{"id":406,"date":"2013-09-02T08:30:07","date_gmt":"2013-09-02T12:30:07","guid":{"rendered":"http:\/\/www.constructionspecifier.com\/?p=406"},"modified":"2014-02-28T10:12:03","modified_gmt":"2014-02-28T15:12:03","slug":"continuing-the-debate-on-solar-driven-moisture","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/","title":{"rendered":"Continuing the Debate on Solar-driven Moisture"},"content":{"rendered":"<p><i>Our January 2013 article, \u201c<a title=\"Construction Specifier January 2013 - pg 12\" href=\"http:\/\/www.kenilworth.com\/publications\/cs\/de\/201301\/files\/12.html\" target=\"_blank\">Ensuring Moisture Protection for Manufactured Stone<\/a>,\u201d <\/i> <i>written by Jeff Diqui, Arch. Eng., CSI, resulted in a letter to the editor from another frequent contributor to <\/i>The Construction Specifier<i>. <\/i><\/p>\n<p><i>In the spring, Maria Spinu, PhD, LEED AP, e-mailed her comments:<\/i><\/p>\n<p>I want to compliment Mr. Diqui on a generally well-written and informative article, but I wish to address the statements made around solar-driven moisture. He wrote:<\/p>\n<p>A related effect in adhered masonry veneer cladding is inward vapor drive, which can occur in warm weather. It forces moisture stored in the masonry through vapor-permeable housewraps and building papers and into the sheathing and stud bay.<!--more--><\/p>\n<p>While recognizing that vapor diffusion is not the only source of moisture in buildings (<i>i.e.<\/i> \u201cbulk water is not the only enemy\u201d), the author goes on to say that \u201canother challenge is inward water vapor drive \u2026 Bulk water intrusion and vapor drive have led to damage and rot in sheathing and structural members.\u201d Bulk water intrusion and solar-driven moisture in the same sentence? That\u2019s what got to me!<\/p>\n<p>I fully agree adhered masonry veneer is not the best practice\u2014incorporating a drainage plane and a ventilation gap in this wall assembly is much better. However, attributing condensation problems to solar-driven moisture is not supported by field research or advanced moisture analysis simulations. Multi-year field tests have unsuccessfully tried to reproduce solar-driven moisture effects in wall assemblies using weather-resistant barriers (WRBs) of different vapor permeance, but instead have found those materials\u2019 vapor permeance has little or no effect on solar-driven moisture.(See American Society of Heating, Refrigerating, and Air-conditioning Engineers [ASHRAE\u2019s] 2010 report, \u201cEvaluation of Cladding and Water-Resistive Barrier Performance in Hot-Humid Climates Using a Real-Weather, Real-Time Test Facility,\u201d by Theresa A. Weston et al.)<\/p>\n<p>ASHRAE TRP 1235, \u201cResearch Project on Solar-driven Moisture,\u201d found under conditions solar-driven moisture occurred, the critical wall component was not the WRB\u2019s vapor permeance, but rather the interior wall\u2019s vapor permeability\u2014in other words, use of interior vapor barriers in hot\/humid climates. (Synthesis of research project RP-1235, ASHRAE OR-10-061, \u201cThe Nature, Significance, and Control of Solar-driven Water Vapor Diffusion in Wall Systems,\u201d by D. Derome et al.)<\/p>\n<p>Condensation problems are very unlikely to be caused by inward vapor diffusion. Building scientists have long agreed more than 90 percent of moisture vapor transported through the building enclosure is due to air leakage, and only less than 10 percent can be attributed to vapor diffusion. The major source of water vapor in the building enclosure is infiltration of humid, exterior air that could lead to condensation if the exterior air reaches the cooler interior surfaces<\/p>\n<p>Advanced moisture simulations\u2014such as W\u00e4rme und Feuchte instation\u00e4r (WUFI) or Transient Heat and Moisture\u2014can estimate the condensation potential due to air infiltration. It has been shown if the humid exterior air reaches the cooler interior surfaces with temperatures below the exterior air dewpoint, it will deposit excess moisture and lead to condensations. (See the 2006 report, \u201cAssessing the Durability Impacts of Energy Efficient Enclosure Upgrades Using Hygrothermal Modeling: Research Report\u20130605,\u201d by John Straube and Christopher Schumacher.) In fact, most condensation problems attributed to vapor diffusion are likely due to moisture transported by air leakage.<\/p>\n<p>So, let\u2019s see the forest for the trees and focus on good design and execution. Vapor-permeable WRBs do not contribute to wetting in a properly designed building envelope. However, WRB vapor permeance is critical for efficient drying of any incidental moisture that makes its way behind the WRB where neither drainage nor ventilation is available for drying.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Our January 2013 article, \u201cEnsuring Moisture Protection for Manufactured Stone,\u201d written by Jeff Diqui, Arch. Eng., CSI, resulted in a letter to the editor from another frequent contributor to The Construction Specifier. In the spring, Maria Spinu, PhD, LEED AP, e-mailed her comments: I want to compliment Mr. Diqui on a generally well-written and informative&hellip; <a class=\"more-link\" href=\"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/\">Continue reading <span class=\"screen-reader-text\">Continuing the Debate on Solar-driven Moisture<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[2],"tags":[157,158,155,113,156,67,154,159],"class_list":["post-406","post","type-post","status-publish","format-standard","hentry","category-matter-of-spec","tag-cladding","tag-condensation","tag-manufactured","tag-masonry","tag-masonry-veneer","tag-moisture","tag-stone","tag-wufi","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Continuing the Debate on Solar-driven Moisture - The Construction Specifier<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Continuing the Debate on Solar-driven Moisture - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Our January 2013 article, \u201cEnsuring Moisture Protection for Manufactured Stone,\u201d written by Jeff Diqui, Arch. Eng., CSI, resulted in a letter to the editor from another frequent contributor to The Construction Specifier. In the spring, Maria Spinu, PhD, LEED AP, e-mailed her comments: I want to compliment Mr. Diqui on a generally well-written and informative&hellip; Continue reading Continuing the Debate on Solar-driven Moisture\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2013-09-02T12:30:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2014-02-28T15:12:03+00:00\" \/>\n<meta name=\"author\" content=\"eyetee\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"eyetee\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/continuing-the-debate-on-solar-driven-moisture\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/continuing-the-debate-on-solar-driven-moisture\\\/\"},\"author\":{\"name\":\"eyetee\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/27a8ccc930cede4eeb25c6a121d87bc5\"},\"headline\":\"Continuing the Debate on Solar-driven Moisture\",\"datePublished\":\"2013-09-02T12:30:07+00:00\",\"dateModified\":\"2014-02-28T15:12:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/continuing-the-debate-on-solar-driven-moisture\\\/\"},\"wordCount\":597,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"keywords\":[\"Cladding\",\"condensation\",\"manufactured\",\"Masonry\",\"masonry veneer\",\"moisture\",\"stone\",\"WUFI\"],\"articleSection\":[\"Matter of Spec\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/continuing-the-debate-on-solar-driven-moisture\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/continuing-the-debate-on-solar-driven-moisture\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/continuing-the-debate-on-solar-driven-moisture\\\/\",\"name\":\"Continuing the Debate on Solar-driven Moisture - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"datePublished\":\"2013-09-02T12:30:07+00:00\",\"dateModified\":\"2014-02-28T15:12:03+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/continuing-the-debate-on-solar-driven-moisture\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/continuing-the-debate-on-solar-driven-moisture\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/continuing-the-debate-on-solar-driven-moisture\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Continuing the Debate on Solar-driven Moisture\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/27a8ccc930cede4eeb25c6a121d87bc5\",\"name\":\"eyetee\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g\",\"caption\":\"eyetee\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/eyetee\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Continuing the Debate on Solar-driven Moisture - The Construction Specifier","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/","og_locale":"en_US","og_type":"article","og_title":"Continuing the Debate on Solar-driven Moisture - The Construction Specifier","og_description":"Our January 2013 article, \u201cEnsuring Moisture Protection for Manufactured Stone,\u201d written by Jeff Diqui, Arch. Eng., CSI, resulted in a letter to the editor from another frequent contributor to The Construction Specifier. In the spring, Maria Spinu, PhD, LEED AP, e-mailed her comments: I want to compliment Mr. Diqui on a generally well-written and informative&hellip; Continue reading Continuing the Debate on Solar-driven Moisture","og_url":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/","og_site_name":"The Construction Specifier","article_published_time":"2013-09-02T12:30:07+00:00","article_modified_time":"2014-02-28T15:12:03+00:00","author":"eyetee","twitter_card":"summary_large_image","twitter_misc":{"Written by":"eyetee","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/"},"author":{"name":"eyetee","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/27a8ccc930cede4eeb25c6a121d87bc5"},"headline":"Continuing the Debate on Solar-driven Moisture","datePublished":"2013-09-02T12:30:07+00:00","dateModified":"2014-02-28T15:12:03+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/"},"wordCount":597,"commentCount":1,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"keywords":["Cladding","condensation","manufactured","Masonry","masonry veneer","moisture","stone","WUFI"],"articleSection":["Matter of Spec"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/","url":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/","name":"Continuing the Debate on Solar-driven Moisture - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"datePublished":"2013-09-02T12:30:07+00:00","dateModified":"2014-02-28T15:12:03+00:00","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/continuing-the-debate-on-solar-driven-moisture\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"Continuing the Debate on Solar-driven Moisture"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/27a8ccc930cede4eeb25c6a121d87bc5","name":"eyetee","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/350707945ce7247871e60b8a2dbdd6e9d782ad126bf26d9888c81624a6550167?s=96&d=mm&r=g","caption":"eyetee"},"url":"https:\/\/www.constructionspecifier.com\/author\/eyetee\/"}]}},"views":6411,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/406","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=406"}],"version-history":[{"count":20,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/406\/revisions"}],"predecessor-version":[{"id":477,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/406\/revisions\/477"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=406"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=406"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=406"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}