{"id":78114,"date":"2018-12-28T15:29:26","date_gmt":"2018-12-28T20:29:26","guid":{"rendered":"https:\/\/www.constructionspecifier.com\/?p=78114"},"modified":"2018-12-28T15:29:26","modified_gmt":"2018-12-28T20:29:26","slug":"look-out-below","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/look-out-below\/","title":{"rendered":"Look out below"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-569 size-full\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/08\/slaton.jpg\" alt=\"slaton\" width=\"100\" height=\"104\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-571 alignleft\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2013\/08\/patterson.jpg\" alt=\"patterson\" width=\"100\" height=\"104\" \/> <span style=\"font-size: large;\"><strong><span style=\"color: #808080;\">FAILURES<\/span><\/strong><\/span><br \/>\n<strong>Deborah Slaton and David S. Patterson, AIA<\/strong><\/p>\n<p>The decision to replace an existing roof is often made in response to ongoing water leakage rather than as part of a proactive maintenance regimen, as owners and facility management companies attempt to obtain the last ounce of serviceability out of their building systems to manage cost. Unfortunately, such deferred maintenance can result in additional cost due to hidden damage to the underlying assembly caused by long-term exposure to water leakage or other conditions.<\/p>\n<figure id=\"attachment_78111\" aria-describedby=\"caption-attachment-78111\" style=\"width: 300px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-78111 size-medium\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2-300x225.jpg\" alt=\"Rafter pocket in brick mass wall (rafter removed), with severely deteriorated wood bearing plate engaged in the inner wythe of masonry. Photos \u00a9 David Patterson\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2-300x225.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2-768x576.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2-500x375.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-78111\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">Rafter pocket in brick mass wall (rafter removed), with severely deteriorated wood bearing plate engaged in the inner wythe of masonry. <br \/><em>Photos \u00a9 David Patterson<\/em><\/span><\/figcaption><\/figure>\n<p>While over-cladding an existing roof with a new assembly (rather than replacement) is common due to its perceived cost-effectiveness, it is understood this practice is ill-advised unless the condition of the existing roof assembly and supporting elements is known to be sound and dry\u2014a premise somewhat antithetical to a reroofing program necessitated by chronic leakage. Moisture within the assembly can become trapped below the new membrane and promote deterioration of the underlying components. Thermal effectiveness is also diminished when the insulation assembly is wet.<\/p>\n<figure id=\"attachment_78112\" aria-describedby=\"caption-attachment-78112\" style=\"width: 300px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-2-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-78112\" src=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-2-2-300x225.jpg\" alt=\"View of rafter pocket illustrated above after wood bearing plate was removed by hand. Note the deteriorated rafter end at the adjacent pocket.\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-2-2-300x225.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-2-2-768x576.jpg 768w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-2-2-500x375.jpg 500w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-2-2.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption id=\"caption-attachment-78112\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial, helvetica, sans-serif;\">View of rafter pocket illustrated above after wood bearing plate was removed by hand. Note the deteriorated rafter end at the adjacent pocket.<\/span><\/figcaption><\/figure>\n<p>In the example illustrated, the roof of a circa 1920s building is supported by wood tongue-and-groove decking, which, in turn, is supported by wood framing. At the perimeter of the roof, wood rafters are pocketed into the exterior multi-wythe mass masonry brick walls. While the initial decision by the project team was to roof over the existing assembly to reduce cost, an unrelated investigation revealed the wood rafters bear on a wood plate constructed as part of the masonry wall (taking the place of a course of brick at the inner wythe of the wall). It was discovered the wood bearing plate was severely damaged as a result of to long-term exposure to moisture\/water leakage and insect damage. This deterioration was so extensive, the plate was reduced to disconnected fibers that could be easily removed by the handful. Rafter ends and sections of wood decking were also damaged, calling their structural integrity into question. The weakening of the wood bearing plate then resulted in not only an inadequate support condition for the rafters, but also a loss of support of several courses of the inner brick wythe that now relied on the header brick to carry gravity loads.<\/p>\n<p>If it had not been for the unrelated investigation revealing the underlying conditions, a new roof would likely have been installed over the existing assembly, masking these conditions until they were discovered during the work, future inspection, or catastrophic failure. If distress conditions had not been found before installation of the new roof system, costs of the additional repairs required after the fact would likely have exceeded initial savings realized by the decision to over-roof.<\/p>\n<p><span style=\"color: #999999;\">The opinions expressed in Failures are based on the authors\u2019 experiences and do not necessarily reflect those of <em>The Construction Specifier<\/em> or CSI.<\/span><\/p>\n<p><em>Deborah Slaton is an architectural conservator and principal with Wiss, Janney, Elstner Associates (WJE) in Northbrook, Illinois, specializing in historic preservation and materials conservation. She can be reached at <a href=\"mailto:dslaton@wje.com\" target=\"_blank\" rel=\"noopener\">dslaton@wje.com<\/a>.<\/em><\/p>\n<p><em>David S. Patterson, AIA, is an architect and senior principal with WJE\u2019s office<\/em><br \/>\n<em> in Princeton, New Jersey. He specializes in investigation and repair of the building envelope. He can be reached at <a href=\"mailto:dpatterson@wje.com\" target=\"_blank\" rel=\"noopener\">dpatterson@wje.com<\/a>.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The decision to replace an existing roof is often made in response to ongoing water leakage rather than as part of a proactive maintenance regimen, as owners and facility management companies attempt to obtain the last ounce of serviceability out of their building systems to manage cost. Unfortunately, such deferred maintenance can result in additional cost.<\/p>\n","protected":false},"author":4183,"featured_media":78111,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9,24],"tags":[1035,80,113,534,2700,88,5201],"class_list":["post-78114","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-columns","category-failures","tag-brick","tag-failures-2","tag-masonry","tag-moisture-management","tag-roof-maintenance","tag-roofing-2","tag-wood-rafters","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Expanding on structural steel<\/title>\n<meta name=\"description\" content=\"The effects of corrosion on metal building components range from aesthetically undesirable appearances to hazardous structural conditions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/look-out-below\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Expanding on structural steel\" \/>\n<meta property=\"og:description\" content=\"The effects of corrosion on metal building components range from aesthetically undesirable appearances to hazardous structural conditions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/look-out-below\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2018-12-28T20:29:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"nithya_caleb\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"nithya_caleb\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/\"},\"author\":{\"name\":\"nithya_caleb\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/b98ef8acdc4f61ec3c542bdb863ee469\"},\"headline\":\"Look out below\",\"datePublished\":\"2018-12-28T20:29:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/\"},\"wordCount\":596,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/Photo-1-2.jpg\",\"keywords\":[\"brick\",\"failures\",\"Masonry\",\"Moisture management\",\"Roof maintenance\",\"roofing\",\"Wood rafters\"],\"articleSection\":[\"Columns\",\"Failures\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/\",\"name\":\"Expanding on structural steel\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/Photo-1-2.jpg\",\"datePublished\":\"2018-12-28T20:29:26+00:00\",\"description\":\"The effects of corrosion on metal building components range from aesthetically undesirable appearances to hazardous structural conditions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/Photo-1-2.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/Photo-1-2.jpg\",\"width\":800,\"height\":600,\"caption\":\"Rafter pocket in brick mass wall (rafter removed), with severely deteriorated wood bearing plate engaged in the inner wythe of masonry. Photos \u00a9 David Patterson\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/look-out-below\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Look out below\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/b98ef8acdc4f61ec3c542bdb863ee469\",\"name\":\"nithya_caleb\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8a720f16106e3badd15369daa30776863e73616618206dbee6511c6f2a993456?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8a720f16106e3badd15369daa30776863e73616618206dbee6511c6f2a993456?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8a720f16106e3badd15369daa30776863e73616618206dbee6511c6f2a993456?s=96&d=mm&r=g\",\"caption\":\"nithya_caleb\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/nithya_caleb\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Expanding on structural steel","description":"The effects of corrosion on metal building components range from aesthetically undesirable appearances to hazardous structural conditions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/look-out-below\/","og_locale":"en_US","og_type":"article","og_title":"Expanding on structural steel","og_description":"The effects of corrosion on metal building components range from aesthetically undesirable appearances to hazardous structural conditions.","og_url":"https:\/\/www.constructionspecifier.com\/look-out-below\/","og_site_name":"The Construction Specifier","article_published_time":"2018-12-28T20:29:26+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2.jpg","type":"image\/jpeg"}],"author":"nithya_caleb","twitter_card":"summary_large_image","twitter_misc":{"Written by":"nithya_caleb","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/"},"author":{"name":"nithya_caleb","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/b98ef8acdc4f61ec3c542bdb863ee469"},"headline":"Look out below","datePublished":"2018-12-28T20:29:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/"},"wordCount":596,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2.jpg","keywords":["brick","failures","Masonry","Moisture management","Roof maintenance","roofing","Wood rafters"],"articleSection":["Columns","Failures"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/look-out-below\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/","url":"https:\/\/www.constructionspecifier.com\/look-out-below\/","name":"Expanding on structural steel","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2.jpg","datePublished":"2018-12-28T20:29:26+00:00","description":"The effects of corrosion on metal building components range from aesthetically undesirable appearances to hazardous structural conditions.","breadcrumb":{"@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/look-out-below\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2018\/12\/Photo-1-2.jpg","width":800,"height":600,"caption":"Rafter pocket in brick mass wall (rafter removed), with severely deteriorated wood bearing plate engaged in the inner wythe of masonry. Photos \u00a9 David Patterson"},{"@type":"BreadcrumbList","@id":"https:\/\/www.constructionspecifier.com\/look-out-below\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.constructionspecifier.com\/"},{"@type":"ListItem","position":2,"name":"Look out below"}]},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/b98ef8acdc4f61ec3c542bdb863ee469","name":"nithya_caleb","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/8a720f16106e3badd15369daa30776863e73616618206dbee6511c6f2a993456?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8a720f16106e3badd15369daa30776863e73616618206dbee6511c6f2a993456?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8a720f16106e3badd15369daa30776863e73616618206dbee6511c6f2a993456?s=96&d=mm&r=g","caption":"nithya_caleb"},"url":"https:\/\/www.constructionspecifier.com\/author\/nithya_caleb\/"}]}},"views":8294,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/78114","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/4183"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=78114"}],"version-history":[{"count":1,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/78114\/revisions"}],"predecessor-version":[{"id":78117,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/78114\/revisions\/78117"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/78111"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=78114"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=78114"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=78114"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}