{"id":74809,"date":"2018-11-07T16:33:21","date_gmt":"2018-11-07T21:33:21","guid":{"rendered":"https:\/\/www.constructionspecifier.com\/?p=74809"},"modified":"2018-11-07T16:36:28","modified_gmt":"2018-11-07T21:36:28","slug":"cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/","title":{"rendered":"Cracking the code: Understanding the latest IBC revisions for builders hardware"},"content":{"rendered":"<p><strong>by John Woestman<\/strong><\/p>\n<figure id=\"attachment_74814\" aria-describedby=\"caption-attachment-74814\" style=\"width: 330px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-30-PM.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-74814\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-30-PM.jpg\" alt=\"\" width=\"330\" height=\"221\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-30-PM.jpg 1024w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-30-PM-300x201.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-30-PM-768x514.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-30-PM-500x334.jpg 500w\" sizes=\"auto, (max-width: 330px) 100vw, 330px\" \/><\/a><figcaption id=\"caption-attachment-74814\" class=\"wp-caption-text\"><em><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">Photo courtesy Bigstockphoto.com<\/span><\/em><\/figcaption><\/figure>\n<p>Door hardware standards play a significant role in life safety by ensuring products used in commercial and residential buildings are suitable for their intended use. These standards serve as tools for hardware manufacturers and building professionals by providing them with a mutual understanding of door hardware requirements and types of locking systems.<\/p>\n<p>The <em>International Building Code <\/em>(<em>IBC<\/em>) and the <em>International Fire Code<\/em> (<em>IFC<\/em>) are model regulations stipulating performance requirements for builders hardware\u2014such as door locks, door closers, and door exit devices (<em>i.e.<\/em> panic hardware)\u2014to ensure public safety and welfare. These model building, fire, and life safety regulations incorporate by reference product-specific consensus standards specifying a baseline level of performance, durability, and safety requirements for building materials and components. States, counties, and cities, when developing or updating their building and fire codes, usually adopt one or several of the model codes in conjuction with jurisdiction-specific modifications to the model code language and requirements.<\/p>\n<p>Standards\u2014such as those for builders hardware\u2014play \u2028an integral role in building codes by identifying minimum performance requirements for products or materials used in building construction. Like building codes, standards are developed by researching how products, materials, or structures have responded in the past to various conditions as well as weather and geological hazards. By packaging the complexity of numerous standards into a single document, building codes make it quicker and easier for officials to assess whether \u2028a building meets the necessary requirements for it to be considered \u201cup to code.\u201d<\/p>\n<p><strong>Setting a standard for safety<br \/>\n<\/strong>One priority of <em>IBC<\/em> is to make sure there are paths of egress at all times for building occupants. Doors within the path of egress, and how doors are required or permitted to function, have significant implications for safe egress. Over the years, <em>IBC <\/em>has evolved significantly. Some recent changes relate to the language used with reference to door hardware and emergency egress.<\/p>\n<p>One organization that has served as a subject matter expert for revisions to <em>IBC<\/em> is the Builders Hardware Manufacturers Association (BHMA). BHMA is the only organization accredited by the American National Standards Institute (ANSI) to develop and maintain performance standards for door locks, door closers, door exit devices, and other builders hardware. BHMA has been significantly involved in <em>IBC<\/em> change proposals, providing language and guidance on safe egress systems as it relates to builders hardware.<\/p>\n<p>Like building codes, builders hardware standards must be developed by consensus and reviewed every few years. These consensus standards are also approved by ANSI. The ANSI\/BHMA A156 Standards Series currently includes 41 standards, a number that keeps growing as new and emerging technologies continue to enter the door hardware space.<\/p>\n<p><strong>Building code updates<br \/>\n<\/strong>Some of the most recent <em>IBC<\/em> language updates, particularly as they relate to door hardware, include revisions to the descriptive names of the special locking systems to better describe the required functions of each system. These revisions are a result of the desire by door hardware manufacturers, specifiers, and security integrators to more accurately describe the function of the special locking systems, and to expand where these locking systems are permitted to be installed by <em>IBC<\/em>. BHMA worked closely with many stakeholders to ensure the revised <em>IBC<\/em> language was appropriate. The requirements for each of these special locking systems was refined to be more clear and concise, and to be more consistently interpreted, applied, and enforced.<\/p>\n<p><em>\u201cSpecial locking arrangements\u201d revised to \u201ccontrolled egress doors\u201d<br \/>\n<\/em>When referring to <em>IBC<\/em>, building professionals and code officials now find \u201cspecial locking arrangements\u201d for Groups I-1 and I-2 has been changed to \u201ccontrolled egress doors,\u201d to clarify a controlled egress door is locked to prevent egress, and egress is controlled by someone else. These door locking systems are permitted only in healthcare facilities where the clinical needs of the patient require this functionality, such as newborn nurseries and some assisted living facilities.<\/p>\n<p><em>\u201cDelayed egress locks\u201d revised to \u201cdelayed egress locking systems\u201d<br \/>\n<\/em>Changing \u201cdelayed egress locks\u201d to \u201cdelayed egress locking systems\u201d emphasizes there is an entire system behind the delayed egress lock, to allow for the safe egress of building occupants in the event of an emergency. Delayed egress locking systems function as the name implies\u2014they facilitate egress but with \u2028a relatively brief delay (15 to 30 seconds). These systems are designed so that when the fire protection system activates, the delay of the delayed egress locking system is automatically eliminated, allowing the door to remain locked mechanically and electrically preventing ingress, while providing immediate and free egress.<\/p>\n<p><em>\u201cAccess-controlled egress doors\u201d to \u201csensor release of electrically locked egress doors\u201d<br \/>\n<\/em>The term \u201caccess-controlled egress doors\u201d referred to electronic locking systems designed to prevent building access (ingress), while allowing egress by unlocking the door when a sensor on the egress side of the door detects movement. In other words, while the door(s) remains locked at all times, when the interior sensor detects a person approaching the door, the electrical locking system automatically unlocks the door(s) allowing immediate and free egress. However, since nearly all locking systems\u2014electrical and mechanical\u2014control access to a building, the older term \u201caccess-controlled egress doors\u201d had a wide variety of interpretations and applications, and enforcement varied significantly due to ambiguity. By changing the language to \u201csensor release of electrically locked egress doors\u201d the ambiguity surrounding this particular locking system will be reduced and a more uniform understanding of its applications will occur.<\/p>\n<p><em>\u201cElectromagnetically locked egress doors\u201d revised to \u201cdoor hardware release of electrically locked egress doors\u201d<br \/>\n<\/em>Originally, any reference to \u201celectromagnetically locked egress doors\u201d was for door locking systems in which the door-mounted hardware triggers the release of the door\u2019s electromagnetic lock. For clarity, this language was revised to \u201cdoor hardware release of electrically locked egress doors\u201d to emphasize exactly how this type of locking system is released, and to allow electrical locks that function by means other than electromagnetically. Additionally, since electromagnetic locks are commonly used in all of the locking systems mentioned, this revision addressed a misperception that any door locking system with an electromagnetic lock would be required to comply with the requirements for electromagnetic locks.<\/p>\n<figure id=\"attachment_74812\" aria-describedby=\"caption-attachment-74812\" style=\"width: 311px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/bigstock-Group-of-school-kids-running-a-252438082.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-74812\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/bigstock-Group-of-school-kids-running-a-252438082.jpg\" alt=\"\" width=\"311\" height=\"207\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/bigstock-Group-of-school-kids-running-a-252438082.jpg 1024w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/bigstock-Group-of-school-kids-running-a-252438082-300x200.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/bigstock-Group-of-school-kids-running-a-252438082-768x512.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/bigstock-Group-of-school-kids-running-a-252438082-500x333.jpg 500w\" sizes=\"auto, (max-width: 311px) 100vw, 311px\" \/><\/a><figcaption id=\"caption-attachment-74812\" class=\"wp-caption-text\">Delayed egress locking systems may be used in schools and childcare centers to prevent abductions or delinquency.<br \/><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><em>Photo courtesy Bigstockphoto.com<\/em><\/span><\/figcaption><\/figure>\n<p><strong>Code proposals<br \/>\n<\/strong><\/p>\n<p>With the 2021 <em>IBC<\/em> code development cycle currently in progress, BHMA continues to be actively involved in the process. In this development cycle, BHMA has proposed several revisions to the 2021 <em>IBC<\/em> intended to improve life safety.<\/p>\n<p><em>ANSI\/BHMA A156.24, Delayed Egress Locks<br \/>\n<\/em>Contrary to door locking systems providing immediate egress, delayed egresslocking systems prevent a door from opening immediately when egress is attempted in a non-emergency situation. ANSI\/BHMA A156.24, <em>Delayed Egress <\/em><em>Locks<\/em>, covers products used in connection with conventional exit devices or locks causing doors to remain electrically locked for a predetermined length of time (usually 15 seconds) after triggering the countdown timer. In other words, delayed egress locking systems are a device, or a combination of devices, arranged to be locked in the direction of egress travel, and intended to temporarily delay the egress of occupants.<\/p>\n<p>While a lock is not generally supposed to impede egress, there are specific situations where it may be necessary, as long as the application is in accordance with the relevant building or life safety code. For example, when used in healthcare facilities, delayed egress locks can alert staff to a patient attempting to leave the premises. Delayed egress locking systems may also be used in a retail setting to discourage shoplifting, or in schools and childcare centers to prevent abductions or delinquency. Delayed egress locks, in other words, operate like exit devices, yet provide the added safety and security in situations that may not be considered life-threatening.<\/p>\n<p>Over the last two editions of <em>IBC<\/em>, delayed egress locking systems have been permitted in new occupancy groups and, in some instances, more than one delayed egress locking system is permitted in the egress path. Since <em>IBC<\/em> has expanded where these systems are permitted to be used, they are now employed more widely; therefore, requiring compliance to ANSI\/BHMA A156.24 in the 2021 building codes can help assure these locking systems will function reliably and as they are intended time and time again.<\/p>\n<p><em>Door hardware single motion to egress<br \/>\n<\/em>According to <em>IBC<\/em> 1010.1.9.6, \u201cControlled egress door in Groups I-1 and I-2,\u201d \u201cthe unlatching of any door or leaf shall not require more than one operation.\u201d<\/p>\n<figure id=\"attachment_74813\" aria-describedby=\"caption-attachment-74813\" style=\"width: 239px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-43-PM.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-74813\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-43-PM.jpg\" alt=\"\" width=\"239\" height=\"321\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-43-PM.jpg 654w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-43-PM-223x300.jpg 223w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/11-7-2018-4-30-43-PM-372x500.jpg 372w\" sizes=\"auto, (max-width: 239px) 100vw, 239px\" \/><\/a><figcaption id=\"caption-attachment-74813\" class=\"wp-caption-text\">Door hardware standards play a significant role in life safety by ensuring products used in commercial and residential buildings are suitable for their intended use.<br \/><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\"><em>Photo courtesy Bigstockphoto.com<\/em><\/span><\/figcaption><\/figure>\n<p>Unfortunately, this language has code officials, specifiers, building owners, and security professions asking what is required of door hardware to meet the requirement for \u201cnot more than one operation\u201d to unlatch a door, and what is permitted. To address these questions, BHMA developed ANSI\/BHMA A156.41, <em>Standard for Door Hardware Single Motion to Egress<\/em>. It established requirements for hardware used on doors in the means of egress, to comply with code requirements for \u201cnot more than one operation\u201d to unlatch a door for egress. BHMA proposed <em>IBC<\/em> language be revised to \u201cthe unlatching of any door or leaf for egress shall not require more than one motion in a single linear or rotational direction to release all latching and all locking devices.\u201d<\/p>\n<p><strong>Conclusion<br \/>\n<\/strong>In today\u2019s connected world, there is a greater emphasis \u2028on building science and technology than ever before. New technologies and advances in building materials\u2014including builders hardware\u2014are occurring each year. As a result, building codes are also evolving to ensure the safety of building occupants and the public.<\/p>\n<p><em><span style=\"font-weight: 400;\">John Woestman is director of codes and government affairs for the Builders Hardware Manufacturers Association (BHMA). In this capacity, he provides building codes advocacy and technical service on behalf of BHMA. Woestman is a member of the International Code Council (ICC), the National Fire Prevention Association (NFPA), and ASTM International. He has represented BHMA\u2019s interests in ICC building codes development; NFPA codes and standards development; and ASTM standards development. Woestman has a mechanical engineering degree from Iowa State University and a MBA from the University of Iowa. He can be reached at <\/span><a href=\"mailto:JWoestman@kellencompany.com\"><span style=\"font-weight: 400;\">JWoestman@kellencompany.com<\/span><\/a><span style=\"font-weight: 400;\">. <\/span><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Door hardware standards play a significant role in life safety by ensuring products used in commercial and residential buildings are suitable for their intended use. These standards serve as tools for hardware manufacturers and building professionals by providing them with a mutual understanding of door hardware requirements and types of locking systems.<\/p>\n","protected":false},"author":11326,"featured_media":74811,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,179,449,188,278,491,460,502,462],"tags":[902,4839,2739,5088,5089,1198,555,1040,4818,5090,899,5091,4820],"class_list":["post-74809","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-masterformat","category-uniformat","category-08-00-00-openings","category-08-70-00-hardware","category-b2050exterior-doors-and-grilles","category-b20exterior-vertical-enclosures","category-c1030interior-doors","category-c10interior-construction","tag-08-71-00-door-hardware","tag-b2050-90-exterior-door-supplementary-components","tag-building-codes","tag-c1030-90-interior-door-supplementary","tag-components","tag-division-08","tag-door-hardware","tag-doors","tag-emergency-egress","tag-exit-devices","tag-life-safety","tag-locks","tag-panic-devices","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Cracking the code: Understanding the latest IBC revisions for builders hardware - The Construction Specifier<\/title>\n<meta name=\"description\" content=\"Door hardware standards play a significant role in safety by ensuring products in commercial and residential buildings are suitable for their intended use.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cracking the code: Understanding the latest IBC revisions for builders hardware - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Door hardware standards play a significant role in safety by ensuring products in commercial and residential buildings are suitable for their intended use.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2018-11-07T21:33:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2018-11-07T21:36:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/feat1-6.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sarah Said\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sarah Said\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/\"},\"author\":{\"name\":\"Sarah Said\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/7d4e77e17457d3438733da3abaa626b1\"},\"headline\":\"Cracking the code: Understanding the latest IBC revisions for builders hardware\",\"datePublished\":\"2018-11-07T21:33:21+00:00\",\"dateModified\":\"2018-11-07T21:36:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/\"},\"wordCount\":1727,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2018\\\/11\\\/feat1-6.jpg\",\"keywords\":[\"08 71 00\u2013Door Hardware\",\"B2050.90\u2013Exterior Door Supplementary Components\",\"Building Codes\",\"C1030.90\u2014Interior Door Supplementary\",\"Components\",\"Division 08\",\"Door hardware\",\"doors\",\"Emergency egress\",\"Exit devices\",\"Life safety\",\"Locks\",\"Panic devices\"],\"articleSection\":[\"Features\",\"MasterFormat\",\"UniFormat\",\"08 00 00 Openings\",\"08 70 00 Hardware\",\"B2050\u2212Exterior Doors and Grilles\",\"B20\u2212Exterior Vertical Enclosures\",\"C1030\u2212Interior Doors\",\"C10\u2212Interior Construction\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/\",\"name\":\"Cracking the code: Understanding the latest IBC revisions for builders hardware - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2018\\\/11\\\/feat1-6.jpg\",\"datePublished\":\"2018-11-07T21:33:21+00:00\",\"dateModified\":\"2018-11-07T21:36:28+00:00\",\"description\":\"Door hardware standards play a significant role in safety by ensuring products in commercial and residential buildings are suitable for their intended use.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2018\\\/11\\\/feat1-6.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2018\\\/11\\\/feat1-6.jpg\",\"width\":600,\"height\":300},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cracking the code: Understanding the latest IBC revisions for builders hardware\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/7d4e77e17457d3438733da3abaa626b1\",\"name\":\"Sarah Said\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce889938ec6d0d352bc138d6700d01fcfb8f966f41920aabfb49353c5be9a03?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce889938ec6d0d352bc138d6700d01fcfb8f966f41920aabfb49353c5be9a03?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bce889938ec6d0d352bc138d6700d01fcfb8f966f41920aabfb49353c5be9a03?s=96&d=mm&r=g\",\"caption\":\"Sarah Said\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/sarah_said\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cracking the code: Understanding the latest IBC revisions for builders hardware - The Construction Specifier","description":"Door hardware standards play a significant role in safety by ensuring products in commercial and residential buildings are suitable for their intended use.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/","og_locale":"en_US","og_type":"article","og_title":"Cracking the code: Understanding the latest IBC revisions for builders hardware - The Construction Specifier","og_description":"Door hardware standards play a significant role in safety by ensuring products in commercial and residential buildings are suitable for their intended use.","og_url":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/","og_site_name":"The Construction Specifier","article_published_time":"2018-11-07T21:33:21+00:00","article_modified_time":"2018-11-07T21:36:28+00:00","og_image":[{"width":600,"height":300,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/feat1-6.jpg","type":"image\/jpeg"}],"author":"Sarah Said","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Sarah Said","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/"},"author":{"name":"Sarah Said","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/7d4e77e17457d3438733da3abaa626b1"},"headline":"Cracking the code: Understanding the latest IBC revisions for builders hardware","datePublished":"2018-11-07T21:33:21+00:00","dateModified":"2018-11-07T21:36:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/"},"wordCount":1727,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/feat1-6.jpg","keywords":["08 71 00\u2013Door Hardware","B2050.90\u2013Exterior Door Supplementary Components","Building Codes","C1030.90\u2014Interior Door Supplementary","Components","Division 08","Door hardware","doors","Emergency egress","Exit devices","Life safety","Locks","Panic devices"],"articleSection":["Features","MasterFormat","UniFormat","08 00 00 Openings","08 70 00 Hardware","B2050\u2212Exterior Doors and Grilles","B20\u2212Exterior Vertical Enclosures","C1030\u2212Interior Doors","C10\u2212Interior Construction"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/","url":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/","name":"Cracking the code: Understanding the latest IBC revisions for builders hardware - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/feat1-6.jpg","datePublished":"2018-11-07T21:33:21+00:00","dateModified":"2018-11-07T21:36:28+00:00","description":"Door hardware standards play a significant role in safety by ensuring products in commercial and residential buildings are suitable for their intended use.","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/feat1-6.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/11\/feat1-6.jpg","width":600,"height":300},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/cracking-the-code-understanding-the-latest-ibc-revisions-for-builders-hardware\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"Cracking the code: Understanding the latest IBC revisions for builders hardware"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/7d4e77e17457d3438733da3abaa626b1","name":"Sarah Said","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/bce889938ec6d0d352bc138d6700d01fcfb8f966f41920aabfb49353c5be9a03?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bce889938ec6d0d352bc138d6700d01fcfb8f966f41920aabfb49353c5be9a03?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bce889938ec6d0d352bc138d6700d01fcfb8f966f41920aabfb49353c5be9a03?s=96&d=mm&r=g","caption":"Sarah Said"},"url":"https:\/\/www.constructionspecifier.com\/author\/sarah_said\/"}]}},"views":9511,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/74809","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/11326"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=74809"}],"version-history":[{"count":2,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/74809\/revisions"}],"predecessor-version":[{"id":74815,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/74809\/revisions\/74815"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/74811"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=74809"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=74809"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=74809"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}