unsplash-1-scaled.jpg 1024w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/connie-de-vries-5bBpnTpg5po-unsplash-1-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/connie-de-vries-5bBpnTpg5po-unsplash-1-500x333.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/connie-de-vries-5bBpnTpg5po-unsplash-1-768x512.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/connie-de-vries-5bBpnTpg5po-unsplash-1-1536x1024.jpg 1536w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/connie-de-vries-5bBpnTpg5po-unsplash-1-1568x1045.jpg 1568w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-215731\" class=\"wp-caption-text\">Building codes establish minimum anchor spacing based on wall height and exposure conditions. <em>Photo \u00a9 Connie De Vries\/Unsplash<\/em><\/figcaption><\/figure>\n<h5>Path 1: The prescriptive method<\/h5>\n<p>The prescriptive method establishes minimum R-values for individual building components based on the climate zone. For masonry mass walls, this approach specifies either minimum c.i. values or cavity insulation values that must be met or exceeded.<\/p>\n<p>This path offers straightforward compliance verification through plan review and field inspection. Code officials can quickly confirm specified materials meet minimum requirements without complex calculations. However, the prescriptive method provides limited flexibility for design optimization or trade-offs between building systems. Every component must meet its individual requirement regardless of how other assemblies perform.<\/p>\n<h5>Path 2: The component performance method<\/h5>\n<p>The component performance approach allows trade-offs between building envelope components, provided the overall assembly performance matches or exceeds prescriptive requirements. This method calculates a building\u2019s total UA (overall heat transfer coefficient) and compares it against the UA that would result from prescriptive compliance. If the proposed design\u2019s UA equals or falls below the baseline, the project demonstrates compliance.<\/p>\n<p>COMcheck software streamlines this analysis by automating calculations and providing immediate feedback on proposed assemblies. A specifier might propose masonry walls slightly below the prescriptive R-values if they are offset by enhanced window performance, reduced air infiltration, or superior roof insulation. This flexibility enables designers to optimize for specific project conditions, architectural requirements, or budget constraints while maintaining code-compliant energy performance.<\/p>\n<h5>Path 3: The total building performance method<\/h5>\n<p>The total building performance path evaluates annual energy consumption for the entire building using approved energy modeling software. This approach compares a proposed design against a baseline building that meets prescriptive requirements. If the proposed design consumes the same amount of energy or less energy than the baseline, it demonstrates compliance regardless of how individual components perform.<\/p>\n<p>This method offers maximum design flexibility, particularly valuable for complex projects incorporating renewable energy systems, advanced mechanical equipment, or innovative envelope strategies. Energy modeling can show that even a masonry wall with a lower R-value may comply when the design compensates with high-efficiency HVAC, optimized glazing placement, or the thermal mass effect of masonry. However, this path requires specialized expertise, detailed building information, and significantly more analysis time than prescriptive or component performance methods.<\/p>\n<h2>Evaluating the pros and cons of each path<\/h2>\n<p>Selecting the appropriate compliance path depends on project complexity, design priorities, and available resources. Each approach offers distinct advantages and limitations that influence both the design process and construction outcomes.<\/p>\n<p>For most masonry projects, the component performance path offers an optimal balance between design flexibility and analysis complexity. Projects incorporating advanced masonry strategies, such as high-performance cavity insulation or thermally broken anchoring systems, can particularly benefit from this approach. These innovations can offset requirements elsewhere in the envelope. High-performance systems with thicker insulation and specialty ties do raise initial costs, but energy modeling often shows a reasonable payback within a few years.<\/p>\n<figure id=\"attachment_215732\" aria-describedby=\"caption-attachment-215732\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/jason-leung-YBNa23W7-3E-unsplash-1-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-215732\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/jason-leung-YBNa23W7-3E-unsplash-1-scaled.jpg\" alt=\"Weathered concrete wall painted partly white beside a red brick wall, with a narrow strip of blue sky between them.\" width=\"1024\" height=\"683\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/jason-leung-YBNa23W7-3E-unsplash-1-scaled.jpg 1024w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/jason-leung-YBNa23W7-3E-unsplash-1-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/jason-leung-YBNa23W7-3E-unsplash-1-500x333.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/jason-leung-YBNa23W7-3E-unsplash-1-768x512.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/jason-leung-YBNa23W7-3E-unsplash-1-1536x1024.jpg 1536w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/jason-leung-YBNa23W7-3E-unsplash-1-1568x1045.jpg 1568w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-215732\" class=\"wp-caption-text\">The prescriptive method for modern masonry establishes minimum R-values for individual building components based on the climate zone. For masonry mass walls, this approach specifies either c.i. values or cavity insulation values that must be met or exceeded. <em>Photo \u00a9 Jason Leung\/Unsplash<\/em><\/figcaption><\/figure>\n<h2>Continuous insulation strategies for code compliance<\/h2>\n<p>Continuous insulation (c.i.) is the most reliable approach for achieving IECC compliance in masonry assemblies. Installed across the entire wall surface without penetrations from structural members, c.i. eliminates thermal bridges that compromise cavity-only insulation performance. <a href=\"http:\/\/polyiso.org\/page\/InstallationHowItImpactsR-Value\">For instance, cavity insulation provides only about 45 percent of its rated R-value<\/a>\u00a0in steel-framed walls without c.i.<\/p>\n<h5>Exterior continuous insulation<\/h5>\n<p>Exterior c.i. provides superior thermal performance by positioning the insulation layer outside the structural masonry wythe. This placement keeps the structural elements at moderate temperatures, reducing thermal stress and improving long-term durability. Rigid foam boards, such as extruded polystyrene, polyisocyanurate (polyiso), or mineral wool, offer appropriate R-values. Architects must also ensure that exterior insulation assemblies in commercial walls meet fire performance codes, such as NFPA 285, Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components, for foam plastic insulation.<\/p>\n<p>Installation typically involves mechanically fastening foam boards to the backup wythe, then supporting the exterior masonry veneer with adjustable anchors that penetrate through the insulation layer. The thickness of exterior c.i. can be adjusted to meet climate-specific requirements without altering the cavity dimension. This approach offers significant advantages for moisture management:<\/p>\n<ul>\n<li>Condensation control\u2014exterior insulation maintains the backup wall above the dew point during cold weather, substantially reducing condensation risk.<\/li>\n<li>Thermal stress reduction\u2014keeping structural elements at moderate temperatures improves long-term durability.<\/li>\n<li>Simplified flashing details\u2014through-wall flashing and drainage-plane integration are easier than with interior c.i. alternatives.<\/li>\n<\/ul>\n<figure id=\"attachment_215734\" aria-describedby=\"caption-attachment-215734\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/solomen-i6V6diaf71A-unsplash-1-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-215734\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/solomen-i6V6diaf71A-unsplash-1-scaled.jpg\" alt=\"Close-up of a mason's hands spreading mortar with a trowel onto a freshly laid row of grey concrete blocks.\" width=\"1024\" height=\"683\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/solomen-i6V6diaf71A-unsplash-1-scaled.jpg 1024w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/solomen-i6V6diaf71A-unsplash-1-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/solomen-i6V6diaf71A-unsplash-1-500x333.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/solomen-i6V6diaf71A-unsplash-1-768x512.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/solomen-i6V6diaf71A-unsplash-1-1536x1024.jpg 1536w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/solomen-i6V6diaf71A-unsplash-1-1568x1045.jpg 1568w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-215734\" class=\"wp-caption-text\">Increasingly strict energy codes are challenging traditional masonry construction methods to meet thermal performance requirements without compromising structural integrity or project economics.\u00a0<em>Photo \u00a9 Solomen\/Unsplash<\/em><\/figcaption><\/figure>\n<h5>Interior continuous insulation options<\/h5>\n<p>Interior c.i. involves applying rigid foam or spray foam to the interior surface of the masonry backup wall. This strategy works well in renovation projects where historic preservation requirements or site constraints limit exterior modifications. Closed-cell spray polyurethane foam provides both insulation value and air sealing in a single application. Advanced modeling tools now help specifiers predict condensation and thermal bridging, ensuring designs avoid moisture issues, which is valuable for interior insulation.<\/p>\n<p>The primary challenges with interior c.i. are managing moisture and preventing condensation on cold masonry surfaces. In heating-dominated climates, interior insulation can trap moisture within the masonry if vapor control strategies are insufficient. Specifiers must carefully evaluate vapor permeance and ensure adequate drainage between wythes (e.g. through weep holes and flashing).<\/p>\n<p>Rigid foam boards combined with resilient metal furring channels offer another interior approach. This assembly creates space for mechanical and electrical distribution. The air gap between the foam and interior finish provides additional thermal resistance if properly detailed to prevent air circulation.<\/p>\n<h2>Hybrid insulation approaches<\/h2>\n<p>Combining c.i. with high-performance cavity insulation delivers optimal thermal performance for masonry assemblies in severe climate zones. A 101.6-mm (4-in.) cavity filled with semi-rigid mineral wool (R-16) plus 50.8 mm (2 in.) of exterior polyiso (R-13) yields a total of R-29. This value exceeds IECC mass wall requirements for Climate Zones 7 and 8 while also meeting the R-13 and R-15 c.i. requirement for steel-framed walls in Zone 8, all while maintaining reasonable wall thickness.<\/p>\n<p>The hybrid insulation strategy also addresses thermal bridging through structural connections. Low-conductivity anchors and thermally broken shelf angles become essential components in these high-performance assemblies. In addition to c.i., enhancements within the cavity can also boost performance, as described next.<\/p>\n<h2>Advanced cavity wall innovations<\/h2>\n<p>The space between masonry wythes offers an opportunity to enhance thermal performance when detailed correctly. Traditional cavity wall construction creates a drainage plane that manages moisture effectively while accommodating insulation materials. Modern innovations in cavity insulation materials and installation techniques enable assemblies to achieve code compliance without c.i. in moderate climate zones.<\/p>\n<h2>High-performance cavity insulation materials<\/h2>\n<p>Semi-rigid mineral wool batts designed specifically for masonry cavities offer superior performance compared to traditional fiberglass:<\/p>\n<ul>\n<li>High thermal resistance\u2014R-values up to R-4.3 per inch in cavity applications.<\/li>\n<li>Dimensional stability\u2014material will not slump over time in vertical installations, ensuring consistent performance throughout the building life cycle.<\/li>\n<li>Moisture resistance\u2014resists moisture absorption while maintaining vapor permeability for cavity drainage.<\/li>\n<li>Durability\u2014maintains integrity under freeze-thaw cycling and temperature extremes.<\/li>\n<\/ul>\n<p>Installation requires careful attention to ensure complete cavity filling without compression or gaps. Friction-fit mineral wool batts sized 6.4 mm (0.25 in.) wider than the cavity dimension compress slightly during installation, maintaining contact with both wythes. Cutting batts to fit around anchors and ensuring tight joints at horizontal reinforcing can prevent thermal bypass that could compromise overall assembly performance.<\/p>\n<p>Hydrophobic treatment on mineral wool products prevents water absorption and supports vapor permeability. This characteristic allows the cavity to serve as a drainage plane even with insulation in place. Water that penetrates the exterior wythe drains down the back face without accumulating in the insulation material.<\/p>\n<h2>Specifying faced or unfaced insulation in the cavity<\/h2>\n<p>Moisture management in masonry cavities influences the selection of insulation facing. Unfaced mineral wool generally performs better in cavity applications because it allows vapor to move freely in both directions. This permeability helps the assembly dry when moisture enters from either side. Faced insulation with vapor retarders can trap moisture against the backup wythe, potentially leading to condensation issues.<\/p>\n<p>However, certain climates benefit from strategic vapor control. In mixed-humid climates where both heating and cooling seasons impose significant loads, <a href=\"http:\/\/spi-co.com\/roller\/SPIBlog\/entry\/best-applications-for-faced-vs\">faced installation allows for moisture control in exterior walls<\/a>.\u00a0Still, positioning requires careful analysis of vapor-drive direction throughout the year.<\/p>\n<p>Air barriers integrated with cavity insulation can improve thermal performance when detailed correctly. Manual air-sealing techniques <a href=\"http:\/\/gsa.gov\/governmentwide-initiatives\/federal-highperformance-buildings\/highperformance-building-clearinghouse\/emerging-technology-evaluations\/building-envelope\/automated-building-envelope-sealing\">can tighten a building envelope by about six to 17 percent<\/a>, reducing leakage compared to assemblies without explicit sealing measures. The air barrier should be continuous, sealed at penetrations, and integrated with window and door rough opening details.<\/p>\n<h2>Optimizing cavity width for maximum thermal resistance<\/h2>\n<p>Cavity width directly impacts achievable R-value and construction feasibility. However, wider cavities introduce structural considerations for anchoring systems. As cavity width increases, anchor length and flexural demands also increase. The distance between wythes affects load transfer mechanics and requires careful evaluation. Adjustable anchors with extended length ranges accommodate wider cavities while maintaining structural adequacy.<\/p>\n<p>Construction tolerances also factor into decisions about cavity width. A nominally 101.6-mm (4-in.) cavity may vary from 88.9 mm to 114.3 mm (3.5 in. to 4.5 in) across a wall surface due to normal masonry dimensional variation. Specifying insulation that accommodates this tolerance range without compression or gaps ensures there is consistent thermal performance.<\/p>\n<h2>Thermal bridge mitigation through advanced anchoring<\/h2>\n<p>Metal anchors and shelf angles connecting masonry wythes create thermal bridges that significantly compromise assembly R-value. Standard steel anchors provide high tensile strength but conduct heat readily, creating cold spots on interior surfaces and degrading overall thermal performance. Advanced anchoring systems using low-conductivity materials and thermally broken designs address these concerns without decreasing structural integrity.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"95\"><strong>Compliance Path<\/strong><\/td>\n<td width=\"192\"><strong>Advantages<\/strong><\/td>\n<td width=\"191\"><strong>Limitations<\/strong><\/td>\n<td width=\"194\"><strong>Best For<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"95\"><strong>Prescriptive Method<\/strong><\/td>\n<td width=\"192\"><strong>\u2022<\/strong><br \/>\nSimple verification process<strong>\u2022<\/strong><br \/>\nClear requirements<strong>\u2022<\/strong><br \/>\nFast plan review<strong>\u2022<\/strong><br \/>\nMinimal analysis required<\/td>\n<td width=\"191\"><strong>\u2022<\/strong><br \/>\nNo design flexibility<strong>\u2022<\/strong><br \/>\nComponent compliance required<strong>\u2022<\/strong><br \/>\nCannot leverage trade-offs<strong>\u2022<\/strong><br \/>\nMay require oversizing<\/td>\n<td width=\"194\"><strong>\u2022<\/strong><br \/>\nStraightforward projects<strong>\u2022<\/strong><br \/>\nStandard construction<strong>\u2022<\/strong><br \/>\nLimited design team resources<strong>\u2022<\/strong><br \/>\nFast-track schedules<\/td>\n<\/tr>\n<tr>\n<td width=\"95\"><strong>Component Performance Method<\/strong><\/td>\n<td width=\"192\"><strong>\u2022<\/strong><br \/>\nAllows trade-offs between envelope components<strong>\u2022<\/strong><br \/>\nFaster than energy modeling<strong>\u2022<\/strong><br \/>\nAccommodates budget constraints<strong>\u2022<\/strong><br \/>\nCOMcheck software simplifies analysis<\/td>\n<td width=\"191\"><strong>\u2022<\/strong><br \/>\nLimited to envelope trade-offs<strong>\u2022<\/strong><br \/>\nCannot credit mechanical systems<strong>\u2022<\/strong><br \/>\nRequires basic energy calculations<strong>\u2022<\/strong><br \/>\nLess flexibility than a total building approach<\/td>\n<td width=\"194\"><strong>\u2022<\/strong><br \/>\nProjects with envelope<br \/>\ndesign constraints<strong>\u2022<\/strong><br \/>\nCost optimization needs<strong>\u2022<\/strong><br \/>\nArchitectural feature integration<strong>\u2022<\/strong><br \/>\nModerate complexity buildings<\/td>\n<\/tr>\n<tr>\n<td width=\"95\"><strong>Total Building Performance Method<\/strong><\/td>\n<td width=\"192\"><strong>\u2022<\/strong><br \/>\nMaximum design flexibility<strong>\u2022<\/strong><br \/>\nCredits all energy-saving measures<strong>\u2022<\/strong><br \/>\nEnables innovative strategies<strong>\u2022<\/strong><br \/>\nDemonstrates thermal<br \/>\nmass benefits<\/td>\n<td width=\"191\"><strong>\u2022<\/strong><br \/>\nRequires detailed energy modeling<strong>\u2022<\/strong><br \/>\nNeeds specialized expertise<strong>\u2022<\/strong><br \/>\nTime-intensive analysis<strong>\u2022<\/strong><br \/>\nComplex review process<\/td>\n<td width=\"194\"><strong>\u2022<\/strong><br \/>\nComplex buildings<strong>\u2022<\/strong><br \/>\nHigh-performance designs<strong>\u2022<\/strong><br \/>\nProjects with renewable energy<strong>\u2022<\/strong><br \/>\nInnovative envelope strategies<strong>\u2022<\/strong><br \/>\nSituations when thermal mass provides a significant benefit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Low-conductivity tie materials<\/h2>\n<p>Composite anchors manufactured from fiberglass-reinforced polymers or basalt fiber composites offer tensile strengths comparable to steel and offer dramatically reduced thermal conductivity. <a href=\"http:\/\/ualberta.scholaris.ca\/items\/b46d1967-7bea-4f43-907a-fcae33dce923\">Research shows that thermal bridging through ties can reduce<\/a> a wall\u2019s R-value by about 15 percent (with low-conductivity ties) to about 42 percent (with conventional steel ties), highlighting the significant impact of proper anchor specification. This variation directly translates into improved comfort and reduced energy consumption.<\/p>\n<p>Composite anchors meet structural requirements when specified correctly for the application. Testing protocols verify tensile capacity, shear resistance, and durability under freeze-thaw cycling. Specifiers should confirm that the selected composite anchors are accompanied by appropriate code evaluation reports demonstrating compliance with building code requirements. Installation procedures for composite anchors differ slightly from steel alternatives and require attention to several key factors:<\/p>\n<ul>\n<li>Embedment depth\u2014manufacturers specify minimum depths that may differ from steel anchor requirements.<\/li>\n<li>Hole diameter tolerances\u2014tighter tolerances prevent anchor rotation and ensure proper load transfer.<\/li>\n<li>Fastener torque specifications\u2014over-tightening can damage composite materials, while under-tightening compromises connection integrity.<\/li>\n<li>Mock-up panels\u2014preinstallation testing ensures field personnel understand proper techniques before full-scale installation.<\/li>\n<\/ul>\n<h2>Thermally broken shelf angle design<\/h2>\n<p>Shelf angles supporting masonry veneer at floor lines represent major thermal bridges in multi-story construction. A continuous steel angle spanning the building perimeter creates a direct conductive path between the interior and exterior environments. Thermal imaging frequently reveals these connections as cold bands on interior walls, often with associated condensation or mold growth.<\/p>\n<p>Thermally broken shelf angle systems interrupt this heat flow path with low-conductivity pads or structural thermal breaks. These components insert between the shelf angle and supporting structure, reducing conductive heat transfer while maintaining load-bearing capacity. Proprietary systems using rigid mineral wool or reinforced polymer pads may achieve significant improvements in thermal resistance compared to traditional direct-bearing details.<\/p>\n<p>Structural analysis becomes critical when specifying thermally broken shelf angles.<br \/>\nThe thermal break material must withstand bearing stress from the masonry veneer dead load, as well as any vertical loads from wind or seismic effects. The load-deflection characteristics of the thermal break influence long-term performance and should be evaluated during the design process.<\/p>\n<figure id=\"attachment_215736\" aria-describedby=\"caption-attachment-215736\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/wolfgang-weiser-XFuUjAZzv5A-unsplash-1-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-215736\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/wolfgang-weiser-XFuUjAZzv5A-unsplash-1-scaled.jpg\" alt=\"Dark red brick building with a row of sweeping white arches along its ground floor, gold-clad columns, and a deep blue sky above.\" width=\"1024\" height=\"683\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/wolfgang-weiser-XFuUjAZzv5A-unsplash-1-scaled.jpg 1024w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/wolfgang-weiser-XFuUjAZzv5A-unsplash-1-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/wolfgang-weiser-XFuUjAZzv5A-unsplash-1-500x333.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/wolfgang-weiser-XFuUjAZzv5A-unsplash-1-768x512.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/wolfgang-weiser-XFuUjAZzv5A-unsplash-1-1536x1024.jpg 1536w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/wolfgang-weiser-XFuUjAZzv5A-unsplash-1-1568x1045.jpg 1568w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-215736\" class=\"wp-caption-text\">As <em>IECC 2024<\/em> takes effect across jurisdictions, the trajectory toward more rigorous thermal performance standards is continuing.\u00a0<em>Photo \u00a9 Wolfgang Weiser<\/em><\/figcaption><\/figure>\n<h2>Adjustable anchoring systems<\/h2>\n<p>Adjustable anchors accommodate construction tolerances, thermal expansion, and the structural connection between wythes. These two-piece systems feature a base unit embedded in the backup wall and a pintle that adjusts both vertically and horizontally to engage the exterior wythe. This adjustability reduces installation complexity and accommodates wider insulation layers without custom anchor fabrication.<\/p>\n<p>Modern adjustable anchor designs incorporate thermal break elements within the connector assembly. By separating the metal components with polymer insulators or reducing the cross-sectional area of the conductive path, these systems minimize thermal bridging and preserve structural performance. Some manufacturers offer adjustable anchors in composite materials, combining thermal efficiency with installation flexibility. Using at least 101.6 mm (4 in.) thick exterior insulation calls for longer, adjustable anchors and alignment to maintain structural ties. Teams should coordinate cladding attachments and flashed openings to accommodate the insulation layer.<\/p>\n<p>Proper specification requires attention to anchor density, load capacity, and thermal performance. Building codes establish minimum anchor spacing based on wall height and exposure conditions. Denser anchor spacing improves structural capacity but increases thermal bridging, creating a balance point that requires analysis for each specific project condition.<\/p>\n<h2>Future outlook of code-compliant masonry design<\/h2>\n<p>As IECC 2024 takes effect across jurisdictions, the trajectory toward more rigorous thermal performance standards continues. IECC 2030 may drive masonry insulation requirements toward net-zero energy standards, potentially mandating continuous exterior insulation for most climate zones to eliminate thermal bridging effectively.<\/p>\n<p>Upcoming code cycles (IECC 2024 and beyond) present both challenges and opportunities for masonry construction. Material manufacturers continue developing lower-conductivity anchoring systems and higher-performance insulation products specifically engineered for masonry applications. Digital tools enabling thermal bridging analysis and moisture modeling have also become essential components of the design process. Specifiers who invest in understanding advanced masonry thermal performance strategies can prepare for increasingly demanding standards.<\/p>\n<h2>Key Takeaways<\/h2>\n<p>Increasingly strict energy codes, such as the <em>International Energy Conservation Code<\/em> (<em>IECC<\/em>) 2021\/2024 and ASHRAE 90.1, are pushing traditional masonry construction to adopt advanced continuous insulation (c.i.) and low-conductivity anchoring systems. To maintain structural integrity and aesthetic value without compromising project economics, specifiers must navigate multiple compliance pathways and prioritize thermal bridge mitigation to eliminate energy loss through cavity walls.<\/p>\n<h2>Author<\/h2>\n<p><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/Chambers_Headshot-1-e1794237205378.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-215739 size-thumbnail\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/Chambers_Headshot-1-e1794237205378-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/Chambers_Headshot-1-e1794237205378-150x150.jpg 150w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/Chambers_Headshot-1-e1794237205378-300x300.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/Chambers_Headshot-1-e1794237205378-500x500.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/Chambers_Headshot-1-e1794237205378.jpg 618w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><\/p>\n<p>Peter Chambers is an associate editor at <em>Renovated<\/em>, specializing in technical building science. He covers material selection, building envelope performance, and <em>IECC<\/em>\/ASHRAE energy code compliance.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Increasingly strict energy codes, such as the International Energy Conservation Code (IECC) 2021\/2024 and ASHRAE 90.1, are pushing traditional masonry construction to adopt advanced continuous insulation and low-conductivity anchoring systems.<\/p>\n","protected":false},"author":35591,"featured_media":215738,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,179,449,184,245,10246,489,460],"tags":[10247,83,10248,10249,1062],"class_list":["post-215728","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-masterformat","category-uniformat","category-04-00-00-masonry","category-04-20-00-unit-masonry","category-07-21-00-thermal-insulation","category-b2010exterior-walls","category-b20exterior-vertical-enclosures","tag-cavity-wall-assemblies","tag-continuous-insulation","tag-iecc-compliance","tag-modern-masonry","tag-thermal-bridging","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Modern masonry meets energy codes - The Construction Specifier<\/title>\n<meta name=\"description\" content=\"Increasingly strict energy codes are pushing traditional masonry construction to adopt advanced c.i. and low-conductivity anchoring systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Modern masonry meets energy codes - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Increasingly strict energy codes are pushing traditional masonry construction to adopt advanced c.i. and low-conductivity anchoring systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-06T12:10:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-09T15:13:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"amrit_bls\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"amrit_bls\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/\"},\"author\":{\"name\":\"amrit_bls\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/0c4de6fcfc742337de86ffbb2fb63778\"},\"headline\":\"Modern masonry meets energy codes\",\"datePublished\":\"2026-11-06T12:10:15+00:00\",\"dateModified\":\"2026-11-09T15:13:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/\"},\"wordCount\":2790,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg\",\"keywords\":[\"Cavity wall assemblies\",\"continuous insulation\",\"IECC compliance\",\"Modern masonry\",\"Thermal bridging\"],\"articleSection\":[\"Features\",\"MasterFormat\",\"UniFormat\",\"04 00 00 Masonry\",\"04 20 00 Unit Masonry\",\"07 21 00\u2013Thermal Insulation\",\"B2010\u2212Exterior Walls\",\"B20\u2212Exterior Vertical Enclosures\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/\",\"name\":\"Modern masonry meets energy codes - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg\",\"datePublished\":\"2026-11-06T12:10:15+00:00\",\"dateModified\":\"2026-11-09T15:13:51+00:00\",\"description\":\"Increasingly strict energy codes are pushing traditional masonry construction to adopt advanced c.i. and low-conductivity anchoring systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg\",\"width\":1024,\"height\":683,\"caption\":\"Photo \u00a9 Bohdan Stocek\\\/Unsplash\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/modern-masonry-meets-energy-codes\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Modern masonry meets energy codes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/0c4de6fcfc742337de86ffbb2fb63778\",\"name\":\"amrit_bls\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/224a29f848416e19f02b122ce7adec678f6616e1bef3ee1a2579445bf8d29427?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/224a29f848416e19f02b122ce7adec678f6616e1bef3ee1a2579445bf8d29427?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/224a29f848416e19f02b122ce7adec678f6616e1bef3ee1a2579445bf8d29427?s=96&d=mm&r=g\",\"caption\":\"amrit_bls\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/amrit_bls\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Modern masonry meets energy codes - The Construction Specifier","description":"Increasingly strict energy codes are pushing traditional masonry construction to adopt advanced c.i. and low-conductivity anchoring systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/","og_locale":"en_US","og_type":"article","og_title":"Modern masonry meets energy codes - The Construction Specifier","og_description":"Increasingly strict energy codes are pushing traditional masonry construction to adopt advanced c.i. and low-conductivity anchoring systems.","og_url":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/","og_site_name":"The Construction Specifier","article_published_time":"2026-11-06T12:10:15+00:00","article_modified_time":"2026-11-09T15:13:51+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg","type":"image\/jpeg"}],"author":"amrit_bls","twitter_card":"summary_large_image","twitter_misc":{"Written by":"amrit_bls","Est. reading time":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/"},"author":{"name":"amrit_bls","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/0c4de6fcfc742337de86ffbb2fb63778"},"headline":"Modern masonry meets energy codes","datePublished":"2026-11-06T12:10:15+00:00","dateModified":"2026-11-09T15:13:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/"},"wordCount":2790,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg","keywords":["Cavity wall assemblies","continuous insulation","IECC compliance","Modern masonry","Thermal bridging"],"articleSection":["Features","MasterFormat","UniFormat","04 00 00 Masonry","04 20 00 Unit Masonry","07 21 00\u2013Thermal Insulation","B2010\u2212Exterior Walls","B20\u2212Exterior Vertical Enclosures"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/","url":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/","name":"Modern masonry meets energy codes - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg","datePublished":"2026-11-06T12:10:15+00:00","dateModified":"2026-11-09T15:13:51+00:00","description":"Increasingly strict energy codes are pushing traditional masonry construction to adopt advanced c.i. and low-conductivity anchoring systems.","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2026\/11\/bohdan-stocek-J_pSdNTqncI-unsplash-1-scaled.jpg","width":1024,"height":683,"caption":"Photo \u00a9 Bohdan Stocek\/Unsplash"},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/modern-masonry-meets-energy-codes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"Modern masonry meets energy codes"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/0c4de6fcfc742337de86ffbb2fb63778","name":"amrit_bls","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/224a29f848416e19f02b122ce7adec678f6616e1bef3ee1a2579445bf8d29427?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/224a29f848416e19f02b122ce7adec678f6616e1bef3ee1a2579445bf8d29427?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/224a29f848416e19f02b122ce7adec678f6616e1bef3ee1a2579445bf8d29427?s=96&d=mm&r=g","caption":"amrit_bls"},"url":"https:\/\/www.constructionspecifier.com\/author\/amrit_bls\/"}]}},"views":315,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/215728","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/35591"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=215728"}],"version-history":[{"count":5,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/215728\/revisions"}],"predecessor-version":[{"id":215748,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/215728\/revisions\/215748"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/215738"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=215728"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=215728"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=215728"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}