{"id":8907,"date":"2015-05-06T14:56:36","date_gmt":"2015-05-06T18:56:36","guid":{"rendered":"http:\/\/www.constructionspecifier.com\/?p=8907"},"modified":"2016-12-21T14:25:54","modified_gmt":"2016-12-21T19:25:54","slug":"using-vapor-retarders-to-manage-airflow-and-reduce-moisture","status":"publish","type":"post","link":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/","title":{"rendered":"Using vapor retarders to manage airflow and reduce moisture"},"content":{"rendered":"<figure id=\"attachment_8908\" aria-describedby=\"caption-attachment-8908\" style=\"width: 297px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8908 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383.png\" alt=\"airbarriers_membrain_SI_CertainTeed_5383\" width=\"297\" height=\"198\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383.png 480w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383-300x200.png 300w\" sizes=\"auto, (max-width: 297px) 100vw, 297px\" \/><\/a><figcaption id=\"caption-attachment-8908\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: 8pt;\">All images courtesy CertainTeed<\/span><\/figcaption><\/figure>\n<p><strong>by Ted Winslow<br \/>\n<\/strong>Industry codes are tightening the building envelope and increasing the required R-value of walls. This is a good thing for energy savings and thermal comfort. Yet, one change to a building\u2019s system sets forth a series of other changes.<\/p>\n<p>The tight-envelope construction techniques to which architects and builders are now required to adhere have led to a steep reduction in air movement through walls. This means moisture gets trapped inside wall cavities without sufficient means for it to escape, leading to reduced drying potential for a wall\u2019s interior. Therefore, the airtight standards for energy efficiency have created new challenges for moisture management that cannot be neglected. This \u2018moisture sandwich\u2019 is occurring with increasing frequency as architects design walls and incorporate newer insulation practices to enhance energy efficiency.<\/p>\n<p><strong>How moisture enters a building envelope<br \/>\n<\/strong>The first step is to understand how moisture penetrates wall assemblies. Generally, there are four forces driving moisture through the building envelope:<\/p>\n<ul>\n<li>gravity;<\/li>\n<li>capillary suction;<\/li>\n<li>water vapor diffusion; and<\/li>\n<li>airborne movement of water vapor.<\/li>\n<\/ul>\n<p>Gravity moves rainwater down a building\u2019s exterior surface. When there are openings in exterior wall assemblies, such as downward-sloped openings, water will pass through them. This force is typically countered by roof systems designed with shingles and flashings. Also, overlapping, sealing, or covering exterior wall joints in a manner that diverts rain from the building helps keep gravity-drawn water out of the wall.<\/p>\n<p>Another mechanism of water penetration is capillary suction, which is a result of the surface tension of water. Water is drawn inside through tiny pores in building materials, often so small they are invisible to the eye. To hinder this moisture flow mechanism, it is best to break the continuity of materials from the exterior through to the interior to obstruct moisture\u2019s path. Breaks in components can be accomplished by incorporating small cavities that prevent moisture from migrating through all the layers of materials. Specifying moisture-tolerant exterior wall materials like concrete and masonry is also helpful.<\/p>\n<p>A third way moisture enters a building envelope is through water vapor diffusion. Water vapor will pass or diffuse through building materials whenever areas of high and low vapor pressure exist on opposite sides of that material. This movement is from the material\u2019s high vapor pressure side to the low-pressure side.<\/p>\n<p>Water vapor permeance of a building material can be determined through ASTM E96, <em>Standard Test Methods for Water Vapor Transmission of Materials<\/em>, which measures diffusion using two possible means: the dry cup method (also known as Method A or the desiccant method) and the wet cup method (also referred to as Method B or the water method).<sup>1<\/sup><\/p>\n<figure id=\"attachment_8913\" aria-describedby=\"caption-attachment-8913\" style=\"width: 325px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_BlocksMoisture-ALT-v2-FA_text1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8913 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_BlocksMoisture-ALT-v2-FA_text1-e1430936763638.png\" alt=\"airbarriers_BlocksMoisture-ALT-v2-FA_text[1]\" width=\"325\" height=\"355\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_BlocksMoisture-ALT-v2-FA_text1-e1430936763638.png 467w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_BlocksMoisture-ALT-v2-FA_text1-e1430936763638-275x300.png 275w\" sizes=\"auto, (max-width: 325px) 100vw, 325px\" \/><\/a><figcaption id=\"caption-attachment-8913\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: 10pt;\">When humidity levels in the wall are low, a smart vapor retarder will prevent moisture from entering.<\/span><\/figcaption><\/figure>\n<p style=\"text-align: left;\">Air movement is yet another way moisture gets inside a building. In fact, air can bring a large amount of moisture into a building if it is not impeded by good construction practices. Compared to moisture entering a building by water vapor diffusion, moisture carried into a building by air can be up to 100 times greater. For example, a 1.2 x 2.4-m (4 x 8-ft) sheet of gypsum board will permit up to 285 ml (9.6 oz) of water to pass through it over a heating season in a cold climate. If, however, a 25-mm (1-in.) hole were to open in that board to permit airflow, airborne moisture flow could add up to 28 L (7.5 gal) of water over the same period. This phenomenon creates an excellent case for making wall assemblies airtight and preventing moisture from condensing on cold surfaces.<\/p>\n<p>Naturally, moisture can enter the cavity from either the inside or outside of the wall\u2014an average family of four can create two to three gallons of water vapor per day from cooking, bathing, and washing dishes and laundry. Over a heating season in colder climates, these moisture loads are driven toward a building\u2019s exterior and penetrate into the wall cavity. Air can transport moisture quantities up to 28 L through holes in the building envelope\u2019s interior side that are as small as 645.16 mm<sup>2<\/sup> (1 si). This has led to an increased focus on developing more airtight wall systems.<\/p>\n<p>While an airtight wall is important, there is need for a means of escape for moisture that gets trapped in the assembly. If there is no established escape plan, then the building has a high likelihood of creating a moisture sandwich inside its walls.<!--nextpage--><\/p>\n<figure id=\"attachment_8917\" aria-describedby=\"caption-attachment-8917\" style=\"width: 315px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_ReleasesMoisture-ALT-v2-FA_text1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8917\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_ReleasesMoisture-ALT-v2-FA_text1-e1430936989614.png\" alt=\"airbarriers_ReleasesMoisture-ALT-v2-FA_text[1]\" width=\"315\" height=\"339\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_ReleasesMoisture-ALT-v2-FA_text1-e1430936989614.png 472w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_ReleasesMoisture-ALT-v2-FA_text1-e1430936989614-279x300.png 279w\" sizes=\"auto, (max-width: 315px) 100vw, 315px\" \/><\/a><figcaption id=\"caption-attachment-8917\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: 10pt;\">When humidity levels in the wall increase, a smart vapor retarder becomes porous to let excess moisture escape<\/span>.<\/figcaption><\/figure>\n<p style=\"text-align: left;\"><strong>Making a moisture sandwich<br \/>\n<\/strong>A moisture sandwich occurs when a well-insulated wall system traps moisture from both the interior and exterior components. It is a scenario playing out with frequency as architects design walls and incorporate insulating products that create energy-efficient buildings. For example, many areas of the country are beginning to install exterior insulation to help increase a wall\u2019s R-value, decrease its thermal bridging, and reduce the permeance level.<\/p>\n<p>Extruded polystyrene (XPS) has a permeance level of .03, which is similar to 152.4-\u00b5m (6-mil) poly. A common assembly may comprise:<\/p>\n<ul>\n<li>moisture-retentive cladding like fiber cement, brick, or stucco;<\/li>\n<li>exterior insulation that acts as a vapor retarder similar to 152.4-\u00b5m polyethylene;<\/li>\n<li>oriented strandboard (OSB), which is semi-permeable at 2.0;<\/li>\n<li>kraft-faced fiberglass batts at a range of .3 to three or unfaced batts and 152.4\u00b5m polyethylene with a permeance rating of .05; and<\/li>\n<li>dryall with a permeance rating of three to 35, depending on the paint.<\/li>\n<\/ul>\n<p>Unfortunately, this creates a moisture sandwich: moisture gets into the wall and is trapped between polyisocyanurate (polyiso) foam board on the exterior, and a 152.4-\u00b5m polyethylene on the interior with no ability to dry. It is a probable situation that is likely under construction throughout the country at this moment.<\/p>\n<p><strong>Consequences of a moist wall<br \/>\n<\/strong>Having moved beyond the era of leaky buildings, the industry is now facing a new set of challenges stemming from this era of airtight construction. Moisture, when trapped inside a wall cavity for an extended period, can cause building materials like wood, traditional paper-faced gypsum, and steel to eventually deteriorate or corrode. Even R-value goes down when insulation gets moist, and thermal performance is the reason the wall system was constructed to be airtight in the first place.<\/p>\n<p>It is common knowledge moisture buildup can lead to health issues through mold growth that releases potentially harmful spores into the air. These airborne spores can cause occupants to experience acute health and comfort issues that correlate with the time they spend inside the building.<\/p>\n<p>Architects want to design wall systems that are able to dry; otherwise, these types of product deterioration scenarios and mold growth are likely. Since the moisture is within the wall, the issues are unlikely to be found until it is too late. This is when the large and expensive problems like mold remediation and litigation arise.<\/p>\n<p>It is possible to design a continuous airtight wall system that also exerts moisture control.<br \/>\nA great first step is to focus on the management of air and moisture flow through the building envelope. Continuous air barriers and smart vapor retarders are able to address both airflow and manage the moisture profile of the exterior wall cavity. This helps minimize and limit the risk of moisture-based building issues while adding minimal additional labor to projects.<\/p>\n<figure id=\"attachment_8922\" aria-describedby=\"caption-attachment-8922\" style=\"width: 321px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_Cti12PpkVapMb0001B.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8922 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_Cti12PpkVapMb0001B.png\" alt=\"airbarriers_Cti12PpkVapMb0001B\" width=\"321\" height=\"206\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_Cti12PpkVapMb0001B.png 480w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_Cti12PpkVapMb0001B-300x193.png 300w\" sizes=\"auto, (max-width: 321px) 100vw, 321px\" \/><\/a><figcaption id=\"caption-attachment-8922\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: 10pt;\">Smart vapor retarders with polyamide film allow excess moisture to escape from the wall cavities. <\/span><\/figcaption><\/figure>\n<p><strong>Changing the drying potential of a wall<br \/>\n<\/strong>Poly vapor retarders are part of the traditional approach to keeping moisture out of a wall, but as mentioned, moisture seems to find its way in, one way or another. Historically, building codes have classified vapor retarders as having a water vapor permeance of 1 perm or less when tested in accordance with the ASTM E96 desiccant\/dry cup method. As such, most products are only evaluated under dry conditions. Products like polyethylene film or aluminum foil have low permeance values that remain constant between dry and wet conditions.<\/p>\n<p>Rather than contributing to a healthy wall cavity, vapor retarders can often become part of the problem. These low-perm materials slow the rate of water vapor diffusion, but do not totally prevent its movement. As water vapor moves from a warm interior through construction materials to a cooler surface, the water vapor may condense on these vapor retarders as liquid water that could damage the building. It is for this reason smart vapor retarders are needed. Not only do they retard moisture penetration, but they also increase the potential for materials to dry. The wall\u2019s drying potential must always be greater than the wetting potential so the amount of moisture getting into the system is less than the amount of moisture that can leave it.<\/p>\n<p>Smart vapor retarders, though not required by code, are the better approach to a healthy wall assembly in many regions. Fortunately, building codes are continuing to evolve and adapt; it is important to use progressive solutions that also actively manage conditions within the wall assembly. Design professionals should strive to build beyond current practice\u2014selecting adaptive solutions like smart vapor retarders can be the better practice in various situations.<!--nextpage--><\/p>\n<figure id=\"attachment_8924\" aria-describedby=\"caption-attachment-8924\" style=\"width: 344px\" class=\"wp-caption alignleft\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_DOE_Map_only.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8924 \" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_DOE_Map_only.png\" alt=\"airbarriers_DOE_Map_only\" width=\"344\" height=\"213\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_DOE_Map_only.png 480w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_DOE_Map_only-300x186.png 300w\" sizes=\"auto, (max-width: 344px) 100vw, 344px\" \/><\/a><figcaption id=\"caption-attachment-8924\" class=\"wp-caption-text\"><span style=\"font-family: arial,helvetica,sans-serif; font-size: 10pt;\">Large portions of North America are considered mixed-climate regions, where the moisture drive direction is balanced between winter and summer. In these regions, buildings using traditional polyethylene vapor retarders may successfully keep moisture out of the cavity in the cold season, while essentially trapping it there during summer when the moisture drive reverses. <\/span><\/figcaption><\/figure>\n<p><strong>How smart vapor retarders work<br \/>\n<\/strong>A smart vapor retarder reacts to changes in relative humidity (RH) by altering its physical structure. During the winter, when relative humidity is low, it provides high resistance to vapor penetration from the interior. However, when the RH increases to 60 percent or above, its permeance dramatically increases, thus allowing water vapor to pass through, which facilitates the drying of building systems. The moisture building within the wall system is now able to move from the high-moisture concentration area and dry toward the assembly\u2019s interior.<\/p>\n<p>During conditions of low RH, a smart vapor retarder maintains its impermeable state to prevent moisture from migrating and then condensing within the wall system. However, as soon as the material comes into contact with moisture (<em>i.e.<\/em> 60 percent RH), it opens up and softens its structure to allow the polar water molecules to penetrate through. As a result, the smart vapor retarder pores through which further water molecules can penetrate, and the permeance increases to greater than 10 perms as tested in accordance with ASTM E96\u2019s wet cup method. When the air is humid in the summer, the moisture penetrates through the pores into the building interior, allowing building materials to dry out. If the relative humidity decreases, the pores close up again, and the smart vapor retarder then acts as a barrier to moisture. In the winter, the smart vapor retarder protects the building materials behind it from condensation.<\/p>\n<p><strong>Climate\u2019s role in specifying air barriers<br \/>\n<\/strong>Large portions of North America are considered \u2018mixed-climate\u2019 regions, where the moisture drive direction is balanced between winter and summer. In these regions, buildings using traditional polyethylene vapor retarders may successfully keep moisture out of the cavity in the cold season, while essentially trapping it there during summer when the moisture drive reverses. This problem is further exacerbated by the use of moisture-retaining cladding, such as masonry, fiber cement, and stucco, which release moisture into the building cavity.<\/p>\n<p>As such, for cold climates, vapor retarders are required for wall assemblies and should be placed at the wall\u2019s interior side. In heat-dominated climates, the vapor retarder should be placed at the building envelope\u2019s exterior. In most applications, vapor or air barriers should be installed over un-faced insulation before the drywall is installed. Again, smart vapor retarders are a good choice in these mixed-humidity climates because of their ability to adapt to the varying moisture conditions that occur throughout the year.<\/p>\n<figure id=\"attachment_8932\" aria-describedby=\"caption-attachment-8932\" style=\"width: 854px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/Untitled-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8932\" src=\"http:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/Untitled-1.jpg\" alt=\"\" width=\"854\" height=\"371\" srcset=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/Untitled-1.jpg 1024w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/Untitled-1-300x130.jpg 300w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/Untitled-1-1000x435.jpg 1000w, https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/Untitled-1-624x271.jpg 624w\" sizes=\"auto, (max-width: 854px) 100vw, 854px\" \/><\/a><figcaption id=\"caption-attachment-8932\" class=\"wp-caption-text\"><span style=\"font-size: 10pt; font-family: arial,helvetica,sans-serif;\">Many areas of the country are beginning to install exterior insulation. While this helps increase a wall\u2019s R-value, decrease thermal bridging, and reduce the wall\u2019s permeance level, it can also trap moisture within the walls. Popular cladding products like brick, stucco, and fiber cement hold moisture, which can also increase moisture buildup in walls.<\/span><\/figcaption><\/figure>\n<p>While smart vapor retarders can reduce the risk of moisture damage in the building envelope by increasing the construction\u2019s tolerance to moisture load, they are not suitable for every climate. Hot climates with high outdoor humidity are always under high RH conditions, which in turn, would cause<br \/>\na smart vapor retarder to always be permeable and never provide the wall cavity with vapor retarding benefits. These materials also do not work well in buildings with exceptionally high, constant indoor humidity levels, such as indoor pools and spas. However, in rooms with short peaks of high humidity like restrooms and kitchens, the performance of the smart vapor retarder would not be affected because of the buffering action of interior finishes.<\/p>\n<p><strong>Conclusion<\/strong><br \/>\nA holistic approach to building design is the best way to address moisture and air flow. As architects and builders affect one area like thermal performance, the flow of air and moisture are also impacted. Moisture in the wall is unavoidable, so it is important assemblies are designed with the potential to dry. By incorporating adaptable solutions like smart vapor retarders, occupant comfort can be managed and buildings set up for long-term structural success.<\/p>\n<p><em>Ted Winslow is product manager, building science, systems, and technical marketing for CertainTeed Insulation. He serves the company as a technical resource on topics ranging from code reviews to sustainability programs and oversees development of CertainTeed insulation systems. Winslow holds a bachelor\u2019s of science degree in mechanical engineering from Temple University. He can be reached at <a title=\"ted.winslow@saint-gobain.com\" href=\"mailto:ted.winslow@saint-gobain.com\" target=\"_blank\">ted.winslow@saint-gobain.com<\/a>.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Industry codes are tightening the building envelope and increasing the required R-value of walls. This is a good thing for energy savings and thermal comfort. <\/p>\n","protected":false},"author":5,"featured_media":8908,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[520,179,449,187,264,489,460],"tags":[1319,780,150,66,1195,67,1114,1542],"class_list":["post-8907","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-features","category-masterformat","category-uniformat","category-07-00-00-thermal-and-moisture-protection","category-07-20-00-thermal-protection","category-b2010exterior-walls","category-b20exterior-vertical-enclosures","tag-07-26-00-vapor-retarders","tag-07-27-00-air-barriers","tag-air-barrier","tag-building-envelope","tag-division-07","tag-moisture","tag-vapor-retarder","tag-wall-cavity","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Using vapor retarders to manage airflow and reduce moisture - The Construction Specifier<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/\" \/>\n<link rel=\"next\" href=\"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Using vapor retarders to manage airflow and reduce moisture - The Construction Specifier\" \/>\n<meta property=\"og:description\" content=\"Industry codes are tightening the building envelope and increasing the required R-value of walls. This is a good thing for energy savings and thermal comfort.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/\" \/>\n<meta property=\"og:site_name\" content=\"The Construction Specifier\" \/>\n<meta property=\"article:published_time\" content=\"2015-05-06T18:56:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-12-21T19:25:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383.png\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"320\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Katie Daniel\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Katie Daniel\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/\"},\"author\":{\"name\":\"Katie Daniel\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/34e59e3f0bf081d4b975ae9b2c1764f3\"},\"headline\":\"Using vapor retarders to manage airflow and reduce moisture\",\"datePublished\":\"2015-05-06T18:56:36+00:00\",\"dateModified\":\"2016-12-21T19:25:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/\"},\"wordCount\":2353,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/airbarriers_membrain_SI_CertainTeed_5383.png\",\"keywords\":[\"07 26 00 Vapor Retarders\",\"07 27 00\u2013Air Barriers\",\"air barrier\",\"building envelope\",\"Division 07\",\"moisture\",\"Vapor retarder\",\"Wall Cavity\"],\"articleSection\":[\"Features\",\"MasterFormat\",\"UniFormat\",\"07 00 00 Thermal and Moisture Protection\",\"07 20 00 Thermal Protection\",\"B2010\u2212Exterior Walls\",\"B20\u2212Exterior Vertical Enclosures\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/\",\"name\":\"Using vapor retarders to manage airflow and reduce moisture - The Construction Specifier\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/airbarriers_membrain_SI_CertainTeed_5383.png\",\"datePublished\":\"2015-05-06T18:56:36+00:00\",\"dateModified\":\"2016-12-21T19:25:54+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/airbarriers_membrain_SI_CertainTeed_5383.png\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/airbarriers_membrain_SI_CertainTeed_5383.png\",\"width\":480,\"height\":320},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#website\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"name\":\"The Construction Specifier\",\"description\":\"Solutions for the Construction Industry\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.constructionspecifier.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#organization\",\"name\":\"The Construction Specifier\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"contentUrl\":\"https:\\\/\\\/www.constructionspecifier.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/CS_Logo_BW_LR.jpg\",\"width\":288,\"height\":70,\"caption\":\"The Construction Specifier\"},\"image\":{\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.constructionspecifier.com\\\/#\\\/schema\\\/person\\\/34e59e3f0bf081d4b975ae9b2c1764f3\",\"name\":\"Katie Daniel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g\",\"caption\":\"Katie Daniel\"},\"url\":\"https:\\\/\\\/www.constructionspecifier.com\\\/author\\\/katie-daniel\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Using vapor retarders to manage airflow and reduce moisture - The Construction Specifier","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/","next":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/2\/","og_locale":"en_US","og_type":"article","og_title":"Using vapor retarders to manage airflow and reduce moisture - The Construction Specifier","og_description":"Industry codes are tightening the building envelope and increasing the required R-value of walls. This is a good thing for energy savings and thermal comfort.","og_url":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/","og_site_name":"The Construction Specifier","article_published_time":"2015-05-06T18:56:36+00:00","article_modified_time":"2016-12-21T19:25:54+00:00","og_image":[{"width":480,"height":320,"url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383.png","type":"image\/png"}],"author":"Katie Daniel","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Katie Daniel","Est. reading time":"12 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/#article","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/"},"author":{"name":"Katie Daniel","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/34e59e3f0bf081d4b975ae9b2c1764f3"},"headline":"Using vapor retarders to manage airflow and reduce moisture","datePublished":"2015-05-06T18:56:36+00:00","dateModified":"2016-12-21T19:25:54+00:00","mainEntityOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/"},"wordCount":2353,"commentCount":0,"publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383.png","keywords":["07 26 00 Vapor Retarders","07 27 00\u2013Air Barriers","air barrier","building envelope","Division 07","moisture","Vapor retarder","Wall Cavity"],"articleSection":["Features","MasterFormat","UniFormat","07 00 00 Thermal and Moisture Protection","07 20 00 Thermal Protection","B2010\u2212Exterior Walls","B20\u2212Exterior Vertical Enclosures"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/","url":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/","name":"Using vapor retarders to manage airflow and reduce moisture - The Construction Specifier","isPartOf":{"@id":"https:\/\/www.constructionspecifier.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/#primaryimage"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/#primaryimage"},"thumbnailUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383.png","datePublished":"2015-05-06T18:56:36+00:00","dateModified":"2016-12-21T19:25:54+00:00","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/using-vapor-retarders-to-manage-airflow-and-reduce-moisture\/#primaryimage","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383.png","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2015\/05\/airbarriers_membrain_SI_CertainTeed_5383.png","width":480,"height":320},{"@type":"WebSite","@id":"https:\/\/www.constructionspecifier.com\/#website","url":"https:\/\/www.constructionspecifier.com\/","name":"The Construction Specifier","description":"Solutions for the Construction Industry","publisher":{"@id":"https:\/\/www.constructionspecifier.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.constructionspecifier.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.constructionspecifier.com\/#organization","name":"The Construction Specifier","url":"https:\/\/www.constructionspecifier.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","contentUrl":"https:\/\/www.constructionspecifier.com\/wp-content\/uploads\/2017\/09\/CS_Logo_BW_LR.jpg","width":288,"height":70,"caption":"The Construction Specifier"},"image":{"@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.constructionspecifier.com\/#\/schema\/person\/34e59e3f0bf081d4b975ae9b2c1764f3","name":"Katie Daniel","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/61581f197b5eb954385d63e8f4a68b6624a13223539469ba68b02582f220045a?s=96&d=mm&r=g","caption":"Katie Daniel"},"url":"https:\/\/www.constructionspecifier.com\/author\/katie-daniel\/"}]}},"views":16087,"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/8907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/comments?post=8907"}],"version-history":[{"count":20,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/8907\/revisions"}],"predecessor-version":[{"id":23646,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/posts\/8907\/revisions\/23646"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media\/8908"}],"wp:attachment":[{"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/media?parent=8907"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/categories?post=8907"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.constructionspecifier.com\/wp-json-v2\/wp\/v2\/tags?post=8907"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}