{"id":4204,"date":"2014-06-24T12:31:29","date_gmt":"2014-06-24T16:31:29","guid":{"rendered":"http:\/\/www.constructionspecifier.com\/?p=4204"},"modified":"2017-01-13T15:27:39","modified_gmt":"2017-01-13T20:27:39","slug":"design-of-fire-resistive-exposed-wood-members","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/","title":{"rendered":"Design of fire-resistive exposed wood members"},"content":{"rendered":"<figure id=\"attachment_4206\" aria-describedby=\"caption-attachment-4206\" style=\"width: 342px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-4206\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001-1000x670.jpg\" alt=\"Photo courtesy Structurlam\" width=\"342\" height=\"229\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001-1000x670.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001-300x201.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001-624x418.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001.jpg 2048w\" sizes=\"auto, (max-width: 342px) 100vw, 342px\" \/><\/a><figcaption id=\"caption-attachment-4206\" class=\"wp-caption-text\"><em>Photo courtesy Structurlam<\/em><\/figcaption><\/figure>\n<p><strong>by Bradford Douglas, PE, and Jason Smart, PE<br \/>\n<\/strong>Designing for life safety is complex and multifaceted, and fire-related issues comprise a large portion of model codes. For nearly 15 years, a mechanics-based design method has been used in the United States to estimate the capacity of exposed wood members using basic wood engineering mechanics.<\/p>\n<p>This mechanics-based design method first appeared in the 1999 version of Technical Report (TR) 10,<em> Calculating the Fire Resistance of Exposed Wood Members <\/em>(TR 10). This method was then incorporated into new design procedures of the 2001 <em>National Design Specification<\/em> (<em>NDS<\/em>) <em>for Wood Construction<\/em>. These procedures were later adopted into the model building codes through reference to the <em>NDS<\/em> for calculating fire resistance of wood members. The procedures have been used extensively for design of large, exposed wood members, but are now also beginning to be employed for estimating structural fire resistance of smaller exposed wood members.<\/p>\n<p><figure id=\"attachment_4210\" aria-describedby=\"caption-attachment-4210\" style=\"width: 670px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_6.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-4210\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_6-1000x331.jpg\" alt=\"Excerpt from Design for Code Acceptance (DCA) 2, Design of Fire-resistive Exposed Wood Members, Table 1 (one-hr). This shows tabulated one-hour design load ratios, Rs, for flexural members exposed on three sides. [CREDIT] Data courtesy American Wood Council \" width=\"670\" height=\"222\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_6-1000x331.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_6-300x99.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_6-624x206.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_6.jpg 2048w\" sizes=\"auto, (max-width: 670px) 100vw, 670px\" \/><\/a><figcaption id=\"caption-attachment-4210\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial,helvetica,sans-serif;\">Excerpt from Design for Code Acceptance (DCA) 2, <em>Design of Fire-resistive Exposed Wood Members<\/em>, Table 1 (one-hr). This shows tabulated one-hour design load ratios, Rs, for flexural members exposed on three sides.<\/span> <em>Data courtesy American Wood Council<\/em><\/figcaption><\/figure>Wood buildings can be designed to meet rigorous standards for performance, which is why the <em>International Building Code<\/em> (<em>IBC<\/em>) allows the material\u2019s use in a wide range of building types\u2014including structures that are taller and have more area than some designers realize. Table 601 of the <em>IBC<\/em> shows the required fire resistance of building elements (<em>i.e.<\/em> structural frame, walls, floors, and roofs) for each construction type. Ratings are given in hours. The exception is Type IV, where the wood structural elements are assumed to have inherent fire resistance due to their required minimum dimensions\u2014in other words, no fire resistance rating is necessary except for exterior walls.<\/p>\n<p>Fire resistance is a measure of the length of time an assembly or structural element can sustain a given load when subjected to a standardized fire exposure condition. Fire resistance of wood members and assemblies may be established by any one of five means listed in <em>IBC<\/em> Section 703.3, \u201cAlternative methods for determining fire resistance.\u201d The most common methods are tested assemblies and calculated fire resistance.<\/p>\n<figure id=\"attachment_4209\" aria-describedby=\"caption-attachment-4209\" style=\"width: 311px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-4209\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_5-1000x991.jpg\" alt=\"Excerpt from DCA 2, Table 2 (two-hr), showing tabulated two-hour design load ratios, Rs, for compression members exposed on four sides.\" width=\"311\" height=\"308\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_5-1000x991.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_5-150x150.jpg 150w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_5-300x297.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_5-50x50.jpg 50w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_5-624x618.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_5.jpg 2048w\" sizes=\"auto, (max-width: 311px) 100vw, 311px\" \/><\/a><figcaption id=\"caption-attachment-4209\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial,helvetica,sans-serif;\">Excerpt from DCA 2, Table 2 (two-hr), showing tabulated two-hour design load ratios, <em>Rs<\/em>, for compression members exposed on four sides.<\/span><\/figcaption><\/figure>\n<p><strong>Fire design of exposed wood members<\/strong><br \/>\nThe fire resistance of exposed wood members, including lumber, glued-laminated (glulam) timber, and structural composite lumber (SCL), may be calculated using provisions of <em>NDS<\/em>. This allowable stress design approach is referenced in <em>IBC<\/em> Section 722, \u201cCalculated Fire Resistance.\u201d The design procedure allows calculation of the capacity of exposed wood members using basic engineering mechanics.<\/p>\n<p>Actual mechanical and physical properties of the wood are used, with member capacity directly calculated for a given period\u2014up to two hours. Section properties are computed assuming an effective char rate (<em>i.e.<\/em> <em>?<sub>eff<\/sub><\/em>) at a given time (<em>i.e.<\/em> <em>t)<\/em>. Reductions of strength and stiffness of wood directly adjacent to the char layer are addressed by accelerating the char rate by 20 percent. Average member strength properties are approximated from existing accepted procedures used to calculate design properties. Finally, wood members are designed using accepted engineering procedures found in <em>NDS<\/em> for allowable stress design. (The design procedures presented in <em>NDS<\/em> Chapter 16 are not intended to be used for the design and retrofit of structures after a fire.)<\/p>\n<p>For sawn lumber, glulam, and SCL, the nominal char rate (<em>i.e.<\/em> <em>?<sub>n<\/sub>)<\/em> is typically assumed to be 38 mm\/hour (1.5 in.\/hour). For a given time in hours, the effective char rate is then:<\/p>\n<p><span style=\"font-size: 12pt; font-family: times new roman,times;\">?_(eff=) 1.8\/t^0.187 in.\/hour <\/span><\/p>\n<p>To calculate section properties of wood members, the effective char layer thickness (<em>i.e.<\/em> <em>a<sub>eff<\/sub>)<\/em>, for structural calculations is computed as:<\/p>\n<p><span style=\"font-size: 12pt; font-family: times new roman,times;\">a_(eff=) 1.8t^0.813 in. <\/span><\/p>\n<figure id=\"attachment_4213\" aria-describedby=\"caption-attachment-4213\" style=\"width: 205px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/DSCN0528.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-4213\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/DSCN0528-750x1000.jpg\" alt=\"This photo showcases glued-laminated lumber (glulam). Photos courtesy Structurlam \" width=\"205\" height=\"274\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/DSCN0528-750x1000.jpg 750w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/DSCN0528-225x300.jpg 225w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/DSCN0528-624x832.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/DSCN0528.jpg 1536w\" sizes=\"auto, (max-width: 205px) 100vw, 205px\" \/><\/a><figcaption id=\"caption-attachment-4213\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial,helvetica,sans-serif;\">This photo showcases glued-laminated lumber (glulam). <\/span><em>Photos courtesy Structurlam<\/em><\/figcaption><\/figure>\n<p>The 2012 and earlier versions of <em>IBC <\/em>have also contained an empirical calculation method for estimating the structural fire resistance of wood beams and columns exposed to a standard fire exposure for up to one hour. However, this empirical method has been removed from the 2015 <em>IBC<\/em> in favor of provisions contained within <em>NDS<\/em> Chapter 16 that are much broader in application and leave less room for design error.<\/p>\n<p><strong>Basis for <em>NDS<\/em> chapter 16 approach<\/strong><br \/>\nAWC\u2019s TR 10 contains full details of the <em>NDS<\/em> method as well as design examples.<sup>1<\/sup> TR 10 was recently revised to incorporate a new section that supports the use of the design method with smaller dimension sizes associated with lumber joist floor assemblies. It also has revised design examples to match the 2012 <em>NDS<\/em>.<\/p>\n<p>The revised design tables in Appendix A allow more accurate calculation of fire resistance of columns with any slenderness ratio. They also eliminate tabulation of special cases that can be misapplied, such as:<\/p>\n<ul>\n<li>deleted beams exposed on four sides that are assumed to be fully braced throughout the fire rating;<\/li>\n<li>columns only exposed on three sides, but assumed to be unbraced; and<\/li>\n<li>tension members that do not resist flexure due to member dead load.<\/li>\n<\/ul>\n<p>Finally, a new Appendix B that calculates the fire resistance of single-span lumber joists for any design stress ratio when joists are exposed on three sides and braced on the top edge was incorporated.<\/p>\n<p><strong>Simplified approach<\/strong><br \/>\nAWC\u2019s Design for Code Acceptance (DCA) 2,<em> Design of Fire-resistive Exposed Wood Members<\/em> has been revised to replace the empirical design equations currently in the 2012 <em>IBC<\/em> with simplified design information developed in accordance with the code-approved <em>NDS<\/em> fire design procedure for exposed wood members. The tables and examples have been rewritten for consistency with the approach outlined in the 2012 <em>NDS<\/em> and TR 10.<\/p>\n<figure id=\"attachment_4207\" aria-describedby=\"caption-attachment-4207\" style=\"width: 194px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-2011.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-4207\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-2011-666x1000.jpg\" alt=\"Supporting arches were used at the Boy Scouts of America Camp Fife project. \" width=\"194\" height=\"291\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-2011-666x1000.jpg 666w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-2011-199x300.jpg 199w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-2011-624x936.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-2011.jpg 1365w\" sizes=\"auto, (max-width: 194px) 100vw, 194px\" \/><\/a><figcaption id=\"caption-attachment-4207\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial,helvetica,sans-serif;\">Supporting arches were used at the Boy Scouts of America Camp Fife project<\/span>.<\/figcaption><\/figure>\n<p>For beams and columns stressed in one principal direction, simplifications can be made to allow creation of load ratio tables. These tables can then be used to determine the structural design load ratio at which the member has sufficient capacity for a given fire resistance time. Tables in DCA 2 give load ratios corresponding to one-hour, 1.5-hour, and two-hour fire resistance ratings for specified member dimensions.<\/p>\n<p>All tabulated load ratios apply to standard reference conditions where the load duration factor, wet service factor, and temperature factor equal 1.0 (C<sub>D<\/sub>=1.0; C<sub>M<\/sub>=1.0; C<sub>t<\/sub>=1.0). For more complex calculations where stress interactions must be considered, or where standard reference conditions do not apply, designers should use the provisions outlined in TR 10, along with the appropriate <em>NDS<\/em> provisions.<\/p>\n<p><strong>Flexural members<\/strong><br \/>\nDesign load ratios (<em>i.e.<\/em> <em>R<sub>s<\/sub><\/em>) for fire design of flexural members for various beam sizes are tabulated in DCA 2 tables for one-hour, 1.5-hour, and two-hour fire resistance ratings. The <em>R<sub>s<\/sub><\/em> values given in these tables apply to three-sided exposure in which the beam\u2019s top edge is protected from fire exposure (<em>e.g.<\/em> protected by the underside of a floor or roof). These tabulated values apply to flexural members loaded in bending about one axis only, and are continuously laterally supported along the compression edge. The dimension \u2018d\u2019 is the actual cross-sectional dimension measured in the direction normal to the axis about which bending occurs, and is not necessarily greater than \u2018b\u2019 (Figure 1).<\/p>\n<p>To use the DCA 2 tables, the designer only needs to know the required fire resistance rating (FRR), the structural load ratio (<em>R<sub>s<\/sub><\/em>), and the beam dimensions. For example, when a beam is exposed on three sides and is protected by a floor deck bracing the compression edge, it is required to have a one-hour FRR. When the design professional wants to use a 152.4 x 330.2-mm (6 \u00be x 13 \u00bd-in.) beam being loaded in bending about the strong axis, DCA 2 Table 1 (one-hour) shows a 152.4 x 330.2-mm beam would calculate to have a one-hour fire resistance rating if loaded to its full design load (<em>R<sub>s<\/sub><\/em>=1).<\/p>\n<figure id=\"attachment_4215\" aria-describedby=\"caption-attachment-4215\" style=\"width: 290px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-057.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-4215\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-057-1000x666.jpg\" alt=\"The entrance of the Rocky Mountain Elk Foundation building. [CREDIT] Photo courtesy Structurlam\/OZ Architects \" width=\"290\" height=\"193\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-057-1000x666.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-057-300x199.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-057-624x415.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-057.jpg 2048w\" sizes=\"auto, (max-width: 290px) 100vw, 290px\" \/><\/a><figcaption id=\"caption-attachment-4215\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial,helvetica,sans-serif;\">The entrance of the Rocky Mountain Elk Foundation building.<\/span> <em>Photos courtesy Structurlam\/OZ Architects<\/em><\/figcaption><\/figure>\n<figure id=\"attachment_4214\" aria-describedby=\"caption-attachment-4214\" style=\"width: 292px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-056.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-4214\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-056-1000x666.jpg\" alt=\"OZ Architects used structural composite lumber (SCL) for the Rocky Mountain Elk Foundation building in Missoula, Montana. \" width=\"292\" height=\"194\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-056-1000x666.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-056-300x199.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-056-624x415.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/RMEF-056.jpg 2048w\" sizes=\"auto, (max-width: 292px) 100vw, 292px\" \/><\/a><figcaption id=\"caption-attachment-4214\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial,helvetica,sans-serif;\">OZ Architects used structural composite lumber (SCL) for the Rocky Mountain Elk Foundation building in Missoula, Montana.<\/span><\/figcaption><\/figure>\n<p><strong>Compression members<\/strong><br \/>\nDesign load ratios, <em>R<sub>s<\/sub><\/em>, for fire design of columns are calculated as the product of two ratios, <em>R<sub>s1<\/sub><\/em> and <em>R<sub>s2<\/sub><\/em>. Values of <em>R<sub>s1<\/sub><\/em> and <em>R<sub>s2<\/sub><\/em> for various column sizes are tabulated in DCA 2 for one-hour, 1.5-hour, and two-hour fire resistance ratings. For cases in which the product of <em>R<sub>s1<\/sub><\/em> and <em>R<sub>s2<\/sub><\/em> is greater than 1.0, <em>R<sub>s<\/sub><\/em> should be taken as 1.0. These tables apply to cases in which all four sides are exposed to the fire; however, values calculated using these design load ratios may be conservatively applied when one or more sides of the column are protected. Both\u2018d\u2019 and \u2018b\u2019 represent the dry dressed cross-sectional column dimensions. The dimension \u2018d\u2019 is the actual dimension measured in the direction perpendicular to the axis about which buckling is being considered, and is not necessarily greater than \u2018b\u2019 (Figure 2). The designer should consider buckling about both axes and use the lesser design value.<\/p>\n<p>The tabulated <em>R<sub>s1<\/sub><\/em> values are calculated based on a square column cross-section having dimensions \u2018d\u2019 by \u2018d,\u2019 and therefore must be multiplied by <em>R<sub>s2<\/sub><\/em> for any column that is not square. Where \u2018b\u2019 is less than \u2018d,\u2019 <em>R<sub>s2<\/sub><\/em> will be less than 1.0; and where \u2018b\u2019 is greater than \u2018d,\u2019 <em>R<sub>s2<\/sub><\/em> will be greater than 1.0. The <em>R<sub>s1<\/sub><\/em> values are derived using the more conservative value of the parameter \u2018c\u2019 from equation 3.7-1 of the <em>NDS<\/em> (for long columns, c=0.9 results in lower <em>R<sub>s1<\/sub><\/em> values; for short columns, c=0.8 results in lower <em>R<sub>s1<\/sub><\/em> values). This allows the design load ratios to be used with sawn lumber, structural glulam, or SCL. The <em>R<sub>s1<\/sub><\/em> values are also based on the assumption that E<sub>min<\/sub>\u2019\/F<sub>c<\/sub>*= 350. As a result, the design load ratios (<em>R<sub>s<\/sub><\/em>) may conservatively be used for all species and grades where the ratio of E<sub>min<\/sub>\u2019 to F<sub>c<\/sub>* is greater than or equal to 350.<\/p>\n<p><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CS_July_2014_HR-54.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-4211\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CS_July_2014_HR-54.jpg\" alt=\"CS_July_2014.indd\" width=\"233\" height=\"265\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CS_July_2014_HR-54.jpg 450w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CS_July_2014_HR-54-263x300.jpg 263w\" sizes=\"auto, (max-width: 233px) 100vw, 233px\" \/><\/a>To use the tables, the designer only needs to know:<\/p>\n<ul>\n<li>required fire resistance rating;<\/li>\n<li>structural load ratio;<\/li>\n<li>column dimensions;<\/li>\n<li>unbraced length of the column; and<\/li>\n<li>end support conditions.<\/li>\n<\/ul>\n<p>For example, in a case where an exposed column is required to have a two-hour FRR, the designer may want to use a nominal 14&#215;16 column with actual dry dimensions of 330 x 381 mm (13 \u00bc x 15 in.). The column will have an unbraced length of 3.35 m (11 ft) in both directions, and can conservatively be assumed to have pinned end conditions on each end of the column (K<sub>e<\/sub>=1.0).<\/p>\n<p>Since the unbraced length is the same in both directions, buckling would tend to be about the 13\u00bc-in. dimension. The effective length (<em>i.e.<\/em> <em>L<sub>e<\/sub>)<\/em> would be 3352 mm (132 in.) and the L<sub>e<\/sub>\/d ratio would be 10. From DCA 2 Table 2 (two-hour), a square column that is 13\u00bc x 13\u00bc in. with L<sub>e<\/sub>\/d=10 would have an R<sub>s1<\/sub>=0.39. A 13\u00bc x 15-in. column buckling about the 13\u00bc in. dimension would have an <em>R<sub>s2<\/sub><\/em>=1.11. Therefore, the 13\u00bc x 15-in. column would calculate to have a two-hour fire resistance rating when loaded to 43 percent or less of its full design load (<em>R<sub>s<\/sub><\/em> = [<em>R<sub>s1<\/sub><\/em>][<em>R<sub>s2<\/sub><\/em>] = [0.39][1.11] = 0.43).<\/p>\n<p><strong>Timber decking<\/strong><br \/>\nDCA 2 also provides tabulated design load ratios (<em>R<sub>s<\/sub><\/em>) for various decking types and thicknesses, corresponding to one-hour, 1.5-hour, and two-hour fire resistance ratings. The dimensions \u2018b\u2019 and \u2018d\u2019 given in these tables are the actual dry dressed dimensions of each individual member. The <em>R<sub>s<\/sub><\/em> values given in DCA 2 Table 3.1 are applicable to butt-joint timber decking fully exposed on one face and partially exposed on the sides, in accordance with <em>NDS<\/em> Section 16.2.5.<\/p>\n<p>The <em>R<sub>s<\/sub><\/em>values given in DCA 2 Table 3.2 are applicable to double and single tongue-and-groove decking exposed only on one face. These calculation procedures do not address thermal separation.<\/p>\n<p><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-4208\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_3-916x1000.jpg\" alt=\"Constr-Specfr-Douglas-Smart-Fire-140506_Page_3\" width=\"267\" height=\"292\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_3-916x1000.jpg 916w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_3-275x300.jpg 275w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_3-624x680.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/Constr-Specfr-Douglas-Smart-Fire-140506_Page_3.jpg 1878w\" sizes=\"auto, (max-width: 267px) 100vw, 267px\" \/><\/a>To use the tables, the designer only needs to know the required fire-resistance rating, the structural load ratio (<em>R<sub>s<\/sub><\/em>) and the decking type and dimensions. For example, a timber deck is required to have a 1.5-hour FRR, and the designer wants to use 4x tongue-and-groove decking. From DCA 2 Table 3.2, the nominal 4x tongue and groove decking (76.2 mm [3\u00bd in.] actual thickness) would calculate to have a 1.5-hour fire resistance rating if loaded to 23 percent or less of its full design load (<em>R<sub>s<\/sub><\/em>=0.23).<\/p>\n<p><em>Connections<\/em><br \/>\nWhere a specified fire resistance rating is required, Section 16.3 of the <em>NDS <\/em>requires connectors and fasteners be protected from fire exposure. This protection can be achieved by any of the following:<\/p>\n<ul>\n<li>wood members having dimensions sufficient to prevent the char front from reaching the connectors and fasteners for the duration of the required fire-resistance rating time\u2014the char front can be calculated as: a=1.5t^0.813 in.;<\/li>\n<li>fire-rated gypsum board having a finish rating greater than or equal to the required fire-resistance rating; and<\/li>\n<li>any approved coating having a fire rating greater than or equal to the required fire resistance rating time.<\/li>\n<\/ul>\n<p><strong>Conclusion<\/strong><br \/>\nStructural fire design provisions have been incorporated in Chapter 16 of <em>NDS<\/em>, which is referenced in Section 722.1 of the 2012 <em>IBC<\/em> as a method of calculating fire resistance of exposed wood members. A comprehensive discussion of this mechanics-based design procedure can be found in <em>Technical Report No. 10<\/em>, while DCA 2 provides a simplified design aid of this code-approved fire design procedure for several typical applications with exposed wood members. <sup>2<\/sup><\/p>\n<p><strong>Notes<\/strong><br \/>\n<sup>1<\/sup> For more information, TR 10,<em> Calculating the Fire Resistance of Exposed Wood Members<\/em>, is available at<a href=\"http:\/\/www.awc.org\/pdf\/TR10.pdf\"> www.awc.org\/pdf\/TR10.pdf<\/a>.<br \/>\n<sup>2<\/sup> Additional information on building code requirements for wood can be found in the American Wood Council\u2019s <em>Code Conforming Wood Design<\/em> documents, available at <a href=\"http:\/\/www.awc.org\/codes\/ccwdindex.php\">www.awc.org\/codes\/ccwdindex.php<\/a>.<\/p>\n<p><em>Brad Douglas, PE, joined the American Wood Council (AWC) in 1986, and serves as its vice president of engineering. Douglas directs a program aimed at developing state-of-the-art engineering data, technology, and standards on structural wood products, systems, and assemblies for use by design professionals and building officials to assure safe and efficient design and use of wood. He is a graduate of Virginia Tech. Douglas can be contacted at <a href=\"mailto:%20bdouglas@awc.org\">bdouglas@awc.org<\/a>.<\/em><\/p>\n<p><em>Jason Smart, PE, joined AWC in 2013 and is manager of engineering technology. Smart focuses on development and support for new and emerging technologies and related changes to design and model building code standards. He is a graduate of Virginia Tech with degrees in civil engineering, wood science and forest products, and timber engineering. He can be reached at <a href=\"mailto:%20jsmart@awc.org\">jsmart@awc.org<\/a>.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The article offers an in-depth look at design considerations for fire resistance when building with wood products. It also looks at wood engineering mechanics and design procedures that comply with the <em>International Building Code<\/em> (<em>IBC<\/em>), recognizing fire resistance demonstrated by structural wood beams and columns in actual fires.<\/p>\n","protected":false},"author":4,"featured_media":4206,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,179,449,186,256,261,459],"tags":[997,594,998,60,694,999,20],"class_list":["post-4204","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-masterformat","category-uniformat","category-06-00-00-wood-plastics-and-composites","category-06-10-00-rough-carpentry","category-06-70-00-structural-composites","category-b10superstructure","tag-06-12-00-structural-panels","tag-06-18-00-glued-laminated-construction","tag-06-71-13-composite-lumber","tag-fire","tag-international-building-code","tag-national-design-specification-nds-for-wood-construction","tag-wood","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Design of fire-resistive exposed wood members - The Construction Specifier<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Design of fire-resistive exposed wood members - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"The article offers an in-depth look at design considerations for fire resistance when building with wood products. It also looks at wood engineering mechanics and design procedures that comply with the International Building Code (IBC), recognizing fire resistance demonstrated by structural wood beams and columns in actual fires.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2014-06-24T16:31:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-01-13T20:27:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2048\" \/>\n\t<meta property=\"og:image:height\" content=\"1373\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Molly Doyle\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Molly Doyle\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/\"},\"author\":{\"name\":\"Molly Doyle\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/2fe1805293ddcc967e4bd9e8afc50294\"},\"headline\":\"Design of fire-resistive exposed wood members\",\"datePublished\":\"2014-06-24T16:31:29+00:00\",\"dateModified\":\"2017-01-13T20:27:39+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/\"},\"wordCount\":2383,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2014\\\/06\\\/CF-001.jpg\",\"keywords\":[\"06 12 00\u2013Structural Panels\",\"06 18 00\u2013Glued-Laminated Construction\",\"06 71 13\u2013Composite Lumber\",\"fire\",\"International Building Code\",\"National Design Specification (NDS) for Wood Construction\",\"Wood\"],\"articleSection\":[\"Features\",\"MasterFormat\",\"UniFormat\",\"06 00 00 Wood, Plastics, and Composites\",\"06 10 00 Rough Carpentry\",\"06 70 00 Structural Composites\",\"B10\u2212Superstructure\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/\",\"name\":\"Design of fire-resistive exposed wood members - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2014\\\/06\\\/CF-001.jpg\",\"datePublished\":\"2014-06-24T16:31:29+00:00\",\"dateModified\":\"2017-01-13T20:27:39+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2014\\\/06\\\/CF-001.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2014\\\/06\\\/CF-001.jpg\",\"width\":2048,\"height\":1373,\"caption\":\"Photo courtesy Structurlam\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/design-of-fire-resistive-exposed-wood-members\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Design of fire-resistive exposed wood members\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/2fe1805293ddcc967e4bd9e8afc50294\",\"name\":\"Molly Doyle\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b9db24e2e72277a0449a8b18be06d377923ec2d6246b36613db304f58b586baf?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b9db24e2e72277a0449a8b18be06d377923ec2d6246b36613db304f58b586baf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b9db24e2e72277a0449a8b18be06d377923ec2d6246b36613db304f58b586baf?s=96&d=mm&r=g\",\"caption\":\"Molly Doyle\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/molly\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Design of fire-resistive exposed wood members - The Construction Specifier","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/","og_locale":"en_US","og_type":"article","og_title":"Design of fire-resistive exposed wood members - The Construction Specifier","og_description":"The article offers an in-depth look at design considerations for fire resistance when building with wood products. It also looks at wood engineering mechanics and design procedures that comply with the International Building Code (IBC), recognizing fire resistance demonstrated by structural wood beams and columns in actual fires.","og_url":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/","og_site_name":"The Construction Specifier","article_published_time":"2014-06-24T16:31:29+00:00","article_modified_time":"2017-01-13T20:27:39+00:00","og_image":[{"width":2048,"height":1373,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001.jpg","type":"image\/jpeg"}],"author":"Molly Doyle","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Molly Doyle","Est. reading time":"12 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/"},"author":{"name":"Molly Doyle","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/2fe1805293ddcc967e4bd9e8afc50294"},"headline":"Design of fire-resistive exposed wood members","datePublished":"2014-06-24T16:31:29+00:00","dateModified":"2017-01-13T20:27:39+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/"},"wordCount":2383,"commentCount":1,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001.jpg","keywords":["06 12 00\u2013Structural Panels","06 18 00\u2013Glued-Laminated Construction","06 71 13\u2013Composite Lumber","fire","International Building Code","National Design Specification (NDS) for Wood Construction","Wood"],"articleSection":["Features","MasterFormat","UniFormat","06 00 00 Wood, Plastics, and Composites","06 10 00 Rough Carpentry","06 70 00 Structural Composites","B10\u2212Superstructure"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/","url":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/","name":"Design of fire-resistive exposed wood members - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001.jpg","datePublished":"2014-06-24T16:31:29+00:00","dateModified":"2017-01-13T20:27:39+00:00","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/06\/CF-001.jpg","width":2048,"height":1373,"caption":"Photo courtesy Structurlam"},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/design-of-fire-resistive-exposed-wood-members\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"Design of fire-resistive exposed wood members"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/2fe1805293ddcc967e4bd9e8afc50294","name":"Molly Doyle","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/b9db24e2e72277a0449a8b18be06d377923ec2d6246b36613db304f58b586baf?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b9db24e2e72277a0449a8b18be06d377923ec2d6246b36613db304f58b586baf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b9db24e2e72277a0449a8b18be06d377923ec2d6246b36613db304f58b586baf?s=96&d=mm&r=g","caption":"Molly Doyle"},"url":"https:\/\/www.constructionspecifier.com\/author\/molly\/"}]}},"views":21555,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/4204","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=4204"}],"version-history":[{"count":10,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/4204\/revisions"}],"predecessor-version":[{"id":25036,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/4204\/revisions\/25036"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/4206"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=4204"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=4204"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=4204"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}