Whether field or shop fabricated, one quality control measure to confirm the integrity and consistency of the structural sealant application is to deglaze representative assemblies—deglazing representative assemblies also assists in developing protocols for infill replacement should the infill be damaged in-service.
+ Read More
|
Prior to the adoption of the 2015 International Building Code (IBC), vents were required in the roof assembly to allow the “attic” space—between the underside of the roof deck and the top of the ceiling below—to vent to the exterior. However, the volume of air movement provided by these...
+ Read More
|
When through-wall flashing is not properly detailed or installed in cavity wall construction, the water penetration resistance of the enclosure can be compromised. This was recently observed at a multi-story office building in the southeastern U.S., that regularly experienced water leakage during prolonged rain events above ribbon window assemblies.
+ Read More
|
Regardless of the exact cause, this failure points to the importance of understanding the substrate condition prior to coating application.
+ Read More
|
In 2022, the authors collaborated with researchers at the University of Massachusetts, Ajla Aksamija, PhD, and Suncica Milosevic, to quantify the potential for condensation on a variety of window systems. Eleven different aluminum architectural window systems spanning a wide range of heat transfer coefficients (U-factors) and CR ratings were...
+ Read More
|
In the absence of a large-scale fire catastrophe, a sense of complacency may be influencing the specification of firestopping materials. In recent years, North America has seen a trend of pre-insulated back pans coming from overseas which contain foreign mineral wool that has not been tested to ASTM E2307....
+ Read More
|
A close-range examination revealed the gaskets were not driven to the required depth within the joints to engage the locking barb with the corresponding raceway in the outboard aluminum trim. Instead, they were retained in the joint through compression alone, leaving them susceptible to disengagement over time.
+ Read More
|
PT tendons are susceptible to corrosion from water and chloride (salt) ingress in similar ways as conventional reinforcing steel. However, unlike conventionally reinforced concrete, the effects of corrosion can result in the tendons losing tension and the concrete losing pre-compression.
+ Read More
|
Considering GPTP is a relatively thin material compared to its overall dimension, its units are subject to bending fracture during movement and setting and, as such, require a suction-cupped frame for proper handling.
+ Read More
|
In the front of house, which includes public-facing areas such as the dining room, bar, and reception area, visual aesthetics are of primary importance, including the ceiling ... In the back of house, comprising the kitchen and other food preparation areas and stations, hygiene and cleanability are key requirements.
+ Read More
|
|
|