{"id":5876,"date":"2014-11-07T08:54:18","date_gmt":"2014-11-07T13:54:18","guid":{"rendered":"http:\/\/www.constructionspecifier.com\/?p=5876"},"modified":"2017-01-31T12:07:46","modified_gmt":"2017-01-31T17:07:46","slug":"dutch-students-redevelop-the-traditional-rowhouse","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/","title":{"rendered":"Dutch students redevelop the traditional rowhouse"},"content":{"rendered":"<figure id=\"attachment_5877\" aria-describedby=\"caption-attachment-5877\" style=\"width: 1156px\" class=\"wp-caption alignleft\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5877 size-full\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781.jpg\" alt=\"Photo courtesy Pr\u00eat-\u00e0-Loger\" width=\"1156\" height=\"635\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781.jpg 1156w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781-300x165.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781-1000x549.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781-624x343.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781-768x422.jpg 768w\" sizes=\"auto, (max-width: 1156px) 100vw, 1156px\" \/><figcaption id=\"caption-attachment-5877\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">Delft University of Technology (TU Delft) students earned third place at the Solar Decathlon Europe 2014 for the Pr\u00eat-\u00e0-Loger project, which shows how the sustainability of existing rowhouses can be improved.<\/span> <em>Photo courtesy Pr\u00eat-\u00e0-Loger<\/em><\/figcaption><\/figure>\n<p><strong>by Jacquie Clancy<br \/>\n<\/strong>A new Dutch rowhouse design incorporating solar energy and year-round green space could also have uses in the United States. Students from the Delft University of Technology (TU Delft) in the Netherlands earned an overall third-place finish at the Solar Decathlon Europe 2014 for their <a href=\"http:\/\/www.pretaloger.nl\" target=\"_blank\">Pr\u00eat-\u00e0-Loger<\/a> (<em>i.e.<\/em> Home with a Skin) project, which demonstrates how sustainability on existing European rowhouses can be improved.<\/p>\n<p>The Solar Decathlon program challenges university student teams to create residences powered by solar energy. This year\u2019s installment took place in Versailles, France, where projects were evaluated by a jury panel of industry experts in 10 categories.<\/p>\n<p>The Pr\u00eat-\u00e0-Loger project originated with a 1960s rowhouse in the South Holland town, Honselersdijk. The goal was to increase the energy efficiency of the \u2018house,\u2019 while also preserving the \u2018home\u2019 for its occupants. In other words, the physical structure was revamped to decrease its environmental impact, while the personal aspects were maintained. The solution was to apply an adaptable glass structure, or \u2018second skin,\u2019 to the house, allowing it to be exclusively powered by solar energy, while also permitting the garden space to be used year-round.<\/p>\n<p>In terms of the second skin, the project team determined spatial connection, climate performance, and applicability as the main criteria for the glass structure. The transition area between the indoor space and the outdoor space housed within the glass structure needed to remain clear. In order to add to the existing living space, the structure must also be adaptable for all seasons. Finally, the construction must cause minimal occupant disruptions.<\/p>\n<p>An additional layer of insulation was added to the existing structure on the northwest (or \u2018cold\u2019) side of the house. The \u2018warm\u2019 southeast side is where the glass structure housing the garden area is located. For many Dutch households, the garden is an important element of the home. With the installation of a second skin on the house, the temperatures can still remain conducive to gardening, while the living space of the home remains heated during the winter. Once the weather is warm, the outdoor garden area within the glass structure\u2019s functioning doors can be used as an extension on the home\u2019s living space, while also providing natural ventilation. A fan and heat-exchanger are located within the transitional area so occupants can adjust the temperature as necessary.<\/p>\n<figure id=\"attachment_5878\" aria-describedby=\"caption-attachment-5878\" style=\"width: 300px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5878 size-medium\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/007-300x225.jpg\" alt=\"A building-integrated photovoltaic (BIPV) system was employed with PV panels installed on the aluminum frame system of the glass structure to generate energy for the house.\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/007-300x225.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/007-1000x750.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/007-624x468.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/007.jpg 2048w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-5878\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">A building-integrated photovoltaic (BIPV) system was employed with PV panels installed on the aluminum frame system of the glass structure to generate energy for the house.<\/span><\/figcaption><\/figure>\n<p>TU Delft\u2019s Architectural Engineering and Technology department head, Andy van den Dobbelsteen, is the primary faculty advisor for the project, and explains the skin\u2019s climate\/energy concept is a highlight of the house.<\/p>\n<p>\u201cWe consider the innovative climate\/energy concept of the skin\u2014particularly the greenhouse and its functions, but also the invisible solutions in the \u2018underground skin\u2019\u2014a highlight,\u201d he explained to <em>The Construction Specifie<\/em>r. \u201cThe project is not just an energy story; its mainly about improving the lives of people. With our concept, homeowners see their energy-consuming, humid, mouldy, cold house turned into something comfortable and liveable, without extra energy costs but with extra space.\u201d<\/p>\n<p>Due to the materials used to create the glass house, poor acoustics was a concern for the design team. To improve the space\u2019s acoustic comfort, the team added wood floors, additional vegetation and plants on the walls, and fabric shading panels. Another acoustic concern was due to the placement of the HVAC system equipment. In the original rowhouse design, the HVAC would have been installed in the attic. However, as part of the Solar Decathlon Europe 2014 competition\u2019s solar envelope requirements, the attic was removed from the house\u2019s design. Therefore, the mechanical system was placed against the exterior wall in the first-floor bedroom.<\/p>\n<p>A building-integrated photovoltaic (BIPV) system was employed with PV panels installed on the aluminum frame system of the glass structure. This is supported by a light steel skeleton with a system of main and secondary beams, and a portal frame in its fa\u00e7ade. The main beams follow the 1.2-m (4-ft) grid pattern of the original rowhouse. To distribute the load of the second skin, it is attached to the house on the upper side, and on surface foundations at its base. The portal frame acts as a transfer point for the roof load, as well as a structural beam able to support the glass skin\u2019s door. Additional PV panels are also installed here. A small motor controls the glazed structure\u2019s door opening and closing, as well as the shading system on the exterior.<\/p>\n<p>In addition to the solar panels, the house\u2019s lighting design maximizes daylighting to decrease its electrical load. Along with the glazing on the exterior of the structure, tubular daylighting devices (TDDs) are employed in the main living space, providing sunlight through the roof.<\/p>\n<figure id=\"attachment_5879\" aria-describedby=\"caption-attachment-5879\" style=\"width: 321px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC09090.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5879\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC09090-1000x665.jpg\" alt=\"The house\u2019s \u2018second skin\u2019 allows the garden space to function all year. Photo courtesy Pr\u00eat-\u00e0-Loger \" width=\"321\" height=\"213\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC09090-1000x665.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC09090-300x199.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC09090-624x415.jpg 624w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC09090.jpg 1024w\" sizes=\"auto, (max-width: 321px) 100vw, 321px\" \/><\/a><figcaption id=\"caption-attachment-5879\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">The house\u2019s \u2018second skin\u2019 allows the garden space to function all year.<br \/><\/span> <em>Photo courtesy Pr\u00eat-\u00e0-Loger<\/em><\/figcaption><\/figure>\n<p>All interior lights are solid-state light-emitting diodes (LEDs) fitted with radio frequency (RF) adapters. This means the lights are turned on and off through wireless signals, rather than a wired electrical connection. This reduces the amount of cables required, and cuts down on installation time.<\/p>\n<p>The home\u2019s plumbing system was updated to allow for both fresh water and wastewater tanks. A water recovery system collects rainwater for non-potable uses inside the home. A heat-recovery system was also included, and a solar water-heating system operates with two panels using heat from the glass structure and transporting it to heat pumps.<\/p>\n<p>The Pr\u00eat-\u00e0-Loger project focuses on sustainability and minimizing environmental impact by reusing materials, optimizing energy performance, and extending the lifecycle of the common rowhouse. Prefabricated materials were specified for the project, as well as insulation and the passive second skin assembly that contribute to the goal of energy neutrality.<\/p>\n<p>As of now, the house remains on the university\u2019s campus and welcomes tours, demonstrations, exhibitions, education, and research testing. Dobbelsteen explains the same basic approach can be used to make U.S.\u00a0residences more efficient.<\/p>\n<p>\u201cFirst, look at housing typologies that are most dominant on the market, or that have the greatest improvement potential,\u201d he said. \u201cNext is the approach I teach students\u2014smart and bioclimatic design. This comes down to making optimal use of local circumstances, first by means of passive design principles, then improved by smart technology. However, the local features must be understood well before interventions are proposed.\u201d<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Students from the Delft University of Technology (TU Delft) in the Netherlands earned an overall third-place finish at the Solar Decathlon Europe 2014 for their Pr\u00eat-\u00e0-Loger (<em>i.e.<\/em> project, which demonstrates how sustainability on existing European rowhouses can be improved.<\/p>\n","protected":false},"author":2,"featured_media":5877,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[4,179,449,213,489,460,495,461,474],"tags":[3108,3109,601],"class_list":["post-5876","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-form-and-function","category-masterformat","category-uniformat","category-48-00-00-electrical-power-generation","category-b2010exterior-walls","category-b20exterior-vertical-enclosures","category-b3010roofing","category-b30exterior-horizontal-enclosures","category-f10special-construction","tag-solar-decathalon-europe-2014","tag-students","tag-sustainability","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Dutch students redevelop the traditional rowhouse - The Construction Specifier<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Dutch students redevelop the traditional rowhouse - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Students from the Delft University of Technology (TU Delft) in the Netherlands earned an overall third-place finish at the Solar Decathlon Europe 2014 for their Pr\u00eat-\u00e0-Loger (i.e. project, which demonstrates how sustainability on existing European rowhouses can be improved.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2014-11-07T13:54:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-01-31T17:07:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1156\" \/>\n\t<meta property=\"og:image:height\" content=\"635\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"CS Editor\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"CS Editor\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/\"},\"author\":{\"name\":\"CS Editor\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/68a0367dbed338beeaee76fa966e23ae\"},\"headline\":\"Dutch students redevelop the traditional rowhouse\",\"datePublished\":\"2014-11-07T13:54:18+00:00\",\"dateModified\":\"2017-01-31T17:07:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/\"},\"wordCount\":1147,\"commentCount\":6,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2014\\\/11\\\/DSC02186-e1475679844781.jpg\",\"keywords\":[\"Solar Decathalon Europe 2014\",\"Students\",\"Sustainability\"],\"articleSection\":[\"Form+Function\",\"MasterFormat\",\"UniFormat\",\"48 00 00 Electrical Power Generation\",\"B2010\u2212Exterior Walls\",\"B20\u2212Exterior Vertical Enclosures\",\"B3010\u2212Roofing\",\"B30\u2212Exterior Horizontal Enclosures\",\"F10\u2212Special Construction\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/\",\"name\":\"Dutch students redevelop the traditional rowhouse - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2014\\\/11\\\/DSC02186-e1475679844781.jpg\",\"datePublished\":\"2014-11-07T13:54:18+00:00\",\"dateModified\":\"2017-01-31T17:07:46+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2014\\\/11\\\/DSC02186-e1475679844781.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2014\\\/11\\\/DSC02186-e1475679844781.jpg\",\"width\":1156,\"height\":635,\"caption\":\"Photo courtesy Pr\u00eat-\u00e0-Loger\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/dutch-students-redevelop-the-traditional-rowhouse\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Dutch students redevelop the traditional rowhouse\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/68a0367dbed338beeaee76fa966e23ae\",\"name\":\"CS Editor\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e1b568804c00a30b9d7d83bf51348f54e159a9d813a141b0ac34df4e929de81e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e1b568804c00a30b9d7d83bf51348f54e159a9d813a141b0ac34df4e929de81e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e1b568804c00a30b9d7d83bf51348f54e159a9d813a141b0ac34df4e929de81e?s=96&d=mm&r=g\",\"caption\":\"CS Editor\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/editor\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Dutch students redevelop the traditional rowhouse - The Construction Specifier","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/","og_locale":"en_US","og_type":"article","og_title":"Dutch students redevelop the traditional rowhouse - The Construction Specifier","og_description":"Students from the Delft University of Technology (TU Delft) in the Netherlands earned an overall third-place finish at the Solar Decathlon Europe 2014 for their Pr\u00eat-\u00e0-Loger (i.e. project, which demonstrates how sustainability on existing European rowhouses can be improved.","og_url":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/","og_site_name":"The Construction Specifier","article_published_time":"2014-11-07T13:54:18+00:00","article_modified_time":"2017-01-31T17:07:46+00:00","og_image":[{"width":1156,"height":635,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781.jpg","type":"image\/jpeg"}],"author":"CS Editor","twitter_card":"summary_large_image","twitter_misc":{"Written by":"CS Editor","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/"},"author":{"name":"CS Editor","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/68a0367dbed338beeaee76fa966e23ae"},"headline":"Dutch students redevelop the traditional rowhouse","datePublished":"2014-11-07T13:54:18+00:00","dateModified":"2017-01-31T17:07:46+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/"},"wordCount":1147,"commentCount":6,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781.jpg","keywords":["Solar Decathalon Europe 2014","Students","Sustainability"],"articleSection":["Form+Function","MasterFormat","UniFormat","48 00 00 Electrical Power Generation","B2010\u2212Exterior Walls","B20\u2212Exterior Vertical Enclosures","B3010\u2212Roofing","B30\u2212Exterior Horizontal Enclosures","F10\u2212Special Construction"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/","url":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/","name":"Dutch students redevelop the traditional rowhouse - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781.jpg","datePublished":"2014-11-07T13:54:18+00:00","dateModified":"2017-01-31T17:07:46+00:00","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2014\/11\/DSC02186-e1475679844781.jpg","width":1156,"height":635,"caption":"Photo courtesy Pr\u00eat-\u00e0-Loger"},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/dutch-students-redevelop-the-traditional-rowhouse\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"Dutch students redevelop the traditional rowhouse"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/68a0367dbed338beeaee76fa966e23ae","name":"CS Editor","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/e1b568804c00a30b9d7d83bf51348f54e159a9d813a141b0ac34df4e929de81e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e1b568804c00a30b9d7d83bf51348f54e159a9d813a141b0ac34df4e929de81e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e1b568804c00a30b9d7d83bf51348f54e159a9d813a141b0ac34df4e929de81e?s=96&d=mm&r=g","caption":"CS Editor"},"url":"https:\/\/www.constructionspecifier.com\/author\/editor\/"}]}},"views":6264,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/5876","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=5876"}],"version-history":[{"count":11,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/5876\/revisions"}],"predecessor-version":[{"id":22787,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/5876\/revisions\/22787"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/5877"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=5876"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=5876"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=5876"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}